These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
112 related articles for article (PubMed ID: 24777886)
1. Computational study of the dynamics of a bileaflet mechanical heart valve in the mitral position. Choi YJ; Vedula V; Mittal R Ann Biomed Eng; 2014 Aug; 42(8):1668-80. PubMed ID: 24777886 [TBL] [Abstract][Full Text] [Related]
2. Computational fluid dynamics study of a protruded-hinge bileaflet mechanical heart valve. Wang J; Yao H; Lim CJ; Zhao Y; Yeo TJ; Hwang NH J Heart Valve Dis; 2001 Mar; 10(2):254-262; discussion 263. PubMed ID: 11297213 [TBL] [Abstract][Full Text] [Related]
3. Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition. Shi Y; Zhao Y; Yeo TJ; Hwang NH J Heart Valve Dis; 2003 Mar; 12(2):245-55. PubMed ID: 12701798 [TBL] [Abstract][Full Text] [Related]
4. The effects of dynamic saddle annulus and leaflet length on transmitral flow pattern and leaflet stress of a bileaflet bioprosthetic mitral valve. Kheradvar A; Falahatpisheh A J Heart Valve Dis; 2012 Mar; 21(2):225-33. PubMed ID: 22645859 [TBL] [Abstract][Full Text] [Related]
5. Direct imaging of bileaflet mechanical valve behavior in the tricuspid position. Ikeda K; Okazaki Y; Furukawa K; Ohtsubo S; Yunoki J; Natsuaki M; Itoh T Eur J Cardiothorac Surg; 2006 Jun; 29(6):1014-9. PubMed ID: 16675254 [TBL] [Abstract][Full Text] [Related]
6. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model. Dumont K; Vierendeels J; Kaminsky R; van Nooten G; Verdonck P; Bluestein D J Biomech Eng; 2007 Aug; 129(4):558-65. PubMed ID: 17655477 [TBL] [Abstract][Full Text] [Related]
8. An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve. Shu MC; Gross JM; O'Rourke KK; Yoganathan AP J Heart Valve Dis; 2003 Jul; 12(4):503-12. PubMed ID: 12918854 [TBL] [Abstract][Full Text] [Related]
9. Numerical analysis on the hemodynamics and leaflet dynamics in a bileaflet mechanical heart valve using a fluid-structure interaction method. Choi CR; Kim CN ASAIO J; 2009; 55(5):428-37. PubMed ID: 19730001 [TBL] [Abstract][Full Text] [Related]
10. 3-D simulation of the St. Jude Medical bileaflet valve opening process: fluid-structure interaction study and experimental validation. Redaelli A; Bothorel H; Votta E; Soncini M; Morbiducci U; Del Gaudio C; Balducci A; Grigioni M J Heart Valve Dis; 2004 Sep; 13(5):804-13. PubMed ID: 15473484 [TBL] [Abstract][Full Text] [Related]
11. Pressure and flow fields in the hinge region of bileaflet mechanical heart valves. Gao ZB; Hosein N; Dai FF; Hwang NH J Heart Valve Dis; 1999 Mar; 8(2):197-205. PubMed ID: 10224581 [TBL] [Abstract][Full Text] [Related]
12. The hemodynamic effects of mechanical prosthetic valve type and orientation on fluid mechanical energy loss and pressure drop in in vitro models of ventricular hypertrophy. Travis BR; Heinrich RS; Ensley AE; Gibson DE; Hashim S; Yoganathan AP J Heart Valve Dis; 1998 May; 7(3):345-54. PubMed ID: 9651851 [TBL] [Abstract][Full Text] [Related]
18. Numerical simulation of the dynamics of a bileaflet prosthetic heart valve using a fluid-structure interaction approach. Nobili M; Morbiducci U; Ponzini R; Del Gaudio C; Balducci A; Grigioni M; Maria Montevecchi F; Redaelli A J Biomech; 2008 Aug; 41(11):2539-50. PubMed ID: 18579146 [TBL] [Abstract][Full Text] [Related]
19. Numerical Modeling of Intraventricular Flow during Diastole after Implantation of BMHV. Su B; Kabinejadian F; Phang HQ; Kumar GP; Cui F; Kim S; Tan RS; Hon JK; Allen JC; Leo HL; Zhong L PLoS One; 2015; 10(5):e0126315. PubMed ID: 25961285 [TBL] [Abstract][Full Text] [Related]
20. New insights into the assessment of the prosthetic valve performance in the presence of subaortic stenosis through a fluid-structure interaction model. Guivier C; Deplano V; Pibarot P J Biomech; 2007; 40(10):2283-90. PubMed ID: 17161842 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]