These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 24759216)

  • 1. [Winston-lutz test and acquisition of flexmap using rotational irradiation].
    Imae T; Haga A; Saotome N; Takenaka S; Okano Y; Sasaki K; Nedu M; Saegusa S; Shiraki T; Yano K; Nakagawa K; Ohtomo K
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2014 Apr; 70(4):359-68. PubMed ID: 24759216
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SU-E-J-33: Geometric Agreement Check for Imaging System with Radiation Beam by KV and MV-CBCT.
    Saotome N; Kida S; Haga A; Masutani Y; Ohtomo K; Nakagawa K
    Med Phys; 2012 Jun; 39(6Part6):3659. PubMed ID: 28517564
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).
    Anvari A; Poirier Y; Sawant A
    Med Phys; 2018 Jul; 45(7):3246-3257. PubMed ID: 29704440
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comprehensive geometric quality assurance framework for preclinical microirradiators.
    Anvari A; Poirier Y; Sawant A
    Med Phys; 2019 Apr; 46(4):1840-1851. PubMed ID: 30656713
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Off-iso Winston-Lutz test on seven linear accelerators.
    Gao J; Anand D
    J Appl Clin Med Phys; 2024 Jul; ():e14470. PubMed ID: 39042435
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A study of Winston-Lutz test on two different electronic portal imaging devices and with low energy imaging.
    Ravindran PB
    Australas Phys Eng Sci Med; 2016 Sep; 39(3):677-85. PubMed ID: 27435984
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy.
    Tsai JS; Micaily B; Miyamoto C
    Med Dosim; 2012; 37(3):321-33. PubMed ID: 22417899
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simple quality assurance based on filtered back projection for geometrical/irradiation accuracy in single-isocenter multiple-target stereotactic radiotherapy.
    Hayashi N; Kurata S; Saito Y; Ogawa S; Yasui K
    Radiol Phys Technol; 2022 Dec; 15(4):409-416. PubMed ID: 36261754
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Development of an automated method for analysis of Winston-Lutz test results using digital radiography and photostimulable storage phosphor].
    Nagafuchi K; Kawata H; Nashiki K; Ohkura S; Hayashida K; Kawahara T; Ohishi A; Mizoguchi A; Saida Y
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2013 Nov; 69(11):1266-73. PubMed ID: 24256650
    [TBL] [Abstract][Full Text] [Related]  

  • 10. SU-E-T-133: Isocenter Measurements with the Winston-Lutz Test: Impact on Treatment Planning.
    Templeton A; Chu J; Turian J
    Med Phys; 2012 Jun; 39(6Part11):3733-3734. PubMed ID: 28517166
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Positions of radiation isocenter and the couch rotation center established by Winston-Lutz and optical measurements.
    Jursinic P; Jordan K; Chen C
    Tech Innov Patient Support Radiat Oncol; 2022 Mar; 21():46-50. PubMed ID: 35243044
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel verification method using a plastic scintillator imagining system for assessment of gantry sag in radiotherapy.
    Tsuneda M; Nishio T; Saito A; Tanaka S; Suzuki T; Kawahara D; Matsushita K; Nishio A; Ozawa S; Karasawa K; Nagata Y
    Med Phys; 2018 Jun; 45(6):2411-2424. PubMed ID: 29663431
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Alignment of multiradiation isocenters for megavoltage photon beam.
    Zhang Y; Ding K; Cowan G; Tryggestad E; Armour E; Wang KK
    J Appl Clin Med Phys; 2015 Nov; 16(6):314-324. PubMed ID: 26699586
    [TBL] [Abstract][Full Text] [Related]  

  • 14. EXACTRAC x-ray and beam isocenters-what's the difference?
    Tideman Arp D; Carl J
    Med Phys; 2012 Mar; 39(3):1418-23. PubMed ID: 22380374
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator.
    Riis HL; Zimmermann SJ; Hjelm-Hansen M
    Med Phys; 2013 Mar; 40(3):031707. PubMed ID: 23464302
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Semi-automated IGRT QA using a cone-shaped scintillator screen detector for proton pencil beam scanning treatments.
    Cai W; Oesten H; Clasie B; Winey B; Jee KW
    Phys Med Biol; 2019 Apr; 64(8):085004. PubMed ID: 30736026
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Quality assurance procedure for assessing mechanical accuracy of a radiation field center in stereotactic radiotherapy].
    Tatsumi D; Ienaga A; Nakada R; Yomoda A; Inoue M; Ichida T; Hosono M
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2012; 68(10):1333-9. PubMed ID: 23089835
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quality assurance of geometric accuracy based on an electronic portal imaging device and log data analysis for Dynamic WaveArc irradiation.
    Hirashima H; Miyabe Y; Nakamura M; Mukumoto N; Mizowaki T; Hiraoka M
    J Appl Clin Med Phys; 2018 May; 19(3):234-242. PubMed ID: 29633542
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A simple method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter.
    Du W; Yang J; Luo D; Martel M
    Med Phys; 2010 May; 37(5):2256-63. PubMed ID: 20527559
    [TBL] [Abstract][Full Text] [Related]  

  • 20. On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests.
    Du W; Johnson JL; Jiang W; Kudchadker RJ
    J Appl Clin Med Phys; 2016 Jan; 17(1):167-178. PubMed ID: 26894350
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.