BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 24756274)

  • 21. Dilation-assisted transpapillary alligator forceps retrieval of a fully covered self-expanding metal stent with long-term migration.
    Zimmer V
    Kaohsiung J Med Sci; 2020 Sep; 36(9):761-762. PubMed ID: 32542999
    [No Abstract]   [Full Text] [Related]  

  • 22. Triple Covered Metal Stent Deployment Using Side-by-Side Technique for Hemobilia due to Hepatocellular Carcinoma (with Video).
    Ogura T; Yamada T; Yamada M; Ueno S; Higuchi K
    Dig Dis; 2020; 38(4):348-351. PubMed ID: 31830747
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A case of hemobilia caused by pancreatic metastasis of renal cell carcinoma treated with a covered metallic stent.
    Yamawaki M; Takano Y; Noda J; Azami T; Kobayashi T; Niiya F; Maruoka N; Yamagami T; Nagahama M
    Clin J Gastroenterol; 2022 Feb; 15(1):210-215. PubMed ID: 34637048
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Transpapillary biopsies and brush cytology from the common bile duct.
    Aabakken L; Kåresen R; Serck-Hanssen A; Osnes M
    Endoscopy; 1986 Mar; 18(2):49-51. PubMed ID: 3956437
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The role of covered self-expandable metallic stents in malignant biliary strictures.
    Leung J; Rahim N
    Gastrointest Endosc; 2006 Jun; 63(7):1001-3. PubMed ID: 16733116
    [No Abstract]   [Full Text] [Related]  

  • 26. Small arteriovenous malformation of the common bile duct causing hemobilia in a patient with hereditary hemorrhagic telangiectasia.
    Hayashi S; Baba Y; Ueno K; Nakajo M
    Cardiovasc Intervent Radiol; 2008 Jul; 31 Suppl 2():S131-4. PubMed ID: 18027022
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Expandable metallic stents for benign pancreaticbiliary disease: clinical benefit or endoscopist's anxiety?
    Scutz SM; Baillie J
    Am J Gastroenterol; 1995 Feb; 90(2):326-7. PubMed ID: 7847316
    [No Abstract]   [Full Text] [Related]  

  • 28. Clinical outcome of simultaneous self-expandable metal stents for palliation of malignant biliary and duodenal obstruction.
    Kaw M; Singh S; Gagneja H
    Surg Endosc; 2003 Mar; 17(3):457-61. PubMed ID: 12404053
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Implantation of covered self-expandable metal stent in the common bile duct for the treatment of choledochoduodenal fistula.
    Zhao S; Wang J; Ge J; Zhang X; Liu J; Zhang A; Wang H
    J Clin Gastroenterol; 2014 Apr; 48(4):383-4. PubMed ID: 24518800
    [No Abstract]   [Full Text] [Related]  

  • 30. Fully covered self-expandable metal stents are effective and safe to treat distal malignant biliary strictures, irrespective of surgical resectability status.
    Siddiqui AA; Mehendiratta V; Loren D; Hong SK; Kowalski T
    J Clin Gastroenterol; 2011 Oct; 45(9):824-7. PubMed ID: 21921846
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The usefulness of endoscopic transpapillary procedure in post-cholecystectomy bile duct stricture and post-cholecystectomy bile leakage.
    Sakai Y; Tsuyuguchi T; Ishihara T; Sugiyama H; Miyakawa K; Yukisawa S; Yasui S; Eto R; Fujimoto T; Kaiho T; Miyazaki M; Yokosuka O
    Hepatogastroenterology; 2009; 56(93):978-83. PubMed ID: 19760924
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Endoscopic transpapillary biopsy for diagnosis of patients with pancreaticobiliary ductal strictures.
    Kubota Y; Takaoka M; Tani K; Ogura M; Kin H; Fujimura K; Mizuno T; Inoue K
    Am J Gastroenterol; 1993 Oct; 88(10):1700-4. PubMed ID: 8213710
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Efficacy and safety of self-expandable metal stents for biliary decompression in patients receiving neoadjuvant therapy for pancreatic cancer: a prospective study.
    Aadam AA; Evans DB; Khan A; Oh Y; Dua K
    Gastrointest Endosc; 2012 Jul; 76(1):67-75. PubMed ID: 22483859
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A prospective randomized study comparing partially covered metal stent versus plastic multistent in the endoscopic management of patients with postoperative benign bile duct strictures: a follow-up above 5 years.
    Artifon EL; Coelho F; Frazao M; Marques S; Paione JB; Takada J; Boaventura P; Rebello C; Pinhata Otoch J
    Rev Gastroenterol Peru; 2012; 32(1):26-31. PubMed ID: 22476175
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A prospective, randomized, controlled trial of metal stents for malignant obstruction of the common bile duct.
    Knyrim K; Wagner HJ; Pausch J; Vakil N
    Endoscopy; 1993 Mar; 25(3):207-12. PubMed ID: 8519239
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Malignant biliary obstruction: histologic findings after treatment with self-expandable stents.
    Hausegger KA; Kleinert R; Lammer J; Klein GE; Flückiger F
    Radiology; 1992 Nov; 185(2):461-4. PubMed ID: 1410354
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Use of a partially covered self-expandable metallic stent to treat a biliary stricture secondary to chronic pancreatitis complicated by recurrent cholangitis: a case report.
    Okabe Y; Ishida Y; Sasaki Y; Ushijima T; Sugiyama G; Tsuruta O
    Dig Endosc; 2012 May; 24 Suppl 1():55-8. PubMed ID: 22533753
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Meta-analysis of randomized trials comparing the patency of covered and uncovered self-expandable metal stents for palliation of distal malignant bile duct obstruction.
    Saleem A; Leggett CL; Murad MH; Baron TH
    Gastrointest Endosc; 2011 Aug; 74(2):321-327.e1-3. PubMed ID: 21683354
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Self-expandable metal mesh stents for common bile duct stenosis in chronic pancreatitis: retrospective evaluation of long-term follow-up and clinical outcome pilot study.
    Eickhoff A; Jakobs R; Leonhardt A; Eickhoff JC; Riemann JF
    Z Gastroenterol; 2003 Jul; 41(7):649-54. PubMed ID: 12908456
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Transhepatic contemporary palliation of biliary and duodenal stenoses by means of metallic stents.
    Cozzi G; Chiaraviglio F; Bonfanti G; Civelli EM
    Abdom Imaging; 2004; 29(6):688-90. PubMed ID: 15162234
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.