BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

474 related articles for article (PubMed ID: 24828985)

  • 1. Biomechanical analysis of a new carbon fiber/flax/epoxy bone fracture plate shows less stress shielding compared to a standard clinical metal plate.
    Bagheri ZS; Tavakkoli Avval P; Bougherara H; Aziz MS; Schemitsch EH; Zdero R
    J Biomech Eng; 2014 Sep; 136(9):091002. PubMed ID: 24828985
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On optimization of a composite bone plate using the selective stress shielding approach.
    Samiezadeh S; Tavakkoli Avval P; Fawaz Z; Bougherara H
    J Mech Behav Biomed Mater; 2015 Feb; 42():138-53. PubMed ID: 25482217
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical analysis using infrared thermography of a traditional metal plate versus a carbon fibre/epoxy plate for Vancouver B1 femur fractures.
    Siddiqui FS; Shah S; Nicayenzi B; Schemitsch EH; Zdero R; Bougherara H
    Proc Inst Mech Eng H; 2014 Jan; 228(1):107-13. PubMed ID: 23982064
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical fatigue analysis of an advanced new carbon fiber/flax/epoxy plate for bone fracture repair using conventional fatigue tests and thermography.
    Bagheri ZS; El Sawi I; Bougherara H; Zdero R
    J Mech Behav Biomed Mater; 2014 Jul; 35():27-38. PubMed ID: 24727574
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A biomechanical study on the laminate stacking sequence in composite bone plates for vancouver femur B1 fracture fixation.
    Dhason R; Roy S; Datta S
    Comput Methods Programs Biomed; 2020 Nov; 196():105680. PubMed ID: 32763643
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical fatigue analysis of an advanced new carbon fiber/flax/epoxy plate for bone fracture repair using conventional fatigue tests and thermography.
    Bagheri ZS; El Sawi I; Bougherara H; Zdero R
    J Mech Behav Biomed Mater; 2014 Jul; 35():27-38. PubMed ID: 24918250
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Osteogenesis and cytotoxicity of a new Carbon Fiber/Flax/Epoxy composite material for bone fracture plate applications.
    Bagheri ZS; Giles E; El Sawi I; Amleh A; Schemitsch EH; Zdero R; Bougherara H
    Mater Sci Eng C Mater Biol Appl; 2015 Jan; 46():435-42. PubMed ID: 25492008
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical properties of an advanced new carbon/flax/epoxy composite material for bone plate applications.
    Bagheri ZS; El Sawi I; Schemitsch EH; Zdero R; Bougherara H
    J Mech Behav Biomed Mater; 2013 Apr; 20():398-406. PubMed ID: 23499250
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical properties of an intact, injured, repaired, and healed femur: an experimental and computational study.
    Ebrahimi H; Rabinovich M; Vuleta V; Zalcman D; Shah S; Dubov A; Roy K; Siddiqui FS; H Schemitsch E; Bougherara H; Zdero R
    J Mech Behav Biomed Mater; 2012 Dec; 16():121-35. PubMed ID: 23182385
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of composite bone plates in Vancouver femur B1 fracture fixation after post-operative, and healed bone stages: A finite element study.
    Dhason R; Roy S; Datta S
    Proc Inst Mech Eng H; 2022 Sep; 236(9):1288-1296. PubMed ID: 35920405
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of the bone-plate material and the presence of a gap between the fractured bone and plate on the predicted stresses at the fractured bone.
    Fouad H
    Med Eng Phys; 2010 Sep; 32(7):783-9. PubMed ID: 20627657
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position.
    Dubov A; Kim SY; Shah S; Schemitsch EH; Zdero R; Bougherara H
    Proc Inst Mech Eng H; 2011 Sep; 225(9):857-65. PubMed ID: 22070023
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture.
    Pengrung N; Lakdee N; Puncreobutr C; Lohwongwatana B; Sa-Ngasoongsong P
    BMC Musculoskelet Disord; 2019 Oct; 20(1):465. PubMed ID: 31640668
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate.
    Heiney JP; Barnett MD; Vrabec GA; Schoenfeld AJ; Baji A; Njus GO
    J Trauma; 2009 Feb; 66(2):443-9. PubMed ID: 19204519
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical Analysis Using FEA and Experiments of Metal Plate and Bone Strut Repair of a Femur Midshaft Segmental Defect.
    Coquim J; Clemenzi J; Salahi M; Sherif A; Tavakkoli Avval P; Shah S; Schemitsch EH; Bagheri ZS; Bougherara H; Zdero R
    Biomed Res Int; 2018; 2018():4650308. PubMed ID: 30420962
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical assessment of composite versus metallic intramedullary nailing system in femoral shaft fractures: A finite element study.
    Samiezadeh S; Tavakkoli Avval P; Fawaz Z; Bougherara H
    Clin Biomech (Bristol, Avon); 2014 Aug; 29(7):803-10. PubMed ID: 24951320
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty.
    Chen SH; Chiang MC; Hung CH; Lin SC; Chang HW
    Knee; 2014 Jan; 21(1):224-31. PubMed ID: 23582376
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Orbital stress analysis, Part IV: Use of a "stiffness-graded" biodegradable implants to repair orbital blow-out fracture.
    Al-Sukhun J; Penttilä H; Ashammakhi N
    J Craniofac Surg; 2012 Jan; 23(1):126-30. PubMed ID: 22337388
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates.
    Ganesh VK; Ramakrishna K; Ghista DN
    Biomed Eng Online; 2005 Jul; 4():46. PubMed ID: 16045807
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration of its potential benefits on synthetic femur model with supportive hierarchical nonlinear hyperelastic finite element analysis.
    Latifi MH; Ganthel K; Rukmanikanthan S; Mansor A; Kamarul T; Bilgen M
    Biomed Eng Online; 2012 Apr; 11():23. PubMed ID: 22545650
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 24.