1. Noninvasive pressure difference mapping derived from 4D flow MRI in patients with unrepaired and repaired aortic coarctation.
Rengier F; Delles M; Eichhorn J; Azad YJ; von Tengg-Kobligk H; Ley-Zaporozhan J; Dillmann R; Kauczor HU; Unterhinninghofen R; Ley S
Cardiovasc Diagn Ther; 2014 Apr; 4(2):97-103. PubMed ID: 24834408
[TBL] [Abstract][Full Text] [Related]
2. Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation: comparison with young healthy volunteers.
Rengier F; Delles M; Eichhorn J; Azad YJ; von Tengg-Kobligk H; Ley-Zaporozhan J; Dillmann R; Kauczor HU; Unterhinninghofen R; Ley S
Int J Cardiovasc Imaging; 2015 Apr; 31(4):823-30. PubMed ID: 25645544
[TBL] [Abstract][Full Text] [Related]
3. [4D FLOW Magnetic Resonance Imaging in the Study of Blood Flow in Patients With Aortic Coarctation in the Long-Term After Surgery].
Yurpolskaya LA; Shlyappo MA; Makarenko VN; Svobodov AA; Levchenko EG; Makarenko MV; Poromov AA
Kardiologiia; 2020 Sep; 60(8):54-64. PubMed ID: 33155959
[TBL] [Abstract][Full Text] [Related]
4. Clinical evaluation of aortic coarctation with 4D flow MR imaging.
Hope MD; Meadows AK; Hope TA; Ordovas KG; Saloner D; Reddy GP; Alley MT; Higgins CB
J Magn Reson Imaging; 2010 Mar; 31(3):711-8. PubMed ID: 20187217
[TBL] [Abstract][Full Text] [Related]
5. Aortic hemodynamics in patients with and without repair of aortic coarctation: in vivo analysis by 4D flow-sensitive magnetic resonance imaging.
Frydrychowicz A; Markl M; Hirtler D; Harloff A; Schlensak C; Geiger J; Stiller B; Arnold R
Invest Radiol; 2011 May; 46(5):317-25. PubMed ID: 21285892
[TBL] [Abstract][Full Text] [Related]
6. Magnetic resonance volume flow and jet velocity mapping in aortic coarctation.
Mohiaddin RH; Kilner PJ; Rees S; Longmore DB
J Am Coll Cardiol; 1993 Nov; 22(5):1515-21. PubMed ID: 8227813
[TBL] [Abstract][Full Text] [Related]
7. Abnormalities of aortic arch shape, central aortic flow dynamics, and distensibility predispose to hypertension after successful repair of aortic coarctation.
Donazzan L; Crepaz R; Stuefer J; Stellin G
World J Pediatr Congenit Heart Surg; 2014 Oct; 5(4):546-53. PubMed ID: 25324252
[TBL] [Abstract][Full Text] [Related]
8. Time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI) reveals altered blood flow patterns in the ascending aorta of patients with valve-sparing aortic root replacement.
Oechtering TH; Sieren MM; Hunold P; Hennemuth A; Huellebrand M; Scharfschwerdt M; Richardt D; Sievers HH; Barkhausen J; Frydrychowicz A
J Thorac Cardiovasc Surg; 2020 Mar; 159(3):798-810.e1. PubMed ID: 31078313
[TBL] [Abstract][Full Text] [Related]
9. In vivo noninvasive 4D pressure difference mapping in the human aorta: phantom comparison and application in healthy volunteers and patients.
Bock J; Frydrychowicz A; Lorenz R; Hirtler D; Barker AJ; Johnson KM; Arnold R; Burkhardt H; Hennig J; Markl M
Magn Reson Med; 2011 Oct; 66(4):1079-88. PubMed ID: 21437978
[TBL] [Abstract][Full Text] [Related]
10. Analysis of aortic pressure fields from 4D flow MRI in healthy volunteers: Associations with age and left ventricular remodeling.
Bouaou K; Bargiotas I; Dietenbeck T; Bollache E; Soulat G; Craiem D; Houriez-Gombaud-Saintonge S; De Cesare A; Gencer U; Giron A; Redheuil A; Messas E; Lucor D; Mousseaux E; Kachenoura N
J Magn Reson Imaging; 2019 Sep; 50(3):982-993. PubMed ID: 30714258
[TBL] [Abstract][Full Text] [Related]
11. Imaging-Based 4D Aortic Pressure Mapping in Marfan Syndrome Patients: A Matched Case-Control Study.
Leidenberger T; Gordon Y; Farag M; Delles M; Fava Sanches A; Fink MA; Kallenbach K; Kauczor HU; Rengier F
Ann Thorac Surg; 2020 May; 109(5):1434-1440. PubMed ID: 31568745
[TBL] [Abstract][Full Text] [Related]
12. Patient-specific requirements and clinical validation of MRI-based pressure mapping: A two-center study in patients with aortic coarctation.
Goubergrits L; Hellmeier F; Neumann D; Mihalef V; Gulsun MA; Chinali M; Secinaro A; Runte K; Schubert S; Berger F; Kuehne T; Hennemuth A; Kelm M
J Magn Reson Imaging; 2019 Jan; 49(1):81-89. PubMed ID: 30390353
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of 4D flow MRI-based non-invasive pressure assessment in aortic coarctations.
Saitta S; Pirola S; Piatti F; Votta E; Lucherini F; Pluchinotta F; Carminati M; Lombardi M; Geppert C; Cuomo F; Figueroa CA; Xu XY; Redaelli A
J Biomech; 2019 Sep; 94():13-21. PubMed ID: 31326119
[TBL] [Abstract][Full Text] [Related]
14. Time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI) analysis of hemodynamics in valve-sparing aortic root repair with an anatomically shaped sinus prosthesis.
Oechtering TH; Hons CF; Sieren M; Hunold P; Hennemuth A; Huellebrand M; Drexl J; Scharfschwerdt M; Richardt D; Sievers HH; Barkhausen J; Frydrychowicz A
J Thorac Cardiovasc Surg; 2016 Aug; 152(2):418-427.e1. PubMed ID: 27423836
[TBL] [Abstract][Full Text] [Related]
15. Computational fluid dynamics simulations as a complementary study for transcatheter endovascular stent implantation for re-coarctation of the aorta associated with minimal pressure drop: an aneurysmal ductal ampulla with aortic isthmus narrowing.
Guillot M; Ascuitto R; Ross-Ascuitto N; Mallula K; Siwik E
Cardiol Young; 2019 Jun; 29(6):768-776. PubMed ID: 31198121
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of aortic coarctation after surgical repair: role of magnetic resonance imaging and Doppler ultrasound.
Mühler EG; Neuerburg JM; Rüben A; Grabitz RG; Günther RW; Messmer BJ; von Bernuth G
Br Heart J; 1993 Sep; 70(3):285-90. PubMed ID: 8398504
[TBL] [Abstract][Full Text] [Related]
17. Quantitative Analysis of Vortical Blood Flow in the Thoracic Aorta Using 4D Phase Contrast MRI.
von Spiczak J; Crelier G; Giese D; Kozerke S; Maintz D; Bunck AC
PLoS One; 2015; 10(9):e0139025. PubMed ID: 26418327
[TBL] [Abstract][Full Text] [Related]
18. Pressure fields by flow-sensitive, 4D, velocity-encoded CMR in patients with aortic coarctation.
Riesenkampff E; Fernandes JF; Meier S; Goubergrits L; Kropf S; Schubert S; Berger F; Hennemuth A; Kuehne T
JACC Cardiovasc Imaging; 2014 Sep; 7(9):920-6. PubMed ID: 25212797
[TBL] [Abstract][Full Text] [Related]
19. Repair of coarctation of the aorta in neonates and young infants.
Van Son JA; Falk V; Schneider P; Smedts F; Mohr FW
J Card Surg; 1997; 12(3):139-46. PubMed ID: 9395942
[TBL] [Abstract][Full Text] [Related]
20. [The utility of various Doppler parameters at rest and during exercise for the diagnosis of residual stenosis after operation for aortic coarctation. A doppler-nuclear magnetic resonance comparison].
Crepaz R; Knoll P; Paulmichl R; Pitscheider W
G Ital Cardiol; 1998 Apr; 28(4):369-76. PubMed ID: 9616851
[TBL] [Abstract][Full Text] [Related]