These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 24847039)

  • 1. Is it feasible to diagnose catheter-related candidemia without catheter withdrawal?
    Fernández-Cruz A; Martín-Rabadán P; Suárez-Salas M; Rojas-Wettig L; Pérez MJ; Guinea J; Guembe M; Peláez T; Sánchez-Carrillo C; Bouza E;
    Med Mycol; 2014 Jul; 52(5):491-7. PubMed ID: 24847039
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In situ diagnostic methods for catheter related bloodstream infection in burns patients: A pilot study.
    Evans O; Gowardman J; Rabbolini D; McGrail M; Rickard CM
    Burns; 2016 Mar; 42(2):434-40. PubMed ID: 26778703
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Assessment of diagnostic methods for the catheter-related bloodstream infections in intensive care units].
    Ataman Hatipoğlu C; Ipekkan K; Oral B; Onde U; Bulut C; Demiröz AP
    Mikrobiyol Bul; 2011 Jan; 45(1):75-85. PubMed ID: 21341162
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Differential time to positivity of blood cultures: a valid method for diagnosing catheter-related bloodstream infections in the intensive care unit.
    García X; Sabatier C; Ferrer R; Fontanals D; Duarte M; Colomina M; Artigas A; Vallés J
    Med Intensiva; 2012 Apr; 36(3):169-76. PubMed ID: 22172517
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparative assessment of two conservative methods for the diagnosis of catheter-related infection in critically ill patients.
    Gowardman JR; Jeffries P; Lassig-Smith M; Stuart J; Jarrett P; Deans R; McGrail M; George NM; Nimmo GR; Rickard CM
    Intensive Care Med; 2013 Jan; 39(1):109-16. PubMed ID: 23011530
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diagnostic usefulness of differential time to positivity for catheter-related candidemia.
    Park KH; Lee MS; Lee SO; Choi SH; Sung H; Kim MN; Kim YS; Woo JH; Kim SH
    J Clin Microbiol; 2014 Jul; 52(7):2566-72. PubMed ID: 24829236
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Differential time to positivity: vascular catheter drawn cultures for the determination of catheter-related bloodstream infection.
    Al-Juaid A; Walkty A; Embil J; Crockett M; Karlowsky J
    Scand J Infect Dis; 2012 Oct; 44(10):721-5. PubMed ID: 22681307
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A randomized and prospective study of 3 procedures for the diagnosis of catheter-related bloodstream infection without catheter withdrawal.
    Bouza E; Alvarado N; Alcalá L; Pérez MJ; Rincón C; Muñoz P
    Clin Infect Dis; 2007 Mar; 44(6):820-6. PubMed ID: 17304454
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Blood culture differential time to positivity enables safe catheter retention in suspected catheter-related bloodstream infection: a randomized controlled trial.
    Sabatier C; García X; Ferrer R; Duarte M; Colomina M; Alcaráz D; Fontanals D; Vallés J
    Med Intensiva; 2015 Apr; 39(3):135-41. PubMed ID: 24661917
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Can microbiologists help to assess catheter involvement in candidaemic patients before removal?
    Bouza E; Alcalá L; Muñoz P; Martín-Rabadán P; Guembe M; Rodríguez-Créixems M;
    Clin Microbiol Infect; 2013 Feb; 19(2):E129-35. PubMed ID: 23231412
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Differential time to positivity is not predictive for central line-related Staphylococcus aureus bloodstream infection in routine clinical care.
    Kaasch AJ; Rieg S; Hellmich M; Kern WV; Seifert H
    J Infect; 2014 Jan; 68(1):58-61. PubMed ID: 23954613
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diagnosis of catheter-related bloodstream infection in neonates: a study on the value of differential time to positivity of paired blood cultures.
    Guerti K; Ieven M; Mahieu L
    Pediatr Crit Care Med; 2007 Sep; 8(5):470-5. PubMed ID: 17693911
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is catheter-related candidemia a polyclonal infection?
    Escribano P; Guinea J; Marcos-Zambrano LJ; Martín-Rabadán P; Fernández-Cruz A; Sánchez-Carrillo C; Muñoz P; Bouza E
    Med Mycol; 2014 May; 52(4):411-6. PubMed ID: 24625673
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the Alfred™ turbidity monitoring system (Alifax®) following sonication in the diagnosis of central venous catheter colonization.
    Alonso B; Latorre MC; Cruces R; Ampuero D; Haces L; Martín-Rabadán P; Sánchez-Carrillo C; Rodríguez B; Bouza E; Muñoz P; Guembe M
    Eur J Clin Microbiol Infect Dis; 2019 Sep; 38(9):1737-1742. PubMed ID: 31209648
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Predictive value of superficial cultures to anticipate tunneled hemodialysis catheter-related bloodstream infection.
    Bouza E; Rojas L; Guembe M; Marín M; Anaya F; Luño J; López JM; Muñoz P;
    Diagn Microbiol Infect Dis; 2014 Mar; 78(3):316-9. PubMed ID: 24428979
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evolution and aetiological shift of catheter-related bloodstream infection in a whole institution: the microbiology department may act as a watchtower.
    Rodríguez-Créixems M; Muñoz P; Martín-Rabadán P; Cercenado E; Guembe M; Bouza E
    Clin Microbiol Infect; 2013 Sep; 19(9):845-51. PubMed ID: 23565810
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diagnostic usefulness of differential time to positivity in neutropenic cancer patients with suspected catheter-related candidemia.
    Jo KM; Choi S; Jung KH; Park JW; Yun JH; Kim MJ; Chong YP; Lee SO; Choi SH; Kim YS; Woo JH; Lee JH; Lee JH; Lee KH; Kim SH
    Med Mycol; 2020 Jan; 58(1):137-140. PubMed ID: 30927433
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Role of the central venous catheter in bloodstream infections caused by coagulase-negative staphylococci in very preterm neonates.
    Lepainteur M; Desroches M; Bourrel AS; Aberrane S; Fihman V; L'Hériteau F; Razafimahefa H; Derouin V; Doucet-Populaire F; Decousser JW
    Pediatr Infect Dis J; 2013 Jun; 32(6):622-8. PubMed ID: 23429561
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High rate of Candida deep-seated infection in patients under chronic hemodialysis with extended central venous catheter use.
    Ourives AP; Gonçalves SS; Siqueira RA; Souza AC; Canziani ME; Manfredi SR; Correa L; Colombo AL
    Rev Iberoam Micol; 2016; 33(2):100-3. PubMed ID: 26874585
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Multilocus sequence typing of Candida albicans bloodstream isolates in an intensive care unit].
    Xiao YL; Xie Y; Kang M; Deng Y; He C; Guo L; Chen ZX; Chen HL; Fan H
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2012 Sep; 43(5):697-701. PubMed ID: 23230742
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.