These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 24802620)
1. Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions. Galassi F; Brujic D; Rea M; Lambert N; Desouza N; Ristic M MAGMA; 2015 Feb; 28(1):33-48. PubMed ID: 24802620 [TBL] [Abstract][Full Text] [Related]
4. Automatic slice positioning (ASP) for passive real-time tracking of interventional devices using projection-reconstruction imaging with echo-dephasing (PRIDE). Patil S; Bieri O; Jhooti P; Scheffler K Magn Reson Med; 2009 Oct; 62(4):935-42. PubMed ID: 19585605 [TBL] [Abstract][Full Text] [Related]
5. Sub-pixel localisation of passive micro-coil fiducial markers in interventional MRI. Rea M; McRobbie D; Elhawary H; Tse ZT; Lamperth M; Young I MAGMA; 2009 Apr; 22(2):71-6. PubMed ID: 18802730 [TBL] [Abstract][Full Text] [Related]
6. Dynamic MRI scan plane control for passive tracking of instruments and devices. DiMaio SP; Samset E; Fischer G; Iordachita I; Fichtinger G; Jolesz F; Tempany CM Med Image Comput Comput Assist Interv; 2007; 10(Pt 2):50-8. PubMed ID: 18044552 [TBL] [Abstract][Full Text] [Related]
7. Phantom validation of coregistration of PET and CT for image-guided radiotherapy. Lavely WC; Scarfone C; Cevikalp H; Li R; Byrne DW; Cmelak AJ; Dawant B; Price RR; Hallahan DE; Fitzpatrick JM Med Phys; 2004 May; 31(5):1083-92. PubMed ID: 15191296 [TBL] [Abstract][Full Text] [Related]
8. Automatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions. Hamming NM; Daly MJ; Irish JC; Siewerdsen JH Med Phys; 2009 May; 36(5):1800-12. PubMed ID: 19544799 [TBL] [Abstract][Full Text] [Related]
9. 3D Segmentation with an application of level set-method using MRI volumes for image guided surgery. Bosnjak A; Montilla G; Villegas R; Jara I Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5263-6. PubMed ID: 18003195 [TBL] [Abstract][Full Text] [Related]
10. Measurement accuracy of different active tracking sequences for interventional MRI. Wech T; Shea SM; Barbot J; Vij K; Pan L; Lorenz CH; Patil S J Magn Reson Imaging; 2014 Aug; 40(2):490-5. PubMed ID: 24677517 [TBL] [Abstract][Full Text] [Related]
11. Improved statistical TRE model when using a reference frame. Wiles AD; Peters TM Med Image Comput Comput Assist Interv; 2007; 10(Pt 1):442-9. PubMed ID: 18051089 [TBL] [Abstract][Full Text] [Related]
12. Configurable automatic detection and registration of fiducial frames for device-to-image registration in MRI-guided prostate interventions. Tokuda J; Song SE; Tuncali K; Tempany C; Hata N Med Image Comput Comput Assist Interv; 2013; 16(Pt 3):355-62. PubMed ID: 24505781 [TBL] [Abstract][Full Text] [Related]
13. In vivo MR-tracking based on magnetic signature selective excitation. Felfoul O; Mathieu JB; Beaudoin G; Martel S IEEE Trans Med Imaging; 2008 Jan; 27(1):28-35. PubMed ID: 18270059 [TBL] [Abstract][Full Text] [Related]
14. Position and orientation measurement of susceptibility markers using spectrally selective spin-echo projections. Karimi H; Dominguez-Viqueira W; Cunningham CH Magn Reson Med; 2016 Nov; 76(5):1563-1573. PubMed ID: 26599342 [TBL] [Abstract][Full Text] [Related]
15. Three-dimensional tracking of occluded objects using integral imaging. Cho M; Javidi B Opt Lett; 2008 Dec; 33(23):2737-9. PubMed ID: 19037410 [TBL] [Abstract][Full Text] [Related]
16. Analytic expressions for fiducial and surface target registration error. Ma B; Ellis RE Med Image Comput Comput Assist Interv; 2006; 9(Pt 2):637-44. PubMed ID: 17354826 [TBL] [Abstract][Full Text] [Related]
17. High-precision absolute positioning of medical instruments in MRI systems. Aboussouan E; Martel S Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():743-6. PubMed ID: 17945995 [TBL] [Abstract][Full Text] [Related]