These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 24853626)

  • 1. Mini gamma cameras for intra-operative nuclear tomographic reconstruction.
    Matthies P; Gardiazabal J; Okur A; Vogel J; Lasser T; Navab N
    Med Image Anal; 2014 Dec; 18(8):1329-36. PubMed ID: 24853626
    [TBL] [Abstract][Full Text] [Related]  

  • 2. First use of mini gamma cameras for intra-operative robotic SPECT reconstruction.
    Matthies P; Sharma K; Okur A; Gardiazabal J; Vogel J; Lasserl T; Navab N
    Med Image Comput Comput Assist Interv; 2013; 16(Pt 1):163-70. PubMed ID: 24505662
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Trajectory optimization for intra-operative nuclear tomographic imaging.
    Vogel J; Lasser T; Gardiazabal J; Navab N
    Med Image Anal; 2013 Oct; 17(7):723-31. PubMed ID: 23706624
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Flexible mini gamma camera reconstructions of extended sources using step and shoot and list mode.
    Gardiazabal J; Matthies P; Vogel J; Frisch B; Navab N; Ziegler S; Lasser T
    Med Phys; 2016 Dec; 43(12):6418. PubMed ID: 27908169
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Towards intra-operative 3D nuclear imaging: reconstruction of 3D radioactive distributions using tracked gamma probes.
    Wendler T; Hartl A; Lasser T; Traub J; Daghighian F; Ziegler SI; Navab N
    Med Image Comput Comput Assist Interv; 2007; 10(Pt 2):909-17. PubMed ID: 18044655
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging.
    Zeniya T; Watabe H; Aoi T; Kim KM; Teramoto N; Takeno T; Ohta Y; Hayashi T; Mashino H; Ota T; Yamamoto S; Iida H
    Ann Nucl Med; 2006 Jul; 20(6):409-16. PubMed ID: 16922469
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
    Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
    J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A newly developed intra-operative gamma camera: performance characteristics in a laboratory phantom study.
    Kopelman D; Blevis I; Iosilevsky G; Reznik A; Chaikov A; Weiner N; Israel O; Hashmonai M
    Eur J Nucl Med Mol Imaging; 2005 Oct; 32(10):1217-24. PubMed ID: 15909193
    [TBL] [Abstract][Full Text] [Related]  

  • 9. CdZnTe strip detector SPECT imaging with a slit collimator.
    Zheng GL; Gagnon D
    Phys Med Biol; 2004 Jun; 49(11):2257-71. PubMed ID: 15248576
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fast 3D iterative image reconstruction for SPECT with rotating slat collimators.
    Holen RV; Vandenberghe S; Staelens S; De Beenhouwer J; Lemahieu I
    Phys Med Biol; 2009 Feb; 54(3):715-29. PubMed ID: 19131666
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera.
    Gambhir SS; Berman DS; Ziffer J; Nagler M; Sandler M; Patton J; Hutton B; Sharir T; Haim SB; Haim SB
    J Nucl Med; 2009 Apr; 50(4):635-43. PubMed ID: 19339672
    [TBL] [Abstract][Full Text] [Related]  

  • 12. First results from the high-resolution mouseSPECT annular scintillation camera.
    Goertzen AL; Jones DW; Seidel J; Li K; Green MV
    IEEE Trans Med Imaging; 2005 Jul; 24(7):863-7. PubMed ID: 16011315
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector.
    Brzymialkiewicz CN; Tornai MP; McKinley RL; Bowsher JE
    IEEE Trans Med Imaging; 2005 Jul; 24(7):868-77. PubMed ID: 16011316
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Molecular imaging of small animals with a triple-head SPECT system using pinhole collimation.
    Metzler SD; Jaszczak RJ; Patil NH; Vemulapalli S; Akabani G; Chin BB
    IEEE Trans Med Imaging; 2005 Jul; 24(7):853-62. PubMed ID: 16011314
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A CCD based approach to collimated photon counting imaging for micro-SPECT/CT.
    Eaker DR; Dzyubak B; Jorgensen SM; Ritman EL
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():990-2. PubMed ID: 19963985
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A pinhole gamma camera with optical depth-of-interaction elimination.
    Korevaar MA; Heemskerk JW; Beekman FJ
    Phys Med Biol; 2009 Jul; 54(13):N267-72. PubMed ID: 19521006
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Imaging characteristics of a 3-dimensional GSO whole-body PET camera.
    Surti S; Karp JS
    J Nucl Med; 2004 Jun; 45(6):1040-9. PubMed ID: 15181139
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Extrinsic Versus Intrinsic Uniformity Correction for γ-cameras.
    Bolstad R; Brown J; Grantham V
    J Nucl Med Technol; 2011 Sep; 39(3):208-12. PubMed ID: 21795372
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intrinsic uniformity requirements for pinhole SPECT.
    Seret A; Bleeser F
    J Nucl Med Technol; 2006 Mar; 34(1):43-7. PubMed ID: 16517968
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A flexible multicamera visual-tracking system for detecting and correcting motion-induced artifacts in cardiac SPECT slices.
    McNamara JE; Pretorius PH; Johnson K; Mukherjee JM; Dey J; Gennert MA; King MA
    Med Phys; 2009 May; 36(5):1913-23. PubMed ID: 19544811
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.