406 related articles for article (PubMed ID: 24847132)
1. Transcatheter aortic valve replacement performed via left ventricular assist device inflow cannula.
Vavalle JP; Kiefer TL; Milano CA; Harrison JK; Hughes GC
Circ Heart Fail; 2014 May; 7(3):544-6. PubMed ID: 24847132
[No Abstract] [Full Text] [Related]
2. TAVI for pure aortic valve insufficiency in a patient with a left ventricular assist device.
D'Ancona G; Pasic M; Buz S; Drews T; Dreysse S; Hetzer R; Unbehaun A
Ann Thorac Surg; 2012 Apr; 93(4):e89-91. PubMed ID: 22450111
[TBL] [Abstract][Full Text] [Related]
3. Direct aortic transcatheter aortic valve implantation for pure aortic valve regurgitation after implantation of a left ventricular assist device.
Krause R; Metz D; Bushnaq H
J Thorac Cardiovasc Surg; 2014 Apr; 147(4):e38-41. PubMed ID: 24495901
[No Abstract] [Full Text] [Related]
4. Case 7-2013: Percutaneous closure of the aortic valve for severe aortic insufficiency due to a left ventricular assist device.
Feider AJ; Chaney MA; Cowger JA; Thomas SS; Jorde UP
J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1407-13. PubMed ID: 23994175
[No Abstract] [Full Text] [Related]
5. Surgical correction of aortic valve insufficiency after left ventricular assist device implantation.
Atkins BZ; Hashmi ZA; Ganapathi AM; Harrison JK; Hughes GC; Rogers JG; Milano CA
J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1247-52. PubMed ID: 23870154
[TBL] [Abstract][Full Text] [Related]
6. Surgical closure of left ventricular outflow tract after left ventricular assist device implantation in patients with aortic valve pathology.
Cohn WE; Demirozu ZT; Frazier OH
J Heart Lung Transplant; 2011 Jan; 30(1):59-63. PubMed ID: 20884246
[TBL] [Abstract][Full Text] [Related]
7. Concomitant transcatheter aortic valve and left ventricular assist device implantation.
Baum C; Seiffert M; Treede H; Reichenspurner H; Deuse T
ASAIO J; 2013; 59(1):90-2. PubMed ID: 23271392
[TBL] [Abstract][Full Text] [Related]
8. Delayed left ventricle-to-right atrial fistula following aortic valve replacement.
Anderson CA; Rodriguez E; Kypson AP
J Heart Valve Dis; 2012 May; 21(3):364-5. PubMed ID: 22808839
[TBL] [Abstract][Full Text] [Related]
9. Transcatheter aortic valve implantation in patients with a left ventricular assist device: a word of caution.
Ali J; Catarino P; Abu-Omar Y
Eur J Cardiothorac Surg; 2020 Dec; 58(6):1309-1310. PubMed ID: 32766699
[TBL] [Abstract][Full Text] [Related]
10. Transfemoral transcatheter aortic valve replacement with a self-expanding valve for severe aortic regurgitation in a patient with left ventricular assist device.
Rene AG; Desai N; Wald J; Rame JE; Frogel JK; Anwaruddin S
J Card Surg; 2017 Nov; 32(11):741-745. PubMed ID: 29178215
[TBL] [Abstract][Full Text] [Related]
11. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.
McKellar SH; Deo S; Daly RC; Durham LA; Joyce LD; Stulak JM; Park SJ
J Thorac Cardiovasc Surg; 2014 Jan; 147(1):344-8. PubMed ID: 23246052
[TBL] [Abstract][Full Text] [Related]
12. Management of aortic insufficiency with continuous flow left ventricular assist devices: bioprosthetic valve replacement.
Feldman CM; Silver MA; Sobieski MA; Slaughter MS
J Heart Lung Transplant; 2006 Dec; 25(12):1410-2. PubMed ID: 17178333
[TBL] [Abstract][Full Text] [Related]
13. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries.
Ihlberg L; Nissen H; Nielsen NE; Rück A; Busund R; Klaarborg KE; Soendergaard L; Harnek J; Miettinen H; Eskola M; Wahba A; Laine M
J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1047-54; discussion 1054. PubMed ID: 23998786
[TBL] [Abstract][Full Text] [Related]
14. Transcatheter aortic valve replacement for isolated aortic valve insufficiency: experience with the Engager valve.
Kiefer P; Seeburger J; Mohr FW; Holzhey DM
J Thorac Cardiovasc Surg; 2014 Apr; 147(4):e37-8. PubMed ID: 24433953
[No Abstract] [Full Text] [Related]
15. Transcatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report.
Lotfi S; Becker M; Moza A; Autschbach R; Marx N; Schröder J
J Med Case Rep; 2017 Sep; 11(1):256. PubMed ID: 28888221
[TBL] [Abstract][Full Text] [Related]
16. Reversal of ventricular dilatation in aortic regurgitation after valve replacement and cardiac support implant surgery using the CorCap cardiac support device.
Franco-Cereceda A; Lockowandt U; Liska J; Olsson A
Ann Thorac Surg; 2005 Jul; 80(1):315-6. PubMed ID: 15975391
[TBL] [Abstract][Full Text] [Related]
17. Successful percutaneous transcatheter aortic valve replacement in multi-organ failure due to aortic bioprosthesis regurgitation in a patient with continuous-flow LVAD.
Khan S; Koerner MM; Pae W; Stephenson ER; Weber H; Brehm C; El-Banayosy A
J Heart Lung Transplant; 2013 Jun; 32(6):659-63. PubMed ID: 23701856
[No Abstract] [Full Text] [Related]
18. Aortic regurgitation after transcatheter aortic valve implantation.
Costopoulos C; Naganuma T; Latib A; Colombo A
Expert Rev Cardiovasc Ther; 2013 Sep; 11(9):1089-92. PubMed ID: 23944936
[No Abstract] [Full Text] [Related]
19. Percutaneous SAPIEN S3 Transcatheter Valve Implantation for Post-Left Ventricular Assist Device Aortic Regurgitation.
Kornberger A; Beiras-Fernandez A; Fichtlscherer S; Assmus B; Moritz A; Stock UA
Ann Thorac Surg; 2015 Oct; 100(4):e67-9. PubMed ID: 26434481
[TBL] [Abstract][Full Text] [Related]
20. Expanding role for transcatheter aortic valve replacement: successful transfemoral implantation of a Medtronic CoreValve for severe aortic regurgitation.
Yeow WL; Roberts-Thomson P; Shetty S; Yong G
Heart Lung Circ; 2012 Nov; 21(11):754-8. PubMed ID: 22542043
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]