These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

84 related articles for article (PubMed ID: 24786372)

  • 1. Range verification for eye proton therapy based on proton-induced x-ray emissions from implanted metal markers.
    La Rosa V; Kacperek A; Royle G; Gibson A
    Phys Med Biol; 2014 Jun; 59(11):2623-38. PubMed ID: 24786372
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric impact of tantalum markers used in the treatment of uveal melanoma with proton beam therapy.
    Newhauser WD; Koch NC; Fontenot JD; Rosenthal SJ; S Gombos D; Fitzek MM; Mohan R
    Phys Med Biol; 2007 Jul; 52(13):3979-90. PubMed ID: 17664589
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preclinical investigation for developing injectable fiducial markers using a mixture of BaSO4 and biodegradable polymer for proton therapy.
    Ahn SH; Gil MS; Lee DS; Han Y; Park HC; Sohn JW; Kim HY; Shin EH; Yu JI; Noh JM; Cho JS; Ahn SH; Choi DH
    Med Phys; 2015 May; 42(5):2626-37. PubMed ID: 25979054
    [TBL] [Abstract][Full Text] [Related]  

  • 4. SU-E-J-66: Evaluation of Proton Induced X-Ray Fluorescence from Gold Fiducial Markers for In-Vivo Determination of Proton Range and Energy.
    Tonner B; Li Z; Tishler D
    Med Phys; 2012 Jun; 39(6Part7):3667. PubMed ID: 28519792
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monte Carlo simulations of the dosimetric impact of radiopaque fiducial markers for proton radiotherapy of the prostate.
    Newhauser W; Fontenot J; Koch N; Dong L; Lee A; Zheng Y; Waters L; Mohan R
    Phys Med Biol; 2007 Jun; 52(11):2937-52. PubMed ID: 17505081
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Technical Note: Feasibility study of titanium markers in choroidal melanoma localization for proton beam radiation therapy.
    Daftari IK; Quivey JM; Chang JS; Mishra KK
    Med Phys; 2018 Mar; 45(3):1036-1039. PubMed ID: 29377168
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prompt gamma imaging with a slit camera for real-time range control in proton therapy.
    Smeets J; Roellinghoff F; Prieels D; Stichelbaut F; Benilov A; Busca P; Fiorini C; Peloso R; Basilavecchia M; Frizzi T; Dehaes JC; Dubus A
    Phys Med Biol; 2012 Jun; 57(11):3371-405. PubMed ID: 22572603
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Depth dose perturbation by a hydrogel fiducial marker in a proton beam.
    Zhang M; Reyhan M; Kim LH
    J Appl Clin Med Phys; 2015 Jan; 16(1):5090. PubMed ID: 25679167
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biological effect of dose distortion by fiducial markers in spot-scanning proton therapy with a limited number of fields: a simulation study.
    Matsuura T; Maeda K; Sutherland K; Takayanagi T; Shimizu S; Takao S; Miyamoto N; Nihongi H; Toramatsu C; Nagamine Y; Fujimoto R; Suzuki R; Ishikawa M; Umegaki K; Shirato H
    Med Phys; 2012 Sep; 39(9):5584-91. PubMed ID: 22957624
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of X-ray and proton beam low energy secondary electron track structures using the low energy models of Geant4.
    McNamara AL; Guatelli S; Prokopovich DA; Reinhard MI; Rosenfeld AB
    Int J Radiat Biol; 2012 Jan; 88(1-2):164-70. PubMed ID: 22040102
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Preliminary analysis for integration of spot-scanning proton beam therapy and real-time imaging and gating.
    Shimizu S; Matsuura T; Umezawa M; Hiramoto K; Miyamoto N; Umegaki K; Shirato H
    Phys Med; 2014 Jul; 30(5):555-8. PubMed ID: 24786663
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric impact of fiducial markers in patients undergoing photon beam radiation therapy.
    Vassiliev ON; Kudchadker RJ; Kuban DA; Frank SJ; Choi S; Nguyen Q; Lee AK
    Phys Med; 2012 Jul; 28(3):240-4. PubMed ID: 21875820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterization of the HollandPTC proton therapy beamline dedicated to uveal melanoma treatment and an interinstitutional comparison.
    Fleury E; Trnková P; Spruijt K; Herault J; Lebbink F; Heufelder J; Hrbacek J; Horwacik T; Kajdrowicz T; Denker A; Gerard A; Hofverberg P; Mamalui M; Slopsema R; Pignol JP; Hoogeman M
    Med Phys; 2021 Aug; 48(8):4506-4522. PubMed ID: 34091930
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intraoperative localization of tantalum markers for proton beam radiation of choroidal melanoma by an opto-electronic navigation system: a novel technique.
    Amstutz CA; Bechrakis NE; Foerster MH; Heufelder J; Kowal JH
    Int J Radiat Oncol Biol Phys; 2012 Mar; 82(4):1361-6. PubMed ID: 21665382
    [TBL] [Abstract][Full Text] [Related]  

  • 15. GEANT4 simulation of a range verification method using delayed γ spectroscopy of a
    Kasanda E; Burbadge C; Bildstein V; Turko J; Spyrou A; Höhr C; Mücher D
    Phys Med Biol; 2020 Dec; 65(24):245047. PubMed ID: 33331299
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On-line range verification for proton beam therapy using spherical ionoacoustic waves with resonant frequency.
    Takayanagi T; Uesaka T; Nakamura Y; Unlu MB; Kuriyama Y; Uesugi T; Ishi Y; Kudo N; Kobayashi M; Umegaki K; Tomioka S; Matsuura T
    Sci Rep; 2020 Nov; 10(1):20385. PubMed ID: 33230208
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of prompt gamma-ray emission with respect to the Bragg peak for proton beam range verification: A Monte Carlo study.
    Zarifi M; Guatelli S; Bolst D; Hutton B; Rosenfeld A; Qi Y
    Phys Med; 2017 Jan; 33():197-206. PubMed ID: 28027864
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Therapeutic application of metallic nanoparticles combined with particle-induced x-ray emission effect.
    Kim JK; Seo SJ; Kim KH; Kim TJ; Chung MH; Kim KR; Yang TK
    Nanotechnology; 2010 Oct; 21(42):425102. PubMed ID: 20858930
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sensitivity study of proton radiography and comparison with kV and MV x-ray imaging using GEANT4 Monte Carlo simulations.
    Depauw N; Seco J
    Phys Med Biol; 2011 Apr; 56(8):2407-21. PubMed ID: 21427482
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Off-axis dose equivalent due to secondary neutrons from uniform scanning proton beams during proton radiotherapy.
    Islam MR; Collums TL; Zheng Y; Monson J; Benton ER
    Phys Med Biol; 2013 Nov; 58(22):8235-51. PubMed ID: 24201018
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.