These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
106 related articles for article (PubMed ID: 24789975)
41. Single-chamber ventricular pacing increases markers of left ventricular dysfunction compared with dual-chamber pacing. Naegeli B; Kurz DJ; Koller D; Straumann E; Furrer M; Maurer D; Minder E; Bertel O Europace; 2007 Mar; 9(3):194-9. PubMed ID: 17272326 [TBL] [Abstract][Full Text] [Related]
42. Long-term safety and efficacy of right ventricular outflow tract pacing in patients with permanent pacemakers. Erdoğan O; Aktöz M; Altun A Anadolu Kardiyol Derg; 2008 Oct; 8(5):350-3. PubMed ID: 18849226 [TBL] [Abstract][Full Text] [Related]
43. Atrial evoked response integral for automatic capture verification in atrial pacing. Boriani G; Biffi M; Cameron D; Datteri S; Snell J; Holmström N; Park E; Bornzin GA Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):248-52. PubMed ID: 12687822 [TBL] [Abstract][Full Text] [Related]
44. Pacemaker-mediated tachycardia initiated by an atrioventricular search algorithm to minimize right ventricular pacing. Barold SS; Stroobandt RX J Electrocardiol; 2012; 45(3):336-9. PubMed ID: 22280797 [TBL] [Abstract][Full Text] [Related]
45. Impact of right ventricular pacing sites on exercise capacity during ventricular rate regularization in patients with permanent atrial fibrillation. Tse HF; Siu CW; Lau CP Pacing Clin Electrophysiol; 2009 Dec; 32(12):1536-42. PubMed ID: 19825009 [TBL] [Abstract][Full Text] [Related]
46. [Autocapture(TM) and Capture Management(TM) Current concepts in pacing threshold and output management]. Anelli-Monti M; Mächler H; Oberwalder P; Dacar D; Knez I; Salaymeh L; Streinu C; Rigler B Herzschrittmacherther Elektrophysiol; 2001 Dec; 12(4):186-94. PubMed ID: 27432388 [TBL] [Abstract][Full Text] [Related]
49. The efficacy of ventricular pacing with device automaticity in paediatric patients. Tomaske M; Harpes P; Woy N; Bauersfeld U Europace; 2008 Jul; 10(7):838-43. PubMed ID: 18319269 [TBL] [Abstract][Full Text] [Related]
50. [Comparison of VVI and DDD cardiac stimulation during exercise test evaluated by respiratory gas exchange measurement. Study of patients with normal systolic function and complete atrioventricular block unchanged during exercise test]. Chabernaud JM; Guéret P; Blanc P; Bavoux O; Bensaid J Arch Mal Coeur Vaiss; 1993 Jan; 86(1):69-74. PubMed ID: 8338403 [TBL] [Abstract][Full Text] [Related]
51. Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. Canadian Trial of Physiologic Pacing Investigators. Connolly SJ; Kerr CR; Gent M; Roberts RS; Yusuf S; Gillis AM; Sami MH; Talajic M; Tang AS; Klein GJ; Lau C; Newman DM N Engl J Med; 2000 May; 342(19):1385-91. PubMed ID: 10805823 [TBL] [Abstract][Full Text] [Related]
52. Optimizing pacemaker longevity with pacing mode and settings programming: results from a pacemaker multicenter registry. Benkemoun H; Sacrez J; Lagrange P; Amiel A; Prakash A; Himmrich E; Aimè E; Mairesse GH; Guénon C; Sbragia P Pacing Clin Electrophysiol; 2012 Apr; 35(4):403-8. PubMed ID: 22309354 [TBL] [Abstract][Full Text] [Related]
53. Ventricular tachycardia induced by a backup pacing stimulus in a patient with a dual chamber pacemaker with AutoCapture. Greenspon AJ; Frisch DR; Ho RT; Pavri BB Pacing Clin Electrophysiol; 2021 Jun; 44(6):1130-1132. PubMed ID: 33590525 [TBL] [Abstract][Full Text] [Related]
54. [Atrial fibrillation before and after pacemaker implantation (WI and DDD) in patients with complete atrioventricular block]. Matusik P; Woznica N; Lelakowsk J Pol Merkur Lekarski; 2010 May; 28(167):345-9. PubMed ID: 20568394 [TBL] [Abstract][Full Text] [Related]
55. The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial: rationale, design, results, clinical implications and lessons for future trials. Wilkoff BL; Card Electrophysiol Rev; 2003 Dec; 7(4):468-72. PubMed ID: 15071277 [TBL] [Abstract][Full Text] [Related]
56. Ventricular fibrillation induced by double premature ventricular pacing stimuli in a dual-chamber pacemaker with AutoCapture. Sweeney MO; Porkolab FL Heart Rhythm; 2009 Mar; 6(3):429-32. PubMed ID: 19251223 [No Abstract] [Full Text] [Related]
57. Italian experience with AutoCapture in conjunction with a membrane lead. Pacesetter Automatic Control of Energy and Membrane Automatic Threshold Evaluation (Pacemate) Study Group. Sermasi S; Marconi M; Libero L; Moracchini PV; Rusconi L; Mininno A; Sigliano R Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1799-804. PubMed ID: 8945044 [TBL] [Abstract][Full Text] [Related]