  • 41. Repetitive reentrant and non-reentrant ventriculoatrial synchrony in dual chamber pacing.
    Barold SS
    Clin Cardiol; 1991 Sep; 14(9):754-63. PubMed ID: 1720713
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Efficacy and safety of bipolar sensing with high atrial sensitivity in dual chamber pacemakers.
    Wiegand UK; Bode F; Peters W; Haase H; Bonnemeier H; Katus HA; Potratz J
    Pacing Clin Electrophysiol; 2000 Apr; 23(4 Pt 1):427-33. PubMed ID: 10793429
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Far-field QRS complex sensing via the atrial pacemaker lead. I. Mechanism, consequences, differential diagnosis and countermeasures in AAI and VDD/DDD pacing.
    Brandt J; Fåhraeus T; Schüller H
    Pacing Clin Electrophysiol; 1988 Oct; 11(10):1432-8. PubMed ID: 2462220
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Lack of sensing by demand pacemakers due to intraventricular conduction defects.
    Vera Z; Mason DT; Awan NA; Hiliard G; Massumi RA
    Circulation; 1975 May; 51(5):815-22. PubMed ID: 47273
    [TBL] [Abstract][Full Text] [Related]  

  • 45. [Arrhythmia in patients with a DDD bicameral pacemaker].
    Occhetta E; Magnani A; Prando MD; Perucca A; Rossi L; Rognoni G; Rossi P
    G Ital Cardiol; 1986 Nov; 16(11):909-21. PubMed ID: 2435600
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Unusual presentation of DDD pacemaker system malfunction.
    Stark S; Farshidi A; Hager WD; Donaldson MC
    Pacing Clin Electrophysiol; 1985 Mar; 8(2):255-60. PubMed ID: 2580287
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Problems of sensing tachyarrhythmias by an antitachycardia pacemaker (Symbios 7008).
    Nürnberg M; Biber B; Frohner K; Rabitsch C; Steinbach K
    Pacing Clin Electrophysiol; 1989 Apr; 12(4 Pt 1):537-41. PubMed ID: 2470034
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Pseudohysteresis in a universal AV sequential pacemaker.
    Quintal RE; Dhurandhar RW; Jain RK
    Pacing Clin Electrophysiol; 1987 Mar; 10(2):378-81. PubMed ID: 2437542
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Atrial lead dislodgement with a DDD pacemaker.
    Greenspon AJ; Cox J; Greenberg RM
    Pacing Clin Electrophysiol; 1986 May; 9(3):436-40. PubMed ID: 2423986
    [TBL] [Abstract][Full Text] [Related]  

  • 50. The "automatic mode switch" function in successive generations of minute ventilation sensing dual chamber rate responsive pacemakers.
    Provenier F; Jordaens L; Verstraeten T; Clement DL
    Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):1913-9. PubMed ID: 7845791
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Orthodromic pacemaker circus movement tachycardia.
    den Heijer P; Crijns HJ; Van Binsbergen EJ; Ebels T; De Jongste MJ; Lie KI
    Pacing Clin Electrophysiol; 1987 Jul; 10(4 Pt 1):955-7. PubMed ID: 2441382
    [TBL] [Abstract][Full Text] [Related]  

  • 52. VVI pacemaker ventricular undersensing.
    Johnson CD
    Bol Asoc Med P R; 1986 Jan; 78(1):21-5. PubMed ID: 3456750
    [No Abstract]   [Full Text] [Related]  

  • 53. Cross-ventricular pacemaker-mediated tachycardia by myopotential induction during biventricular pacing.
    Guenoun M; Hero M; Roux O; Mainardis M
    Pacing Clin Electrophysiol; 2005 Jun; 28(6):585-7. PubMed ID: 15955194
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Implantation strategy of the atrial dipole impacts atrial sensing performance of single lead VDD pacemakers.
    Wiegand UK; Nowak B; Reisp U; Peiffer T; Bode F; Potratz J;
    Pacing Clin Electrophysiol; 2002 Mar; 25(3):316-23. PubMed ID: 11990661
    [TBL] [Abstract][Full Text] [Related]  

  • 55. DDI pacing: indications, expectations, and follow-up.
    Irwin M; Harris L; Cameron D; Louis C; Radvanszky E; Goldman B
    Pacing Clin Electrophysiol; 1994 Mar; 17(3 Pt 1):274-9. PubMed ID: 7513851
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Atrial synchronous ventricular inhibited (VDD) pacemaker-mediated arrhythmia due to atrial undersensing and atrial lead oversensing of far-field ventricular afterpotentials or paced beats: crosstalk.
    Johnson CD
    Pacing Clin Electrophysiol; 1986 Sep; 9(5):710-9. PubMed ID: 2429278
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Ventricular output failure in a DDD permanent pacemaker associated with increased atrial output.
    Santucci PA; Mitra RL
    Pacing Clin Electrophysiol; 1997 Nov; 20(11):2860-3. PubMed ID: 9392819
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Characterization of pacemaker arrhythmias due to normally functioning AV demand (DVI) pulse generators.
    Barold SS; Falkoff MD; Ong LS; Heinle RA
    Pacing Clin Electrophysiol; 1980 Nov; 3(6):712-23. PubMed ID: 6161354
    [TBL] [Abstract][Full Text] [Related]  

  • 59. 2:1 atrial capture as the cause of pacemaker alternans.
    Jordaens LJ; van Wassenhove E; Clement DL
    Cardiology; 1988; 75(4):283-6. PubMed ID: 3167918
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Undersensing of the tiny QRS complexes that emerged after the isolation of the right ventricle in a patient with ventricular tachycardia.
    Güldal M; Karaoğuz R; Pacifico A; Lawrie GM; Akyol T
    Pacing Clin Electrophysiol; 1996 May; 19(5):868-71. PubMed ID: 8734758
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]