These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 24793398)

  • 1. Building, testing and validating a set of home-made von Frey filaments: a precise, accurate and cost effective alternative for nociception assessment.
    de Sousa MV; Ferraresi C; de Magalhães AC; Yoshimura EM; Hamblin MR
    J Neurosci Methods; 2014 Jul; 232():1-5. PubMed ID: 24793398
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical Nociception in Mice and Rats: Measurement with Automated von Frey Equipment.
    Campana G; Rimondini R
    Methods Mol Biol; 2021; 2201():195-198. PubMed ID: 32975800
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Paw withdrawal threshold in the von Frey hair test is influenced by the surface on which the rat stands.
    Pitcher GM; Ritchie J; Henry JL
    J Neurosci Methods; 1999 Mar; 87(2):185-93. PubMed ID: 11230815
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of manual and automated filaments for evaluation of neuropathic pain behavior in rats.
    Nirogi R; Goura V; Shanmuganathan D; Jayarajan P; Abraham R
    J Pharmacol Toxicol Methods; 2012 Jul; 66(1):8-13. PubMed ID: 22575456
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative sensory testing with Electronic von Frey Anesthesiometer and von Frey filaments in nonpainful cats: a pilot study.
    Machin H; Kato E; Adami C
    Vet Anaesth Analg; 2019 Mar; 46(2):251-254. PubMed ID: 30709737
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanical nociception measurement in mice and rats with automated Von Frey equipment.
    Campana G; Rimondini R
    Methods Mol Biol; 2015; 1230():229-31. PubMed ID: 25293329
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A simplified up-down method (SUDO) for measuring mechanical nociception in rodents using von Frey filaments.
    Bonin RP; Bories C; De Koninck Y
    Mol Pain; 2014 Apr; 10():26. PubMed ID: 24739328
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Normative Preclinical Algesiometry Data on the von Frey and Radiant Heat Paw-Withdrawal Tests: An Analysis of Data from More Than 8,000 Mice Over 20 Years.
    Zumbusch AS; McEachern ELF; Morgan OB; Nickner E; Mogil JS
    J Pain; 2024 Jul; 25(7):104468. PubMed ID: 38219851
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A modified Hargreaves' method for assessing threshold temperatures for heat nociception.
    Banik RK; Kabadi RA
    J Neurosci Methods; 2013 Sep; 219(1):41-51. PubMed ID: 23796910
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Differential activities of intrathecal MK-801 or morphine to alter responses to thermal and mechanical stimuli in normal or nerve-injured rats.
    Wegert S; Ossipov MH; Nichols ML; Bian D; Vanderah TW; Malan TP; Porreca F
    Pain; 1997 May; 71(1):57-64. PubMed ID: 9200174
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measuring changes in tactile sensitivity in the hind paw of mice using an electronic von Frey apparatus.
    Martinov T; Mack M; Sykes A; Chatterjea D
    J Vis Exp; 2013 Dec; (82):e51212. PubMed ID: 24378519
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An electronic pressure-meter nociception paw test for mice.
    Cunha TM; Verri WA; Vivancos GG; Moreira IF; Reis S; Parada CA; Cunha FQ; Ferreira SH
    Braz J Med Biol Res; 2004 Mar; 37(3):401-7. PubMed ID: 15060710
    [TBL] [Abstract][Full Text] [Related]  

  • 13. 'CatWalk' automated quantitative gait analysis as a novel method to assess mechanical allodynia in the rat; a comparison with von Frey testing.
    Vrinten DH; Hamers FF
    Pain; 2003 Mar; 102(1-2):203-9. PubMed ID: 12620612
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimating efficacy and drug ED50's using von Frey thresholds: impact of weber's law and log transformation.
    Mills C; Leblond D; Joshi S; Zhu C; Hsieh G; Jacobson P; Meyer M; Decker M
    J Pain; 2012 Jun; 13(6):519-23. PubMed ID: 22543045
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Practical mechanical threshold estimation in rodents using von Frey hairs/Semmes-Weinstein monofilaments: Towards a rational method.
    Bradman MJ; Ferrini F; Salio C; Merighi A
    J Neurosci Methods; 2015 Nov; 255():92-103. PubMed ID: 26296284
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of von Frey filaments to assess nociceptive sensitization in the hornworm, Manduca sexta.
    McMackin MZ; Lewin MR; Tabuena DR; Arreola FE; Moffatt C; Fuse M
    J Neurosci Methods; 2016 Jan; 257():139-46. PubMed ID: 26432932
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of movement-evoked pain in osteoarthritis by the knee-bend and CatWalk tests: a clinically relevant study.
    Ferreira-Gomes J; Adães S; Castro-Lopes JM
    J Pain; 2008 Oct; 9(10):945-54. PubMed ID: 18650131
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of CatWalk analysis and von Frey testing for pain assessment in a rat model of nerve crush plus inflammation.
    Sakuma T; Kamoda H; Miyagi M; Ishikawa T; Arai G; Eguchi Y; Suzuki M; Oikawa Y; Sakuma Y; Kubota G; Inage K; Saino T; Orita S; Yamauchi K; Inoue G; Takahashi K; Ohtori S
    Spine (Phila Pa 1976); 2013 Jul; 38(15):E919-24. PubMed ID: 23615382
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Application of calibrated forceps for assessing mechanical nociception with high time resolution in mice.
    Kashiwadani H; Kanmura Y; Kuwaki T
    PLoS One; 2017; 12(2):e0172461. PubMed ID: 28212389
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reproducibility of Electronic Von Frey and Von Frey monofilaments testing.
    Tena B; Escobar B; Arguis MJ; Cantero C; Rios J; Gomar C
    Clin J Pain; 2012 May; 28(4):318-23. PubMed ID: 22001670
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.