These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

429 related articles for article (PubMed ID: 24847017)

  • 1. Biolimus-eluting stents with biodegradable polymer versus bare-metal stents in acute myocardial infarction: two-year clinical results of the COMFORTABLE AMI trial.
    Räber L; Kelbæk H; Taniwaki M; Ostojic M; Heg D; Baumbach A; von Birgelen C; Roffi M; Tüller D; Engstrøm T; Moschovitis A; Pedrazzini G; Wenaweser P; Kornowski R; Weber K; Lüscher TF; Matter CM; Meier B; Jüni P; Windecker S;
    Circ Cardiovasc Interv; 2014 Jun; 7(3):355-64. PubMed ID: 24847017
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFORTABLE-AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) trials.
    Sabaté M; Räber L; Heg D; Brugaletta S; Kelbaek H; Cequier A; Ostojic M; Iñiguez A; Tüller D; Serra A; Baumbach A; von Birgelen C; Hernandez-Antolin R; Roffi M; Mainar V; Valgimigli M; Serruys PW; Jüni P; Windecker S
    JACC Cardiovasc Interv; 2014 Jan; 7(1):55-63. PubMed ID: 24332419
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction: the COMFORTABLE AMI randomized trial.
    Räber L; Kelbæk H; Ostojic M; Baumbach A; Heg D; Tüller D; von Birgelen C; Roffi M; Moschovitis A; Khattab AA; Wenaweser P; Bonvini R; Pedrazzini G; Kornowski R; Weber K; Trelle S; Lüscher TF; Taniwaki M; Matter CM; Meier B; Jüni P; Windecker S;
    JAMA; 2012 Aug; 308(8):777-87. PubMed ID: 22910755
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial.
    Serruys PW; Farooq V; Kalesan B; de Vries T; Buszman P; Linke A; Ischinger T; Klauss V; Eberli F; Wijns W; Morice MC; Di Mario C; Corti R; Antoni D; Sohn HY; Eerdmans P; Rademaker-Havinga T; van Es GA; Meier B; Jüni P; Windecker S
    JACC Cardiovasc Interv; 2013 Aug; 6(8):777-89. PubMed ID: 23968698
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Five-year clinical outcomes and intracoronary imaging findings of the COMFORTABLE AMI trial: randomized comparison of biodegradable polymer-based biolimus-eluting stents with bare-metal stents in patients with acute ST-segment elevation myocardial infarction.
    Räber L; Yamaji K; Kelbæk H; Engstrøm T; Baumbach A; Roffi M; von Birgelen C; Taniwaki M; Moschovitis A; Zaugg S; Ostojic M; Pedrazzini G; Karagiannis-Voules DA; Lüscher TF; Kornowski R; Tüller D; Vukcevic V; Heg D; Windecker S
    Eur Heart J; 2019 Jun; 40(24):1909-1919. PubMed ID: 30851032
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-Term outcome of drug-eluting stents compared with bare metal stents in ST-segment elevation myocardial infarction: results of the paclitaxel- or sirolimus-eluting stent versus bare metal stent in Primary Angioplasty (PASEO) Randomized Trial.
    Di Lorenzo E; Sauro R; Varricchio A; Carbone G; Cortese G; Capasso M; Lanzillo T; Manganelli F; Mariello C; Siano F; Pagliuca MR; Stanco G; Rosato G; De Luca G
    Circulation; 2009 Sep; 120(11):964-72. PubMed ID: 19720939
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design.
    Räber L; Kelbaek H; Ostoijc M; Baumbach A; Tüller D; von Birgelen C; Roffi M; Pedrazzini G; Kornowski R; Weber K; Heg D; Matter C; Lüscher T; Taniwaki M; Meier B; Jüni P; Windecker S
    EuroIntervention; 2012 Apr; 7(12):1435-43. PubMed ID: 22301368
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of biolimus A9-eluting (Nobori) and everolimus-eluting (Promus Element) stents in patients with de novo native long coronary artery lesions: a randomized Long Drug-Eluting Stent V trial.
    Lee JY; Park DW; Kim YH; Ahn JM; Kim WJ; Kang SJ; Lee SW; Lee CW; Park SW; Yun SC; Yang TH; Lee BK; Lee NH; Yang JY; Shin WY; Park HS; Kim KS; Hur SH; Lee SY; Park JS; Choi YS; Lee SU; Her SH; Park SJ
    Circ Cardiovasc Interv; 2014 Jun; 7(3):322-9. PubMed ID: 24823426
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent in patients with acute myocardial infarction.
    Lee HJ; Park TK; Song YB; Choi YJ; Yu CW; Yang JH; Hahn JY; Choi SH; Choi RK; Choi JH; Park JS; Kim JS; Kim TH; Jang HJ; Lee SH; Shim WH; Roh YM; Gwon HC
    Int J Cardiol; 2015 Mar; 183():190-7. PubMed ID: 25668147
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Final 3-Year Outcome of a Randomized Trial Comparing Second-Generation Drug-Eluting Stents Using Either Biodegradable Polymer or Durable Polymer: NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial.
    Natsuaki M; Kozuma K; Morimoto T; Kadota K; Muramatsu T; Nakagawa Y; Akasaka T; Igarashi K; Tanabe K; Morino Y; Ishikawa T; Nishikawa H; Awata M; Abe M; Okada H; Takatsu Y; Ogata N; Kimura K; Urasawa K; Tarutani Y; Shiode N; Kimura T
    Circ Cardiovasc Interv; 2015 Oct; 8(10):. PubMed ID: 26446596
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biolimus-eluting biodegradable polymer-coated stent versus bare metal stent in acute ST-elevation and non-ST elevation myocardial infarction: Justification for biodegradable polymer-coated stent in acute coronary syndrome (JANICE) registry.
    Chia PL; Earnest A; Lim J
    Acute Card Care; 2011 Mar; 13(1):43-7. PubMed ID: 21323412
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 5-year follow-up after primary percutaneous coronary intervention with a paclitaxel-eluting stent versus a bare-metal stent in acute ST-segment elevation myocardial infarction: a follow-up study of the PASSION (Paclitaxel-Eluting Versus Conventional Stent in Myocardial Infarction with ST-Segment Elevation) trial.
    Vink MA; Dirksen MT; Suttorp MJ; Tijssen JG; van Etten J; Patterson MS; Slagboom T; Kiemeneij F; Laarman GJ
    JACC Cardiovasc Interv; 2011 Jan; 4(1):24-9. PubMed ID: 21251625
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prediction of 1-year clinical outcomes using the SYNTAX score in patients with acute ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention: a substudy of the STRATEGY (Single High-Dose Bolus Tirofiban and Sirolimus-Eluting Stent Versus Abciximab and Bare-Metal Stent in Acute Myocardial Infarction) and MULTISTRATEGY (Multicenter Evaluation of Single High-Dose Bolus Tirofiban Versus Abciximab With Sirolimus-Eluting Stent or Bare-Metal Stent in Acute Myocardial Infarction Study) trials.
    Garg S; Sarno G; Serruys PW; Rodriguez AE; Bolognese L; Anselmi M; De Cesare N; Colangelo S; Moreno R; Gambetti S; Monti M; Bristot L; Bressers M; Garcia-Garcia HM; Parrinello G; Campo G; Valgimigli M;
    JACC Cardiovasc Interv; 2011 Jan; 4(1):66-75. PubMed ID: 21251631
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Long-term efficacy and safety of biodegradable-polymer biolimus-eluting stents: main results of the Basel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination II (BASKET-PROVE II), a randomized, controlled noninferiority 2-year outcome trial.
    Kaiser C; Galatius S; Jeger R; Gilgen N; Skov Jensen J; Naber C; Alber H; Wanitschek M; Eberli F; Kurz DJ; Pedrazzini G; Moccetti T; Rickli H; Weilenmann D; Vuillomenet A; Steiner M; Von Felten S; Vogt DR; Wadt Hansen K; Rickenbacher P; Conen D; Müller C; Buser P; Hoffmann A; Pfisterer M;
    Circulation; 2015 Jan; 131(1):74-81. PubMed ID: 25411159
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Paclitaxel-eluting stents versus bare-metal stents in acute myocardial infarction.
    Stone GW; Lansky AJ; Pocock SJ; Gersh BJ; Dangas G; Wong SC; Witzenbichler B; Guagliumi G; Peruga JZ; Brodie BR; Dudek D; Möckel M; Ochala A; Kellock A; Parise H; Mehran R;
    N Engl J Med; 2009 May; 360(19):1946-59. PubMed ID: 19420364
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical outcomes with bioabsorbable polymer- versus durable polymer-based drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.
    Palmerini T; Biondi-Zoccai G; Della Riva D; Mariani A; Sabaté M; Smits PC; Kaiser C; D'Ascenzo F; Frati G; Mancone M; Genereux P; Stone GW
    J Am Coll Cardiol; 2014 Feb; 63(4):299-307. PubMed ID: 24211507
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The EXAMINATION trial (Everolimus-Eluting Stents Versus Bare-Metal Stents in ST-Segment Elevation Myocardial Infarction): 2-year results from a multicenter randomized controlled trial.
    Sabaté M; Brugaletta S; Cequier A; Iñiguez A; Serra A; Hernádez-Antolín R; Mainar V; Valgimigli M; Tespili M; den Heijer P; Bethencourt A; Vázquez N; Backx B; Serruys PW
    JACC Cardiovasc Interv; 2014 Jan; 7(1):64-71. PubMed ID: 24332423
    [TBL] [Abstract][Full Text] [Related]  

  • 18. First results of the DEB-AMI (drug eluting balloon in acute ST-segment elevation myocardial infarction) trial: a multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in primary percutaneous coronary intervention with 6-month angiographic, intravascular, functional, and clinical outcomes.
    Belkacemi A; Agostoni P; Nathoe HM; Voskuil M; Shao C; Van Belle E; Wildbergh T; Politi L; Doevendans PA; Sangiorgi GM; Stella PR
    J Am Coll Cardiol; 2012 Jun; 59(25):2327-37. PubMed ID: 22503057
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention: The SORT OUT VII Trial.
    Jensen LO; Thayssen P; Maeng M; Ravkilde J; Krusell LR; Raungaard B; Junker A; Terkelsen CJ; Veien KT; Villadsen AB; Kaltoft A; Tilsted HH; Hansen KN; Aaroe J; Kristensen SD; Hansen HS; Jensen SE; Madsen M; Bøtker HE; Berencsi K; Lassen JF; Christiansen EH
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27412869
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study.
    Parsa E; Saroukhani S; Majlessi F; Poorhosseini H; Lofti-Tokaldany M; Jalali A; Salarifar M; Nematipour E; Alidoosti M; Aghajani H; Amirzadegan A; Kassaian SE
    Tex Heart Inst J; 2016 Apr; 43(2):126-30. PubMed ID: 27127426
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.