349 related articles for article (PubMed ID: 24801401)
1. In vivo implantation of porous titanium alloy implants coated with magnesium-doped octacalcium phosphate and hydroxyapatite thin films using pulsed laser depostion.
Mróz W; Budner B; Syroka R; Niedzielski K; Golański G; Slósarczyk A; Schwarze D; Douglas TE
J Biomed Mater Res B Appl Biomater; 2015 Jan; 103(1):151-8. PubMed ID: 24801401
[TBL] [Abstract][Full Text] [Related]
2. Osteoconductivity and osteoinductivity of porous hydroxyapatite coatings deposited by liquid precursor plasma spraying: in vivo biological response study.
Huang Y; He J; Gan L; Liu X; Wu Y; Wu F; Gu ZW
Biomed Mater; 2014 Nov; 9(6):065007. PubMed ID: 25384201
[TBL] [Abstract][Full Text] [Related]
3. The effect of strontium and silicon substituted hydroxyapatite electrochemical coatings on bone ingrowth and osseointegration of selective laser sintered porous metal implants.
Mumith A; Cheong VS; Fromme P; Coathup MJ; Blunn GW
PLoS One; 2020; 15(1):e0227232. PubMed ID: 31923253
[TBL] [Abstract][Full Text] [Related]
4. Bone response adjacent to calcium phosphate electrostatic spray deposition coated implants: an experimental study in goats.
Manders PJ; Wolke JG; Jansen JA
Clin Oral Implants Res; 2006 Oct; 17(5):548-53. PubMed ID: 16958695
[TBL] [Abstract][Full Text] [Related]
5. The effect of sol-gel-formed calcium phosphate coatings on bone ingrowth and osteoconductivity of porous-surfaced Ti alloy implants.
Nguyen HQ; Deporter DA; Pilliar RM; Valiquette N; Yakubovich R
Biomaterials; 2004 Feb; 25(5):865-76. PubMed ID: 14609675
[TBL] [Abstract][Full Text] [Related]
6. Characteristics of hydroxyapatite coated titanium porous coatings on Ti-6Al-4V substrates by plasma sprayed method.
Yang CY; Chen CR; Chang E; Lee TM
J Biomed Mater Res B Appl Biomater; 2007 Aug; 82(2):450-9. PubMed ID: 17245748
[TBL] [Abstract][Full Text] [Related]
7. Assessment of osteoinduction using a porous hydroxyapatite coating prepared by micro-arc oxidation on a new titanium alloy.
Jing W; Zhang M; Jin L; Zhao J; Gao Q; Ren M; Fan Q
Int J Surg; 2015 Dec; 24(Pt A):51-6. PubMed ID: 26306772
[TBL] [Abstract][Full Text] [Related]
8. In vivo biocompatibility and mechanical study of novel bone-bioactive materials for prosthetic implantation.
Zhang XS; Revell PA; Evans SL; Tuke MA; Gregson PJ
J Biomed Mater Res; 1999 Aug; 46(2):279-86. PubMed ID: 10380007
[TBL] [Abstract][Full Text] [Related]
9. In vivo comparison of bone formation on titanium implant surfaces coated with biomimetically deposited calcium phosphate or electrochemically deposited hydroxyapatite.
Yang GL; He FM; Song E; Hu JA; Wang XX; Zhao SF
Int J Oral Maxillofac Implants; 2010; 25(4):669-80. PubMed ID: 20657861
[TBL] [Abstract][Full Text] [Related]
10. BS-SEM evaluation of the tissular interactions between cortical bone and calcium-phosphate covered titanium implants.
Manzanares MC; Franch J; Carvalho P; Belmonte AM; Tusell J; Franch B; Fernandez JM; Clèries L; Morenza JL
Bull Group Int Rech Sci Stomatol Odontol; 2001; 43(3):100-8. PubMed ID: 11938587
[TBL] [Abstract][Full Text] [Related]
11. In vivo degradation and bone response of a composite coating on Mg-Zn-Ca alloy prepared by microarc oxidation and electrochemical deposition.
Chen S; Guan S; Li W; Wang H; Chen J; Wang Y; Wang H
J Biomed Mater Res B Appl Biomater; 2012 Feb; 100(2):533-43. PubMed ID: 22120974
[TBL] [Abstract][Full Text] [Related]
12. A silver ion-doped calcium phosphate-based ceramic nanopowder-coated prosthesis increased infection resistance.
Kose N; Otuzbir A; Pekşen C; Kiremitçi A; Doğan A
Clin Orthop Relat Res; 2013 Aug; 471(8):2532-9. PubMed ID: 23463287
[TBL] [Abstract][Full Text] [Related]
13. Effect of hydroxyapatite/tricalcium-phosphate coating on osseointegration of plasma-sprayed titanium alloy implants.
Stewart M; Welter JF; Goldberg VM
J Biomed Mater Res A; 2004 Apr; 69(1):1-10. PubMed ID: 14999745
[TBL] [Abstract][Full Text] [Related]
14. Combined Treatment Effects Using Bioactive-Coated Implants and Ceramic Granulate in a Rabbit Femoral Condyle Model.
Preethanath RS; Rajesh P; Varma H; Anil S; Jansen JA; van den Beucken JJ
Clin Implant Dent Relat Res; 2016 Aug; 18(4):666-77. PubMed ID: 26115085
[TBL] [Abstract][Full Text] [Related]
15. Influence of octacalcium phosphate coating on osteoinductive properties of biomaterials.
Habibovic P; van der Valk CM; van Blitterswijk CA; De Groot K; Meijer G
J Mater Sci Mater Med; 2004 Apr; 15(4):373-80. PubMed ID: 15332602
[TBL] [Abstract][Full Text] [Related]
16. Intermittent administration of human parathyroid hormone (1-34) increases fixation of strontium-doped hydroxyapatite coating titanium implants via electrochemical deposition in ovariectomized rat femur.
Tao ZS; Zhou WS; Qiang Z; Tu KK; Huang ZL; Xu HM; Sun T; Lv YX; Cui W; Yang L
J Biomater Appl; 2016 Feb; 30(7):952-60. PubMed ID: 26482573
[TBL] [Abstract][Full Text] [Related]
17. Histomorphometry of hydroxyapatite coated and uncoated porous titanium bone implants.
Moroni A; Caja VL; Egger EL; Trinchese L; Chao EY
Biomaterials; 1994 Sep; 15(11):926-30. PubMed ID: 7833442
[TBL] [Abstract][Full Text] [Related]
18. In vivo investigation of calcium phosphate coatings on Ti6-Al-4V alloy substrates using lactic acid - sodium lactate buffered synthetic body fluid.
Havitçioğlu H; Ceçen B; Pasinli A; Yüksel M; Aydin I; Yildiz H
Acta Orthop Traumatol Turc; 2013; 47(6):417-22. PubMed ID: 24509222
[TBL] [Abstract][Full Text] [Related]
19. Early inflammatory response in soft tissues induced by thin calcium phosphates.
Rydén L; Molnar D; Esposito M; Johansson A; Suska F; Palmquist A; Thomsen P
J Biomed Mater Res A; 2013 Sep; 101(9):2712-7. PubMed ID: 23463679
[TBL] [Abstract][Full Text] [Related]
20. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: An in vivo experiment.
Taniguchi N; Fujibayashi S; Takemoto M; Sasaki K; Otsuki B; Nakamura T; Matsushita T; Kokubo T; Matsuda S
Mater Sci Eng C Mater Biol Appl; 2016 Feb; 59():690-701. PubMed ID: 26652423
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]