149 related articles for article (PubMed ID: 24815355)
1. Non-invasive and invasive predictors of paravalvular regurgitation post CoreValve® stent prosthesis implantation in aortic valves.
Anger T; Bauer V; Plachtzik C; Geisler T; Gawaz M; Oberhoff M; Höher M
J Interv Cardiol; 2014 Jun; 27(3):275-83. PubMed ID: 24815355
[TBL] [Abstract][Full Text] [Related]
2. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement.
Khalique OK; Hahn RT; Gada H; Nazif TM; Vahl TP; George I; Kalesan B; Forster M; Williams MB; Leon MB; Einstein AJ; Pulerwitz TC; Pearson GD; Kodali SK
JACC Cardiovasc Interv; 2014 Aug; 7(8):885-94. PubMed ID: 25147034
[TBL] [Abstract][Full Text] [Related]
3. The aortic valve calcium nodule score (AVCNS) independently predicts paravalvular regurgitation after transcatheter aortic valve replacement (TAVR).
Azzalini L; Ghoshhajra BB; Elmariah S; Passeri JJ; Inglessis I; Palacios IF; Abbara S
J Cardiovasc Comput Tomogr; 2014; 8(2):131-40. PubMed ID: 24661826
[TBL] [Abstract][Full Text] [Related]
4. Predictors of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation for Aortic Stenosis Using New-Generation Balloon-Expandable SAPIEN 3.
Kaneko H; Hoelschermann F; Tambor G; Yoon SH; Neuss M; Butter C
Am J Cardiol; 2017 Feb; 119(4):618-622. PubMed ID: 28010874
[TBL] [Abstract][Full Text] [Related]
5. Predictors of paravalvular aortic regurgitation following self-expanding Medtronic CoreValve implantation: the role of annulus size, degree of calcification, and balloon size during pre-implantation valvuloplasty and implant depth.
Ali OF; Schultz C; Jabbour A; Rubens M; Mittal T; Mohiaddin R; Davies S; Di Mario C; Van der Boon R; Ahmad AS; Amrani M; Moat N; De Jaegere PP; Dalby M
Int J Cardiol; 2015 Jan; 179():539-45. PubMed ID: 25466563
[TBL] [Abstract][Full Text] [Related]
6. The extent of aortic annulus calcification is a predictor of postprocedural eccentricity and paravalvular regurgitation: a pre- and postinterventional cardiac computed tomography angiography study.
Bekeredjian R; Bodingbauer D; Hofmann NP; Greiner S; Schuetz M; Geis NA; Kauczor HU; Bryant M; Chorianopoulos E; Pleger ST; Mereles D; Katus HA; Korosoglou G
J Invasive Cardiol; 2015 Mar; 27(3):172-80. PubMed ID: 25740972
[TBL] [Abstract][Full Text] [Related]
7. Aortic Valve Calcium Volume Predicts Paravalvular Regurgitation and the Need for Balloon Post-Dilatation After Transcatheter Aortic Valve Implantation.
Fonseca P; Figueiredo B; Almeida C; Almeida J; Bettencourt N; Sampaio F; Ferreira N; Gonçalves H; Braga P; Ribeiro VG
J Interv Cardiol; 2016 Feb; 29(1):117-23. PubMed ID: 26728663
[TBL] [Abstract][Full Text] [Related]
8. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
[TBL] [Abstract][Full Text] [Related]
9. Paravalvular leak after transcatheter aortic valve implantation: is it anatomically predictable or procedurally determined? MDCT study.
Sakrana AA; Nasr MM; Ashamallah GA; Abuelatta RA; Naeim HA; Tahlawi ME
Clin Radiol; 2016 Nov; 71(11):1095-103. PubMed ID: 27612848
[TBL] [Abstract][Full Text] [Related]
10. Comparison of aortic valve annulus diameter determination through 3-dimensional transesophageal echo with cardiac MDCT and assessment of predictors for annulus sizing.
Anger T; Schmid M; Geisler T; Gawaz MP; Oberhoff M; Höher M
J Heart Valve Dis; 2015 Mar; 24(2):239-46. PubMed ID: 26204693
[TBL] [Abstract][Full Text] [Related]
11. Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement.
Buellesfeld L; Stortecky S; Heg D; Gloekler S; Meier B; Wenaweser P; Windecker S
EuroIntervention; 2014 Oct; 10(6):732-8. PubMed ID: 25330505
[TBL] [Abstract][Full Text] [Related]
12. Aortic annulus area assessment by multidetector computed tomography for predicting paravalvular regurgitation in patients undergoing balloon-expandable transcatheter aortic valve implantation: a comparison with transthoracic and transesophageal echocardiography.
Pontone G; Andreini D; Bartorelli AL; Bertella E; Cortinovis S; Mushtaq S; Annoni A; Formenti A; Baggiano A; Conte E; Tamborini G; Muratori M; Gripari P; Bovis F; Veglia F; Foti C; Alamanni F; Ballerini G; Fiorentini C; Pepi M
Am Heart J; 2012 Oct; 164(4):576-84. PubMed ID: 23067917
[TBL] [Abstract][Full Text] [Related]
13. Impact of Different Iterations of Devices and Degree of Aortic Valve Calcium on Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation.
Kong WK; van Rosendael PJ; van der Kley F; de Weger A; Kamperidis V; Regeer MV; Marsan NA; Bax JJ; Delgado V
Am J Cardiol; 2016 Aug; 118(4):567-71. PubMed ID: 27328953
[TBL] [Abstract][Full Text] [Related]
14. Predictors of Paravalvular Regurgitation After Implantation of the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Valve (from the REPRISE II Trial Extended Cohort).
Blackman DJ; Meredith IT; Dumonteil N; Tchétché D; Hildick-Smith D; Spence MS; Walters DL; Harnek J; Worthley SG; Rioufol G; Lefèvre T; Houle VM; Allocco DJ; Dawkins KD
Am J Cardiol; 2017 Jul; 120(2):292-299. PubMed ID: 28535962
[TBL] [Abstract][Full Text] [Related]
15. Device landing zone calcification and its impact on residual regurgitation after transcatheter aortic valve implantation with different devices.
Seiffert M; Fujita B; Avanesov M; Lunau C; Schön G; Conradi L; Prashovikj E; Scholtz S; Börgermann J; Scholtz W; Schäfer U; Lund G; Ensminger S; Treede H
Eur Heart J Cardiovasc Imaging; 2016 May; 17(5):576-84. PubMed ID: 26160399
[TBL] [Abstract][Full Text] [Related]
16. Dynamic characterization of aortic annulus geometry and morphology with multimodality imaging: predictive value for aortic regurgitation after transcatheter aortic valve replacement.
Masri A; Schoenhagen P; Svensson L; Kapadia SR; Griffin BP; Tuzcu EM; Desai MY
J Thorac Cardiovasc Surg; 2014 Jun; 147(6):1847-54. PubMed ID: 23870156
[TBL] [Abstract][Full Text] [Related]
17. Sutureless Aortic Valve Prosthesis Sizing: Estimation and Prediction Using Multidetector-Row Computed Tomography.
Margaryan R; Kallushi E; Gilmanov D; Micelli A; Murzi M; Solinas M; Cerillo AG; Glauber M
Innovations (Phila); 2015; 10(4):230-5; discussion 235. PubMed ID: 26371451
[TBL] [Abstract][Full Text] [Related]
18. Aortic root dimensions among patients with severe aortic stenosis undergoing transcatheter aortic valve replacement.
Buellesfeld L; Stortecky S; Kalesan B; Gloekler S; Khattab AA; Nietlispach F; Delfine V; Huber C; Eberle B; Meier B; Wenaweser P; Windecker S
JACC Cardiovasc Interv; 2013 Jan; 6(1):72-83. PubMed ID: 23347864
[TBL] [Abstract][Full Text] [Related]
19. Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation.
Takagi K; Latib A; Al-Lamee R; Mussardo M; Montorfano M; Maisano F; Godino C; Chieffo A; Alfieri O; Colombo A
Catheter Cardiovasc Interv; 2011 Sep; 78(3):432-43. PubMed ID: 21793168
[TBL] [Abstract][Full Text] [Related]
20. Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve.
Wong DT; Bertaso AG; Liew GY; Thomson VS; Cunnington MS; Richardson JD; Gooley R; Lockwood S; Meredith IT; Worthley MI; Worthley SG
J Invasive Cardiol; 2013 Apr; 25(4):190-5. PubMed ID: 23549493
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]