230 related articles for article (PubMed ID: 24816936)
1. Cardiac valve calcifications on low-dose unenhanced ungated chest computed tomography: inter-observer and inter-examination reliability, agreement and variability.
van Hamersvelt RW; Willemink MJ; Takx RA; Eikendal AL; Budde RP; Leiner T; Mol CP; Isgum I; de Jong PA
Eur Radiol; 2014 Jul; 24(7):1557-64. PubMed ID: 24816936
[TBL] [Abstract][Full Text] [Related]
2. Visual scoring of aortic valve calcifications on low-dose CT in lung cancer screening.
Zhu Y; Wang Y; Gioia WE; Yip R; Jirapatnakul AC; Chung MS; Yankelevitz DF; Henschke CI
Eur Radiol; 2020 May; 30(5):2658-2668. PubMed ID: 32040729
[TBL] [Abstract][Full Text] [Related]
3. Inter-observer and inter-examination variability of manual vertebral bone attenuation measurements on computed tomography.
Pompe E; de Jong PA; de Jong WU; Takx RA; Eikendal AL; Willemink MJ; Oudkerk M; Budde RP; Lammers JW; Mohamed Hoesein FA
Eur Radiol; 2016 Sep; 26(9):3046-53. PubMed ID: 26801161
[TBL] [Abstract][Full Text] [Related]
4. Combined aortic valve and coronary artery calcifications in lung cancer screening as predictors of death from cardiovascular disease.
Zhu Y; Yip R; Shemesh J; Jirapatnakul AC; Yankelevitz DF; Henschke CI
Eur Radiol; 2020 Dec; 30(12):6847-6857. PubMed ID: 32725329
[TBL] [Abstract][Full Text] [Related]
5. Reproducibility of aortic valve calcification scoring with computed tomography - An interplatform analysis.
Eberhard M; Hinzpeter R; Polacin M; Morsbach F; Maisano F; Nietlispach F; Nguyen-Kim TDL; Tanner FC; Alkadhi H
J Cardiovasc Comput Tomogr; 2019; 13(2):92-98. PubMed ID: 30665879
[TBL] [Abstract][Full Text] [Related]
6. Quantification of Aortic Valve Calcifications Detected During Lung Cancer-Screening CT Helps Stratify Subjects Necessitating Echocardiography for Aortic Stenosis Diagnosis.
Lee HY; Kim SM; Lee KS; Park SW; Chung MJ; Cho H; Jung JI; Jang HW; Jung SH; Goo J
Medicine (Baltimore); 2016 May; 95(19):e3710. PubMed ID: 27175713
[TBL] [Abstract][Full Text] [Related]
7. Reproducibility of CT measurements of aortic valve calcification, mitral annulus calcification, and aortic wall calcification in the multi-ethnic study of atherosclerosis.
Budoff MJ; Takasu J; Katz R; Mao S; Shavelle DM; O'Brien KD; Blumenthal RS; Carr JJ; Kronmal R
Acad Radiol; 2006 Feb; 13(2):166-72. PubMed ID: 16428051
[TBL] [Abstract][Full Text] [Related]
8. Aortic valve calcifications on chest films: how much calcium do I need?
Mahnken AH; Dohmen G; Koos R
Acta Cardiol; 2011 Aug; 66(4):505-8. PubMed ID: 21894808
[TBL] [Abstract][Full Text] [Related]
9. Coronary artery calcification correlates with the presence and severity of valve calcification.
Koulaouzidis G; Nicoll R; MacArthur T; Jenkins PJ; Henein MY
Int J Cardiol; 2013 Oct; 168(6):5263-6. PubMed ID: 23993324
[TBL] [Abstract][Full Text] [Related]
10. Evaluation and clinical implications of aortic valve calcification measured by electron-beam computed tomography.
Messika-Zeitoun D; Aubry MC; Detaint D; Bielak LF; Peyser PA; Sheedy PF; Turner ST; Breen JF; Scott C; Tajik AJ; Enriquez-Sarano M
Circulation; 2004 Jul; 110(3):356-62. PubMed ID: 15249504
[TBL] [Abstract][Full Text] [Related]
11. Quantifying Aortic Valve Calcification using Coronary Computed Tomography Angiography.
Alqahtani AM; Boczar KE; Kansal V; Chan K; Dwivedi G; Chow BJ
J Cardiovasc Comput Tomogr; 2017; 11(2):99-104. PubMed ID: 28209366
[TBL] [Abstract][Full Text] [Related]
12. Mitral annular calcification in the elderly - Quantitative assessment.
Eberhard M; Schönenberger ALN; Hinzpeter R; Euler A; Sokolska J; Weber L; Kuzo N; Manka R; Kasel AM; Tanner FC; Alkadhi H
J Cardiovasc Comput Tomogr; 2021; 15(2):161-166. PubMed ID: 32798185
[TBL] [Abstract][Full Text] [Related]
13. Quantification of aortic valve calcification using multislice spiral computed tomography: comparison with atomic absorption spectroscopy.
Koos R; Mahnken AH; Kühl HP; Mühlenbruch G; Mevissen V; Stork L; Dronskowski R; Langebartels G; Autschbach R; Ortlepp JR
Invest Radiol; 2006 May; 41(5):485-9. PubMed ID: 16625112
[TBL] [Abstract][Full Text] [Related]
14. Association between Aortic Valve Calcification Progression and Coronary Atherosclerotic Plaque Volume Progression in the PARADIGM Registry.
Lee SE; Sung JM; Andreini D; Al-Mallah MH; Budoff MJ; Cademartiri F; Chinnaiyan K; Choi JH; Chun EJ; Conte E; Gottlieb I; Hadamitzky M; Kim YJ; Lee BK; Leipsic JA; Maffei E; Marques H; de Araújo Gonçalves P; Pontone G; Shin S; Stone PH; Samady H; Virmani R; Narula J; Berman DS; Shaw LJ; Bax JJ; Lin FY; Min JK; Chang HJ
Radiology; 2021 Jul; 300(1):79-86. PubMed ID: 33973837
[TBL] [Abstract][Full Text] [Related]
15. Automatic Calcium Scoring in Low-Dose Chest CT Using Deep Neural Networks With Dilated Convolutions.
Lessmann N; van Ginneken B; Zreik M; de Jong PA; de Vos BD; Viergever MA; Isgum I
IEEE Trans Med Imaging; 2018 Feb; 37(2):615-625. PubMed ID: 29408789
[TBL] [Abstract][Full Text] [Related]
16. Aortic valve type and calcification as assessed by transthoracic and transoesophageal echocardiography.
Yousry M; Rickenlund A; Petrini J; Jenner J; Liska J; Eriksson P; Franco-Cereceda A; Eriksson MJ; Caidahl K
Clin Physiol Funct Imaging; 2015 Jul; 35(4):306-13. PubMed ID: 24889906
[TBL] [Abstract][Full Text] [Related]
17. Association between aortic valve calcification measured on non-contrast computed tomography and aortic valve stenosis in the general population.
Paulsen NH; Carlsen BB; Dahl JS; Carter-Storch R; Christensen NL; Khurrami L; Møller JE; Lindholt JS; Diederichsen AC
J Cardiovasc Comput Tomogr; 2016; 10(4):309-15. PubMed ID: 27247181
[TBL] [Abstract][Full Text] [Related]
18. Aortic root, not valve, calcification correlates with coronary artery calcification in patients with severe aortic stenosis: A two-center study.
Henein M; Hällgren P; Holmgren A; Sörensen K; Ibrahimi P; Kofoed KF; Larsen LH; Hassager C
Atherosclerosis; 2015 Dec; 243(2):631-7. PubMed ID: 26551591
[TBL] [Abstract][Full Text] [Related]
19. Assessment of aortic valve calcium load by multidetector computed tomography. Anatomical validation, impact of scanner settings and incremental diagnostic value.
Boulif J; Gerber B; Slimani A; Lazam S; de Meester C; Piérard S; Pasquet A; Pouleur AC; Vancraeynest D; El Khoury G; de Kerchove L; Noirhomme P; Vanoverschelde JL
J Cardiovasc Comput Tomogr; 2017; 11(5):360-366. PubMed ID: 28803719
[TBL] [Abstract][Full Text] [Related]
20. Impact of aortic valve calcification, as measured by MDCT, on survival in patients with aortic stenosis: results of an international registry study.
Clavel MA; Pibarot P; Messika-Zeitoun D; Capoulade R; Malouf J; Aggarval S; Araoz PA; Michelena HI; Cueff C; Larose E; Miller JD; Vahanian A; Enriquez-Sarano M
J Am Coll Cardiol; 2014 Sep; 64(12):1202-13. PubMed ID: 25236511
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]