These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 24831994)

  • 21. Optical coherence tomography guidance for percutaneous coronary intervention with bioresorbable scaffolds.
    Caiazzo G; Longo G; Giavarini A; Kilic ID; Fabris E; Serdoz R; Mattesini A; Foin N; Secco GG; De Rosa S; Indolfi C; Di Mario C
    Int J Cardiol; 2016 Oct; 221():352-8. PubMed ID: 27404705
    [TBL] [Abstract][Full Text] [Related]  

  • 22. In vivo comparison of lumen dimensions measured by time domain-, and frequency domain-optical coherence tomography, and intravascular ultrasound.
    Kim SJ; Lee H; Kato K; Yonetsu T; Jang IK
    Int J Cardiovasc Imaging; 2013 Jun; 29(5):967-75. PubMed ID: 23292151
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Serial invasive imaging follow-up of the first clinical experience with the Magmaris magnesium bioresorbable scaffold.
    Tovar Forero MN; van Zandvoort L; Masdjedi K; Diletti R; Wilschut J; de Jaegere PP; Zijlstra F; Van Mieghem NM; Daemen J
    Catheter Cardiovasc Interv; 2020 Feb; 95(2):226-231. PubMed ID: 31033171
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Randomized Comparison Between Everolimus-Eluting Bioresorbable Scaffold and Metallic Stent: Multimodality Imaging Through 3 Years.
    Onuma Y; Honda Y; Asano T; Shiomi H; Kozuma K; Ozaki Y; Namiki A; Yasuda S; Ueno T; Ando K; Furuya J; Hanaoka KI; Tanabe K; Okada K; Kitahara H; Ono M; Kusano H; Rapoza R; Simonton C; Popma JJ; Stone GW; Fitzgerald PJ; Serruys PW; Kimura T
    JACC Cardiovasc Interv; 2020 Jan; 13(1):116-127. PubMed ID: 31918929
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Optical Coherence Tomography for Coronary Bioresorbable Vascular Scaffold Implantation: A Randomized Controlled Trial.
    Lee SY; Kang DY; Hong SJ; Ahn JM; Ahn CM; Park DW; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Park SJ; Hong MK
    Circ Cardiovasc Interv; 2020 Jan; 13(1):e008383. PubMed ID: 32525410
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Reproducibility of serial optical coherence tomography measurements for lumen area and plaque components in humans (The CLI-VAR [Centro per la Lotta Contro l'Infarto-variability] II study).
    Paoletti G; Marco V; Romagnoli E; Gatto L; Fedele S; Mangiameli A; Ramazzotti V; Castriota F; Di Vito L; Ricciardi A; Prati F
    Int J Cardiovasc Imaging; 2016 Mar; 32(3):381-7. PubMed ID: 26585751
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Neointimal response to everolimus-eluting bioresorbable scaffolds implanted at bifurcating coronary segments: insights from optical coherence tomography.
    Sato T; Jose J; El-Mawardy M; Sulimov DS; Tölg R; Richardt G; Abdel-Wahab M
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):169-175. PubMed ID: 27757563
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Serial assessment of vessel interactions after drug-eluting stent implantation in unprotected distal left main coronary artery disease using frequency-domain optical coherence tomography.
    Fujino Y; Attizzani GF; Bezerra HG; Wang W; Tahara S; Yamamoto H; Chamie D; Kanaya T; Mehanna E; Takagi K; Nakamura S; Costa MA
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1035-45. PubMed ID: 24156964
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Impact of strut thickness on acute mechanical performance: A comparison study using optical coherence tomography between DESolve 150 and DESolve 100.
    Boeder NF; Dörr O; Bauer T; Mattesini A; Elsässer A; Liebetrau C; Achenbach S; Hamm CW; Nef HM
    Int J Cardiol; 2017 Nov; 246():74-79. PubMed ID: 28579164
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Serial 3-Dimensional Optical Coherence Tomography Assessment of Jailed Side-Branch by Second-Generation Drug-Eluting Absorbable Metal Scaffold (from the BIOSOLVE-II Trial).
    Ozaki Y; Garcia-Garcia HM; Hideo-Kajita A; Kuku KO; Haude M; Ince H; Abizaid A; Tölg R; Lemos PA; von Birgelen C; Christiansen EH; Wijns W; Escaned J; Waksman R
    Am J Cardiol; 2019 Apr; 123(7):1044-1051. PubMed ID: 30683424
    [TBL] [Abstract][Full Text] [Related]  

  • 31. New insights on acute expansion and longitudinal elongation of bioresorbable vascular scaffolds in vivo and at bench test: a note of caution on reliance to compliance charts and nominal length.
    Attizzani GF; Ohno Y; Capodanno D; Francaviglia B; Grasso C; Sgroi C; Wang W; Fujino Y; Ganocy SJ; Longo G; Tamburino CI; Di Salvo M; La Manna A; Capranzano P; Tamburino C
    Catheter Cardiovasc Interv; 2015 Mar; 85(4):E99-E107. PubMed ID: 25154722
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Side branch complication after a single-stent crossover technique: prediction with frequency domain optical coherence tomography.
    Watanabe M; Uemura S; Sugawara Y; Ueda T; Soeda T; Takeda Y; Kawata H; Kawakami R; Saito Y
    Coron Artery Dis; 2014 Jun; 25(4):321-9. PubMed ID: 24769514
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Assessment of bioresorbable scaffold with a novel high-definition 60 MHz IVUS imaging system: Comparison with 40-MHz IVUS referenced to optical coherence tomography.
    Okada K; Kitahara H; Mitsutake Y; Tanaka S; Kimura T; Yock PG; Fitzgerald PJ; Ikeno F; Honda Y
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):874-883. PubMed ID: 28707349
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Hemodynamic analysis of a novel bioresorbable scaffold in porcine coronary artery model.
    Tenekecioglu E; Torii R; Bourantas CV; Cavalcante R; Sotomi Y; Zeng Y; Collet C; Crake T; Abizaid A; Onuma Y; Su S; Santoso T; Serruys PW
    Catheter Cardiovasc Interv; 2018 May; 91(6):1084-1091. PubMed ID: 28843033
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Intra- and interobserver reliability and intra-catheter reproducibility using frequency domain optical coherence tomography for the evaluation of morphometric stent parameters and qualitative assessment of stent strut coverage.
    Antonsen L; Thayssen P; Junker A; Veien KT; Hansen HS; Hansen KN; Hougaard M; Jensen LO
    Cardiovasc Revasc Med; 2015 Dec; 16(8):469-77. PubMed ID: 26475731
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Is high pressure postdilation safe in bioresorbable vascular scaffolds? Optical coherence tomography observations after noncompliant balloons inflated at more than 24 atmospheres.
    Fabris E; Caiazzo G; Kilic ID; Serdoz R; Secco GG; Sinagra G; Lee R; Foin N; Di Mario C
    Catheter Cardiovasc Interv; 2016 Apr; 87(5):839-46. PubMed ID: 26370357
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Serial Assessment of Tissue Precursors and Progression of Coronary Calcification Analyzed by Fusion of IVUS and OCT: 5-Year Follow-Up of Scaffolded and Nonscaffolded Arteries.
    Zeng Y; Tateishi H; Cavalcante R; Tenekecioglu E; Suwannasom P; Sotomi Y; Collet C; Nie S; Jonker H; Dijkstra J; Radu MD; Räber L; McClean DR; van Geuns RJ; Christiansen EH; Fahrni T; Koolen J; Onuma Y; Bruining N; Serruys PW
    JACC Cardiovasc Imaging; 2017 Oct; 10(10 Pt A):1151-1161. PubMed ID: 28330651
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Bioresorbable vascular scaffold treatment induces the formation of neointimal cap that seals the underlying plaque without compromising the luminal dimensions: a concept based on serial optical coherence tomography data.
    Bourantas CV; Serruys PW; Nakatani S; Zhang YJ; Farooq V; Diletti R; Ligthart J; Sheehy A; van Geuns RJ; McClean D; Chevalier B; Windecker S; Koolen J; Ormiston J; Whitbourn R; Rapoza R; Veldhof S; Onuma Y; Garcia-Garcia HM
    EuroIntervention; 2015 Nov; 11(7):746-56. PubMed ID: 25308301
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Inter-scan reproducibility of geometric coronary artery measurements using frequency-domain optical coherence tomography.
    Orii M; Kubo T; Tanaka A; Kitabata H; Ino Y; Shiono Y; Shimamura K; Aoki H; Ohta S; Ozaki Y; Ishibashi K; Yamano T; Tanimoto T; Yamaguchi T; Hirata K; Imanishi T; Akasaka T
    Int Heart J; 2013; 54(2):64-7. PubMed ID: 23676364
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Scaffold thrombosis following implantation of the ABSORB BVS in routine clinical practice: Insight into possible mechanisms from optical coherence tomography.
    Kraak RP; Kajita AH; Garcia-Garcia HM; Henriques JPS; Piek JJ; Arkenbout EK; van der Schaaf RJ; Tijssen JGP; de Winter RJ; Wykrzykowska JJ
    Catheter Cardiovasc Interv; 2018 Aug; 92(2):E106-E114. PubMed ID: 29332307
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.