These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

299 related articles for article (PubMed ID: 24802315)

  • 1. Open reduction and internal fixation versus external fixation and/or kirschner wires for distal radius fractures. A systematic review.
    Kasapinova K; Kamiloski V
    Pril (Makedon Akad Nauk Umet Odd Med Nauki); 2014; 35(1):225-36. PubMed ID: 24802315
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation.
    Wright TW; Horodyski M; Smith DW
    J Hand Surg Am; 2005 Mar; 30(2):289-99. PubMed ID: 15781351
    [TBL] [Abstract][Full Text] [Related]  

  • 3. External fixation versus open reduction with plate fixation for distal radius fractures: a meta-analysis of randomised controlled trials.
    Esposito J; Schemitsch EH; Saccone M; Sternheim A; Kuzyk PR
    Injury; 2013 Apr; 44(4):409-16. PubMed ID: 23298757
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Open reduction internal fixation versus percutaneous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial.
    Grewal R; MacDermid JC; King GJ; Faber KJ
    J Hand Surg Am; 2011 Dec; 36(12):1899-906. PubMed ID: 22051229
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Are Volar Locking Plates Superior to Percutaneous K-wires for Distal Radius Fractures? A Meta-analysis.
    Chaudhry H; Kleinlugtenbelt YV; Mundi R; Ristevski B; Goslings JC; Bhandari M
    Clin Orthop Relat Res; 2015 Sep; 473(9):3017-27. PubMed ID: 25981715
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Volar Locking Plate or External Fixation With Optional Addition of K-Wires for Dorsally Displaced Distal Radius Fractures: A Randomized Controlled Study.
    Mellstrand Navarro C; Ahrengart L; Törnqvist H; Ponzer S
    J Orthop Trauma; 2016 Apr; 30(4):217-24. PubMed ID: 26709818
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Meta-analysis for dorsally displaced distal radius fracture fixation: volar locking plate versus percutaneous Kirschner wires.
    Zong SL; Kan SL; Su LX; Wang B
    J Orthop Surg Res; 2015 Jul; 10():108. PubMed ID: 26169601
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Association of Open Reduction and Internal Fixation With Volar Locking Plate for Distal Radius Fractures With Patient-Reported Outcomes in Older Adults: A Network Meta-analysis.
    Jayaram M; Wood SM; Kane RL; Yang LY; Chung KC
    JAMA Netw Open; 2023 Jun; 6(6):e2318715. PubMed ID: 37326988
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius.
    Richard MJ; Wartinbee DA; Riboh J; Miller M; Leversedge FJ; Ruch DS
    J Hand Surg Am; 2011 Oct; 36(10):1614-20. PubMed ID: 21849236
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A randomized prospective study on the treatment of intra-articular distal radius fractures: open reduction and internal fixation with dorsal plating versus mini open reduction, percutaneous fixation, and external fixation.
    Grewal R; Perey B; Wilmink M; Stothers K
    J Hand Surg Am; 2005 Jul; 30(4):764-72. PubMed ID: 16039370
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Volar plate versus k-wire fixation of distal radius fractures.
    Brennan SA; Kiernan C; Beecher S; O'Reilly RT; Devitt BM; Kearns SR; O'Sullivan ME
    Injury; 2016 Feb; 47(2):372-6. PubMed ID: 26592093
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].
    Yang Z; Yuan ZZ; Ma JX; Ma XL
    Zhonghua Yi Xue Za Zhi; 2017 Nov; 97(41):3269-3272. PubMed ID: 29141368
    [No Abstract]   [Full Text] [Related]  

  • 13. Is it really necessary to restore radial anatomic parameters after distal radius fractures?
    Dario P; Matteo G; Carolina C; Marco G; Cristina D; Daniele F; Andrea F
    Injury; 2014 Dec; 45 Suppl 6():S21-6. PubMed ID: 25457314
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures.
    Mishra RK; Sharma BP; Kumar A; Sherawat R
    Chin J Traumatol; 2021 Sep; 24(5):301-305. PubMed ID: 33994084
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Meta-analysis of external fixator and open reduction and internal fixation for the treatment of distal radius fracture].
    Yuan SP; Zhang XP; Sun Y; Wei X
    Zhongguo Gu Shang; 2021 May; 34(5):429-37. PubMed ID: 34032044
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Volar locking plating versus percutaneous Kirschner wires for distal radius fractures in an adult population: a meta-analysis.
    Youlden DJ; Sundaraj K; Smithers C
    ANZ J Surg; 2019 Jul; 89(7-8):821-826. PubMed ID: 30354018
    [TBL] [Abstract][Full Text] [Related]  

  • 17. External fixation versus internal fixation for unstable distal radius fractures: a systematic review and meta-analysis of comparative clinical trials.
    Wei DH; Poolman RW; Bhandari M; Wolfe VM; Rosenwasser MP
    J Orthop Trauma; 2012 Jul; 26(7):386-94. PubMed ID: 22108259
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparative study of clinical and radiologic outcomes of unstable colles type distal radius fractures in patients older than 70 years: nonoperative treatment versus volar locking plating.
    Arora R; Gabl M; Gschwentner M; Deml C; Krappinger D; Lutz M
    J Orthop Trauma; 2009 Apr; 23(4):237-42. PubMed ID: 19318865
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial.
    Costa ML; Achten J; Parsons NR; Rangan A; Griffin D; Tubeuf S; Lamb SE;
    BMJ; 2014 Aug; 349():g4807. PubMed ID: 25096595
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Open reduction and internal fixation versus external fixation for unstable distal radial fractures: a meta-analysis.
    Wang J; Yang Y; Ma J; Xing D; Zhu S; Ma B; Chen Y; Ma X
    Orthop Traumatol Surg Res; 2013 May; 99(3):321-31. PubMed ID: 23523527
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.