These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 2476780)

  • 21. A comparative study of activity and dual sensor: activity and minute ventilation pacing responses to ascending and descending stairs.
    Alt E; Combs W; Willhaus R; Condie C; Bambl E; Fotuhi P; Pache J; Schömig A
    Pacing Clin Electrophysiol; 1998 Oct; 21(10):1862-8. PubMed ID: 9793080
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinical observations with a dual sensor rate adaptive single chamber pacemaker.
    Provenier F; van Acker R; Backers J; van Wassenhove E; de Meyer V; Jordaens L
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1821-5. PubMed ID: 1279554
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Incidence and timing of activity parameter changes in activity responsive pacing systems.
    Ahern T; Nydegger C; McCormick DJ; Maquilan M; Schuster M; Kutalek SP
    Pacing Clin Electrophysiol; 1992 May; 15(5):762-70. PubMed ID: 1382279
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Clinical experience with an activity sensing DDDR pacemaker using an accelerometer sensor.
    Lau CP; Tai YT; Fong PC; Li JP; Leung SK; Chung FL; Song S
    Pacing Clin Electrophysiol; 1992 Mar; 15(3):334-43. PubMed ID: 1372728
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Dual sensor VVIR mode pacing: is it worth it?
    Sulke N; Tan K; Kamalvand K; Bostock J; Bucknall C
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 1):1560-7. PubMed ID: 8946451
    [TBL] [Abstract][Full Text] [Related]  

  • 26. First derivative of right ventricular pressure, dP/dt, as a sensor for a rate adaptive VVI pacemaker: initial experience.
    Ovsyshcher I; Guetta V; Bondy C; Porath A
    Pacing Clin Electrophysiol; 1992 Feb; 15(2):211-8. PubMed ID: 1372420
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Ventricular rate-adaptive pacing in the elderly.
    Lau CP; Wong CK; Tai YT; Fong PC; Li JP; Chung FL
    Eur Heart J; 1992 Jul; 13(7):908-13. PubMed ID: 1644080
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Chronic frequency-adaptive pacemaker therapy in patients with heart failure].
    Haltern G; Kempa L; Ochs JG; Hanrath P; Sigmund M
    Z Kardiol; 1995 Oct; 84(10):834-43. PubMed ID: 7502571
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Body movement as pacemaker induction value: comparison of 2 activity-triggered pacemakers].
    Stangl K; Wirtzfeld A; Lochschmidt O; Basler B; Mittnacht A
    Z Kardiol; 1988 Apr; 77(4):208-13. PubMed ID: 3388936
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Superior cardiac hemodynamics of atrioventricular synchrony over rate responsive pacing at submaximal exercise: observations in activity sensing DDDR pacemakers.
    Lau CP; Wong CK; Leung WH; Liu WX
    Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 2):1832-7. PubMed ID: 1704550
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The six-minute walk--an adequate exercise test for pacemaker patients?
    Langenfeld H; Schneider B; Grimm W; Beer M; Knoche M; Riegger G; Kochsiek K
    Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 2):1761-5. PubMed ID: 1704537
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Reliability of minute ventilation as a parameter for rate responsive pacing.
    Lau CP; Antoniou A; Ward DE; Camm AJ
    Pacing Clin Electrophysiol; 1989 Feb; 12(2):321-30. PubMed ID: 2468142
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Permanent pacemaker trends in Singapore General Hospital in the eighties.
    Koo CC; Ng MK; Tan AT
    Ann Acad Med Singap; 1990 Jan; 19(1):9-14. PubMed ID: 2327728
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Cardiopulmonary responses to exercise in children with activity sensing rate responsive ventricular pacemakers.
    Cabrera ME; Hanisch DG; Cohen MH; Murtaugh R; Spector ML; Liebman J
    Pacing Clin Electrophysiol; 1993 Jul; 16(7 Pt 1):1386-93. PubMed ID: 7689204
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Cardiopulmonary stress test in variable frequency stimulation: a comparison of Activitrax and Nova-MR pacemakers in VVI/AAI stimulation].
    Alt E; Völker R; Högl B; MacCarter D
    Z Kardiol; 1988 Jul; 77(7):456-63. PubMed ID: 3062957
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Respiration-dependent ventricular pacing compared with fixed ventricular and atrial-ventricular synchronous pacing: aerobic and hemodynamic variables.
    Rossi P; Rognoni G; Occhetta E; Aina F; Prando MD; Plicchi G; Minella M
    J Am Coll Cardiol; 1985 Sep; 6(3):646-52. PubMed ID: 4031276
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Assessment of the work capacity and relationship between rate response and exercise tolerance associated with activity-sensing rate-responsive ventricular pacing.
    Faerestrand S; Breivik K; Ohm OJ
    Pacing Clin Electrophysiol; 1987 Nov; 10(6):1277-90. PubMed ID: 2446275
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Is accurate rate response programming necessary?
    Sulke N; Dritsas A; Chambers J; Sowton E
    Pacing Clin Electrophysiol; 1990 Aug; 13(8):1031-44. PubMed ID: 1697950
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Unexpected loss of bipolar pacing with implanted dual chamber pacemakers.
    Guo GB; Chen MC; Wang CC; Chang KC; Fu M
    Pacing Clin Electrophysiol; 2000 Jan; 23(1):4-7. PubMed ID: 10666747
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Sustained improvement in exercise tolerance following physiological cardiac pacing.
    Sutton R; Perrins EJ; Morley C; Chan SL
    Eur Heart J; 1983 Nov; 4(11):781-5. PubMed ID: 6653589
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.