120 related articles for article (PubMed ID: 24806050)
1. Effects of kilovoltage, milliampere seconds, and focal spot size on image quality.
Kei Ma W; Hogg P; Norton S
Radiol Technol; 2014; 85(5):479-85. PubMed ID: 24806050
[TBL] [Abstract][Full Text] [Related]
2. Automated low-kilovoltage selection in pediatric computed tomography angiography: phantom study evaluating effects on radiation dose and image quality.
Siegel MJ; Ramirez-Giraldo JC; Hildebolt C; Bradley D; Schmidt B
Invest Radiol; 2013 Aug; 48(8):584-9. PubMed ID: 23563195
[TBL] [Abstract][Full Text] [Related]
3. Effects of radiographic techniques on the low-contrast detail detectability performance of digital radiography systems.
Alsleem H; U P; Mong KS; Davidson R
Radiol Technol; 2014; 85(6):614-22. PubMed ID: 25002641
[TBL] [Abstract][Full Text] [Related]
4. Multidetector computed tomography chest examinations with low-kilovoltage protocols in adults: effect on image quality and radiation dose.
Kim MJ; Park CH; Choi SJ; Hwang KH; Kim HS
J Comput Assist Tomogr; 2009; 33(3):416-21. PubMed ID: 19478637
[TBL] [Abstract][Full Text] [Related]
5. Comparing the standard knee X-ray exposure factor, 10 kV rule, and modified 10 kV rule techniques in digital radiography to reduce patient radiation dose without loss of image quality.
Wenman A; Lockwood P
Radiography (Lond); 2024 Mar; 30(2):574-581. PubMed ID: 38295494
[TBL] [Abstract][Full Text] [Related]
6. High kilovoltage digital exposure techniques and patient dosimetry.
Fauber TL; Cohen TF; Dempsey MC
Radiol Technol; 2011; 82(6):501-10. PubMed ID: 21771934
[TBL] [Abstract][Full Text] [Related]
7. Using 100- instead of 120-kVp computed tomography to diagnose pulmonary embolism almost halves the radiation dose with preserved diagnostic quality.
Björkdahl P; Nyman U
Acta Radiol; 2010 Apr; 51(3):260-70. PubMed ID: 20121673
[TBL] [Abstract][Full Text] [Related]
8. The effects of kilovoltage (kV) and milliampere seconds (mAs) values for SPECT attenuation correction: An anthropomorphic phantom study.
Kovan B
Appl Radiat Isot; 2024 Feb; 204():111118. PubMed ID: 38041989
[TBL] [Abstract][Full Text] [Related]
9. Effect of x-ray tube parameters and iodine concentration on image quality and radiation dose in cerebral pediatric and adult CT angiography: a phantom study.
Papadakis AE; Perisinakis K; Raissaki M; Damilakis J
Invest Radiol; 2013 Apr; 48(4):192-9. PubMed ID: 23344518
[TBL] [Abstract][Full Text] [Related]
10. General equations for optimal selection of diagnostic image acquisition parameters in clinical X-ray imaging.
Zheng X
Radiol Phys Technol; 2017 Dec; 10(4):415-421. PubMed ID: 28822074
[TBL] [Abstract][Full Text] [Related]
11. Radiographers' Ability to Detect Low-Contrast Detail in Digital Radiography Systems.
Alsleem H; Davidson R
Radiol Technol; 2015; 87(1):29-37. PubMed ID: 26377266
[TBL] [Abstract][Full Text] [Related]
12. Copper Filtration and kVp: Effect on Entrance Skin Exposure.
Barba J; Culp M
Radiol Technol; 2015; 86(6):603-9. PubMed ID: 26199432
[TBL] [Abstract][Full Text] [Related]
13. Reduction in radiation and contrast medium dose via optimization of low-kilovoltage CT protocols using a hybrid iterative reconstruction algorithm at 256-slice body CT: phantom study and clinical correlation.
Itatani R; Oda S; Utsunomiya D; Funama Y; Honda K; Katahira K; Morishita S; Yamamura S; Namimoto T; Yamashita Y
Clin Radiol; 2013 Mar; 68(3):e128-35. PubMed ID: 23245269
[TBL] [Abstract][Full Text] [Related]
14. Lowering kilovoltage to reduce radiation dose in contrast-enhanced abdominal CT: initial assessment of a prototype automated kilovoltage selection tool.
Hough DM; Fletcher JG; Grant KL; Fidler JL; Yu L; Geske JR; Carter RE; Raupach R; Schmidt B; Flohr T; McCollough CH
AJR Am J Roentgenol; 2012 Nov; 199(5):1070-7. PubMed ID: 23096181
[TBL] [Abstract][Full Text] [Related]
15. Focal spot motion of linear accelerators and its effect on portal image analysis.
Sonke JJ; Brand B; van Herk M
Med Phys; 2003 Jun; 30(6):1067-75. PubMed ID: 12852530
[TBL] [Abstract][Full Text] [Related]
16. Effect of radiation dose and iterative reconstruction on lung lesion conspicuity at MDCT: does one size fit all?
Botelho MP; Agrawal R; Gonzalez-Guindalini FD; Hart EM; Patel SK; Töre HG; Yaghmai V
Eur J Radiol; 2013 Nov; 82(11):e726-33. PubMed ID: 23928232
[TBL] [Abstract][Full Text] [Related]
17. Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space.
Hu XH; Ding XF; Wu RZ; Zhang MM
Clin Radiol; 2011 Nov; 66(11):1023-9. PubMed ID: 21861995
[TBL] [Abstract][Full Text] [Related]
18. Exposure variability and image quality in computed radiography.
Fauber TL
Radiol Technol; 2009; 80(3):209-15. PubMed ID: 19153197
[TBL] [Abstract][Full Text] [Related]
19. Virtual single-source computed tomography using dual-source acquisition: a new technique for the dose-neutral intraindividual comparison of different scan protocols.
Werncke T; Meyer BC; Wacker FK; von Falck C
Invest Radiol; 2014 Nov; 49(11):742-8. PubMed ID: 24918463
[TBL] [Abstract][Full Text] [Related]
20. Optimizing the Exposure Indicator as a Dose Management Strategy in Computed Radiography.
Seeram E; Davidson R; Bushong S; Swan H
Radiol Technol; 2016; 87(4):380-91. PubMed ID: 26952062
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]