These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 24763216)

  • 1. Calibration-free pulse oximetry based on two wavelengths in the infrared - a preliminary study.
    Nitzan M; Noach S; Tobal E; Adar Y; Miller Y; Shalom E; Engelberg S
    Sensors (Basel); 2014 Apr; 14(4):7420-34. PubMed ID: 24763216
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulse Oximetry with Two Infrared Wavelengths without Calibration in Extracted Arterial Blood.
    Yossef Hay O; Cohen M; Nitzan I; Kasirer Y; Shahroor-Karni S; Yitzhaky Y; Engelberg S; Nitzan M
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30326552
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vivo investigation of ear canal pulse oximetry during hypothermia.
    Budidha K; Kyriacou PA
    J Clin Monit Comput; 2018 Feb; 32(1):97-107. PubMed ID: 28130679
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.
    Abay TY; Kyriacou PA
    J Clin Monit Comput; 2018 Jun; 32(3):447-455. PubMed ID: 28547651
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-wavelength technique for the measurement of oxygen saturation in arterial blood and in venous blood.
    Nitzan M; Engelberg S
    J Biomed Opt; 2009; 14(2):024046. PubMed ID: 19405774
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pulse oximetry based on photoplethysmography imaging with red and green light : Calibratability and challenges.
    Moço A; Verkruysse W
    J Clin Monit Comput; 2021 Feb; 35(1):123-133. PubMed ID: 31893325
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    J Clin Monit Comput; 2011 Aug; 25(4):245-55. PubMed ID: 21953382
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers.
    Shafique M; Kyriacou PA
    Physiol Meas; 2012 Dec; 33(12):2065-78. PubMed ID: 23171523
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.
    Shafique M; Kyriacou PA; Pal SK
    Med Biol Eng Comput; 2012 Jun; 50(6):575-83. PubMed ID: 22555629
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase.
    Elron E; Bromiker R; Gleisner O; Yosef-Hai O; Goldberg O; Nitzan I; Nitzan M
    Sensors (Basel); 2023 Jan; 23(3):. PubMed ID: 36772474
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Attempt of a novel calibration method of pulse oximetry using support vector machines regression.
    Ogawa M; Yamakoshi Y; Nogawa M; Yamakoshi T; Motoi K; Tanaka S; Yamakoshi K
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():1485-8. PubMed ID: 19963505
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Posture effects on the calibratability of remote pulse oximetry in visible light.
    Moço A; Stuijk S; de Haan G
    Physiol Meas; 2019 Apr; 40(3):035005. PubMed ID: 30731445
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pulse oximetry: fundamentals and technology update.
    Nitzan M; Romem A; Koppel R
    Med Devices (Auckl); 2014; 7():231-9. PubMed ID: 25031547
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Noncontact simultaneous dual wavelength photoplethysmography: a further step toward noncontact pulse oximetry.
    Humphreys K; Ward T; Markham C
    Rev Sci Instrum; 2007 Apr; 78(4):044304. PubMed ID: 17477684
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measuring arterial oxygen saturation from an intraosseous photoplethysmographic signal derived from the sternum.
    Näslund E; Lindberg LG; Lund I; Näslund-Koch L; Larsson A; Frithiof R
    J Clin Monit Comput; 2020 Feb; 34(1):55-62. PubMed ID: 30805761
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of oesophageal reflectance pulse oximetry in major burns patients.
    Pal SK; Kyriacou PA; Kumaran S; Fadheel S; Emamdee R; Langford RM; Jones DP
    Burns; 2005 May; 31(3):337-41. PubMed ID: 15774290
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy enhancement in reflective pulse oximetry by considering wavelength-dependent pathlengths.
    Badiola I; Blazek V; Jagadeesh Kumar V; George B; Leonhardt S; Hoog Antink C
    Physiol Meas; 2022 Sep; 43(9):. PubMed ID: 35959652
    [No Abstract]   [Full Text] [Related]  

  • 18. Pulse oximetry in the pulmonary tissue for the non-invasive measurement of mixed venous oxygen saturation.
    Nitzan M; Nitzan I
    Med Hypotheses; 2013 Aug; 81(2):293-6. PubMed ID: 23679994
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo simulation of the effect of melanin concentration on light-tissue interactions for transmittance pulse oximetry measurement.
    Al-Halawani R; Qassem M; Kyriacou PA
    J Biomed Opt; 2024 Jun; 29(Suppl 3):S33305. PubMed ID: 39139814
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Near-infrared transmittance pulse oximetry with laser diodes.
    Lopez Silva SM; Dotor Castilla ML; Silveira Martin JP
    J Biomed Opt; 2003 Jul; 8(3):525-33. PubMed ID: 12880360
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.