These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 24759216)

  • 21. Quality control methods for linear accelerator radiation and mechanical axes alignment.
    Létourneau D; Keller H; Becker N; Amin MN; Norrlinger B; Jaffray DA
    Med Phys; 2018 Jun; 45(6):2388-2398. PubMed ID: 29645282
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Initial application of a geometric QA tool for integrated MV and kV imaging systems on three image guided radiotherapy systems.
    Mao W; Speiser M; Medin P; Papiez L; Solberg T; Xing L
    Med Phys; 2011 May; 38(5):2335-41. PubMed ID: 21776767
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Remote Cherenkov imaging-based quality assurance of a magnetic resonance image-guided radiotherapy system.
    Andreozzi JM; Mooney KE; Brůža P; Curcuru A; Gladstone DJ; Pogue BW; Green O
    Med Phys; 2018 Jun; 45(6):2647-2659. PubMed ID: 29663429
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A novel-integrated quality assurance phantom for radiographic and nonradiographic radiotherapy localization and positioning systems.
    Yu AS; Fowler TL; Dubrowski P
    Med Phys; 2018 Jul; 45(7):2857-2863. PubMed ID: 29730884
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of three different phantoms used for Winston-Lutz test with Artiscan software.
    Szweda H; Graczyk K; Radomiak D; Matuszewski K; Pawałowski B
    Rep Pract Oncol Radiother; 2020; 25(3):351-354. PubMed ID: 32214910
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pixel response-based EPID dosimetry for patient specific QA.
    Han B; Ding A; Lu M; Xing L
    J Appl Clin Med Phys; 2017 Jan; 18(1):9-17. PubMed ID: 28291939
    [TBL] [Abstract][Full Text] [Related]  

  • 27. SU-E-J-49: Reliability Study of ExacTrac- System Image Isocenter Using an On-Demand QA Procedure.
    Wang X; Zhao Z; Du W; Li X; Yang J
    Med Phys; 2012 Jun; 39(6Part6):3663. PubMed ID: 28517561
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A new concept for verifying the isocentric alignment of the proton-rotational gantry for radiation control.
    Kato T; Yamazaki Y; Sagara T
    Radiol Phys Technol; 2020 Mar; 13(1):45-51. PubMed ID: 31707547
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Accuracy of positional correction for the floor-mounted kV X-ray IGRT system in angled couch positions.
    Koubuchi S; Takakura T; Nakamura M; Mizowaki T; Nakata M; Hiraoka M
    Radiol Phys Technol; 2014 Jul; 7(2):373-8. PubMed ID: 24925088
    [TBL] [Abstract][Full Text] [Related]  

  • 30. TU-E-BRB-11: End-To-End Positioning Quality Assurance for Image-Guided Radiosurgery of Multiple Targets Using a Single-Isocenter.
    Popple R; Fiveash J; Duan J; Wu X; Shen S; Cardan R; Brezovich I
    Med Phys; 2012 Jun; 39(6Part24):3910. PubMed ID: 28518657
    [TBL] [Abstract][Full Text] [Related]  

  • 31. SU-E-T-88: Evaluating Gantry Sag on Linear Accelerators and Introducing an MLC-Based Compensation Strategy.
    Du W; Gao S; Wang X; Kudchadker R
    Med Phys; 2012 Jun; 39(6Part11):3722-3723. PubMed ID: 28517157
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Automatic measurement of beam-positioning accuracy at off-isocenter positions.
    Ono T; Kido T; Nakamura M; Iramina H; Kakino R; Mizowaki T
    J Appl Clin Med Phys; 2023 Mar; 24(3):e13844. PubMed ID: 36420973
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Development of a Phantom and Analysis Program for Assessment of Positional Accuracy of Image-guided Radiation Therapy].
    Hayashi K; Miura H; Ozawa S; Habara K; Kawakubo A; Nakao M; Okumura T; Kunimoto H; Yamada K; Nozaki H; Nagata Y
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2024 Feb; 80(2):207-215. PubMed ID: 38148020
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery.
    Rowshanfarzad P; Sabet M; O'Connor DJ; Greer PB
    Med Phys; 2011 Jul; 38(7):3963-70. PubMed ID: 21858993
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A Method to Determine the Coincidence of MRI-Guided Linac Radiation and Magnetic Isocenters.
    Latifi K; Moros EG; Zhang G; Harrison L; Feygelman V
    Technol Cancer Res Treat; 2019 Jan; 18():1533033819877986. PubMed ID: 31537173
    [TBL] [Abstract][Full Text] [Related]  

  • 36. DeepWL: Robust EPID based Winston-Lutz analysis using deep learning, synthetic image generation and optical path-tracing.
    Douglass MJJ; Keal JA
    Phys Med; 2021 Sep; 89():306-316. PubMed ID: 34492498
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.
    Baker SJ; Budgell GJ; MacKay RI
    Phys Med Biol; 2005 Apr; 50(7):1377-92. PubMed ID: 15798330
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Independent verification of gantry angle for pre-treatment VMAT QA using EPID.
    Adamson J; Wu Q
    Phys Med Biol; 2012 Oct; 57(20):6587-600. PubMed ID: 23010739
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Image-guided total-body irradiation with a movable electronic portal imaging device for bone marrow transplant conditioning.
    Dipasquale G; Miralbell R; Lamanna G; Nouet P; Montero M; Rouzaud M; Zilli T
    Z Med Phys; 2020 May; 30(2):148-154. PubMed ID: 31787455
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A novel phantom and procedure providing submillimeter accuracy in daily QA tests of accelerators used for stereotactic radiosurgery*.
    Brezovich IA; Popple RA; Duan J; Shen S; Wu X; Benhabib S; Huang M; Cardan RA
    J Appl Clin Med Phys; 2016 Jul; 17(4):246-253. PubMed ID: 27455506
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.