These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Mobile magnetic particles as solid-supports for rapid surface-based bioanalysis in continuous flow. Peyman SA; Iles A; Pamme N Lab Chip; 2009 Nov; 9(21):3110-7. PubMed ID: 19823727 [TBL] [Abstract][Full Text] [Related]
3. On-chip determination of C-reactive protein using magnetic particles in continuous flow. Phurimsak C; Tarn MD; Peyman SA; Greenman J; Pamme N Anal Chem; 2014 Nov; 86(21):10552-9. PubMed ID: 25275437 [TBL] [Abstract][Full Text] [Related]
4. C-reactive protein and interleukin 6 microfluidic immunoassays with on-chip pre-stored reagents and centrifugo-pneumatic liquid control. Zhao Y; Czilwik G; Klein V; Mitsakakis K; Zengerle R; Paust N Lab Chip; 2017 May; 17(9):1666-1677. PubMed ID: 28426080 [TBL] [Abstract][Full Text] [Related]
5. Sequential push-pull pumping mechanism for washing and evacuation of an immunoassay reaction chamber on a microfluidic CD platform. Thio TH; Ibrahim F; Al-Faqheri W; Soin N; Kahar Bador M; Madou M PLoS One; 2015; 10(4):e0121836. PubMed ID: 25853411 [TBL] [Abstract][Full Text] [Related]
6. On-Chip Magnetic Particle-Based Immunoassays Using Multilaminar Flow for Clinical Diagnostics. Tarn MD; Pamme N Methods Mol Biol; 2017; 1547():69-83. PubMed ID: 28044288 [TBL] [Abstract][Full Text] [Related]
7. A compact and integrated immunoassay with on-chip dispensing and magnetic particle handling. Zirath H; Peham JR; Schnetz G; Coll A; Brandhoff L; Spittler A; Vellekoop MJ; Redl H Biomed Microdevices; 2016 Feb; 18(1):16. PubMed ID: 26842948 [TBL] [Abstract][Full Text] [Related]
8. Full on-chip nanoliter immunoassay by geometrical magnetic trapping of nanoparticle chains. Lacharme F; Vandevyver C; Gijs MA Anal Chem; 2008 Apr; 80(8):2905-10. PubMed ID: 18348542 [TBL] [Abstract][Full Text] [Related]
9. Novel concept of washing for microfluidic paper-based analytical devices based on capillary force of paper substrates. Mohammadi S; Busa LS; Maeki M; Mohamadi RM; Ishida A; Tani H; Tokeshi M Anal Bioanal Chem; 2016 Nov; 408(27):7559-7563. PubMed ID: 27544520 [TBL] [Abstract][Full Text] [Related]
10. Highly Sensitive Two-Dimensional Paper Network Incorporating Biotin-Streptavidin for the Detection of Malaria. Grant BD; Smith CA; Karvonen K; Richards-Kortum R Anal Chem; 2016 Mar; 88(5):2553-7. PubMed ID: 26824718 [TBL] [Abstract][Full Text] [Related]
11. Rapid, multistep on-chip DNA hybridisation in continuous flow on magnetic particles. Vojtísek M; Iles A; Pamme N Biosens Bioelectron; 2010 May; 25(9):2172-6. PubMed ID: 20181469 [TBL] [Abstract][Full Text] [Related]
12. Magnetic particle-scanning for ultrasensitive immunodetection on-chip. Cornaglia M; Trouillon R; Tekin HC; Lehnert T; Gijs MA Anal Chem; 2014 Aug; 86(16):8213-23. PubMed ID: 25072276 [TBL] [Abstract][Full Text] [Related]
13. Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples. Bhattacharyya A; Klapperich CM Biomed Microdevices; 2007 Apr; 9(2):245-51. PubMed ID: 17165125 [TBL] [Abstract][Full Text] [Related]
14. Autonomous capillary system for one-step immunoassays. Zimmermann M; Hunziker P; Delamarche E Biomed Microdevices; 2009 Feb; 11(1):1-8. PubMed ID: 18810643 [TBL] [Abstract][Full Text] [Related]
15. Nets of biotin-derived gold nanoparticles as a label for the C-reactive protein immunoassay. Kokorina AA; Rashchevskaya RO; Goryacheva IY Anal Bioanal Chem; 2021 Nov; 413(27):6867-6875. PubMed ID: 34559243 [TBL] [Abstract][Full Text] [Related]
16. DNA-bridged bioconjugation of fluorescent quantum dots for highly sensitive microfluidic protein chips. Hu M; He Y; Song S; Yan J; Lu HT; Weng LX; Wang LH; Fan C Chem Commun (Camb); 2010 Sep; 46(33):6126-8. PubMed ID: 20664878 [TBL] [Abstract][Full Text] [Related]
17. Detection of biomolecular interaction between biotin and streptavidin on a self-assembled monolayer using magnetic nanoparticles. Arakaki A; Hideshima S; Nakagawa T; Niwa D; Tanaka T; Matsunaga T; Osaka T Biotechnol Bioeng; 2004 Nov; 88(4):543-6. PubMed ID: 15384052 [TBL] [Abstract][Full Text] [Related]
18. A polymer-based microfluidic device for immunosensing biochips. Soo Ko J; Yoon HC; Yang H; Pyo HB; Hyo Chung K; Jin Kim S; Tae Kim Y Lab Chip; 2003 May; 3(2):106-13. PubMed ID: 15100791 [TBL] [Abstract][Full Text] [Related]
19. Microvalves actuated sandwich immunoassay on an integrated microfluidic system. Gao X; Jiang L; Su X; Qin J; Lin B Electrophoresis; 2009 Jul; 30(14):2481-7. PubMed ID: 19639569 [TBL] [Abstract][Full Text] [Related]
20. On-chip microlasers for biomolecular detection via highly localized deposition of a multifunctional phospholipid ink. Bog U; Laue T; Grossmann T; Beck T; Wienhold T; Richter B; Hirtz M; Fuchs H; Kalt H; Mappes T Lab Chip; 2013 Jul; 13(14):2701-7. PubMed ID: 23649356 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]