These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

430 related articles for article (PubMed ID: 24855843)

  • 1. Clinical validation of pulse contour and pulse wave transit time-based continuous cardiac output analyses in Thai patients undergoing cardiac surgery.
    Wacharasint P; Kunakorn P; Pankongsap P; Preechanukul R
    J Med Assoc Thai; 2014 Jan; 97 Suppl 1():S55-60. PubMed ID: 24855843
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output.
    Yamada T; Tsutsui M; Sugo Y; Sato T; Akazawa T; Sato N; Yamashita K; Ishihara H; Takeda J
    Anesth Analg; 2012 Jul; 115(1):82-7. PubMed ID: 22467885
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method.
    Thonnerieux M; Alexander B; Binet C; Obadia JF; Bastien O; Desebbe O
    Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cardiac Output Measurements Based on the Pulse Wave Transit Time and Thoracic Impedance Exhibit Limited Agreement With Thermodilution Method During Orthotopic Liver Transplantation.
    Magliocca A; Rezoagli E; Anderson TA; Burns SM; Ichinose F; Chitilian HV
    Anesth Analg; 2018 Jan; 126(1):85-92. PubMed ID: 28598912
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Estimated continuous cardiac output based on pulse wave transit time in off-pump coronary artery bypass grafting: a comparison with transpulmonary thermodilution.
    Smetkin AA; Hussain A; Fot EV; Zakharov VI; Izotova NN; Yudina AS; Dityateva ZA; Gromova YV; Kuzkov VV; Bjertnæs LJ; Kirov MY
    J Clin Monit Comput; 2017 Apr; 31(2):361-370. PubMed ID: 26951494
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration.
    Manecke GR; Auger WR
    J Cardiothorac Vasc Anesth; 2007 Feb; 21(1):3-7. PubMed ID: 17289472
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of the ability of two continuous cardiac output monitors to measure trends in cardiac output: estimated continuous cardiac output measured by modified pulse wave transit time and an arterial pulse contour-based cardiac output device.
    Terada T; Oiwa A; Maemura Y; Robert S; Kessoku S; Ochiai R
    J Clin Monit Comput; 2016 Oct; 30(5):621-7. PubMed ID: 26370094
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of noninvasive estimated continuous cardiac output (esCCO) compared to thermodilution cardiac output: a pilot study in cardiac patients.
    Ball TR; Tricinella AP; Kimbrough BA; Luna S; Gloyna DF; Villamaria FJ; Culp WC
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1128-32. PubMed ID: 23992653
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions.
    Della Rocca G; Costa MG; Chiarandini P; Bertossi G; Lugano M; Pompei L; Coccia C; Sainz-Barriga M; Pietropaoli P
    J Cardiothorac Vasc Anesth; 2008 Oct; 22(5):681-7. PubMed ID: 18922423
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison between continuous non-invasive estimated cardiac output by pulse wave transit time and thermodilution method.
    Sinha AC; Singh PM; Grewal N; Aman M; Dubowitz G
    Ann Card Anaesth; 2014; 17(4):273-7. PubMed ID: 25281622
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform.
    Lorsomradee S; Lorsomradee S; Cromheecke S; De Hert SG
    J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):636-43. PubMed ID: 17905266
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac output and stroke volume variation measured by the pulse wave transit time method: a comparison with an arterial pressure-based cardiac output system.
    Suzuki T; Suzuki Y; Okuda J; Minoshima R; Misonoo Y; Ueda T; Kato J; Nagata H; Yamada T; Morisaki H
    J Clin Monit Comput; 2019 Jun; 33(3):385-392. PubMed ID: 29948667
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial.
    McGee WT; Horswell JL; Calderon J; Janvier G; Van Severen T; Van den Berghe G; Kozikowski L
    Crit Care; 2007; 11(5):R105. PubMed ID: 17880692
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pulse wave transit time measurements of cardiac output in patients undergoing partial hepatectomy: a comparison of the esCCO system with thermodilution.
    Tsutsui M; Araki Y; Masui K; Kazama T; Sugo Y; Archer TL; Manecke GR
    Anesth Analg; 2013 Dec; 117(6):1307-12. PubMed ID: 24257379
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage.
    Junttila EK; Koskenkari JK; Ohtonen PP; Ala-Kokko TI
    Br J Anaesth; 2011 Oct; 107(4):581-6. PubMed ID: 21693470
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery.
    Lu JK; Zhu C; Jing H; Wang YJ; Qing EM
    Chin Med J (Engl); 2012 Jun; 125(12):2099-103. PubMed ID: 22884136
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.
    Missant C; Rex S; Wouters PF
    Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of a new arterial pulse contour-based cardiac output device.
    de Waal EE; Kalkman CJ; Rex S; Buhre WF
    Crit Care Med; 2007 Aug; 35(8):1904-9. PubMed ID: 17581493
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy of Estimated Continuous Cardiac Output Monitoring (esCCO) Using Pulse Wave Transit Time (PWTT) Compared to Arterial Pressure-based CO (APCO) Measurement during Major Surgeries.
    Joshi M; Rathod R; Bhosale SJ; Kulkarni AP
    Indian J Crit Care Med; 2022; 26(4):496-500. PubMed ID: 35656042
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the Pulse Wave Transit Time Method and an Arterial Pressure-Based Cardiac Output System for Measuring Cardiac Output Trends During Laparotomy Without Postural Change.
    Terada T; Kessoku S; Suzuki A; Kurosawa A; Nakagomi S; Oiwa A; Arai M; Sakamoto N; Idemitsu W; Ochiai R
    Asian J Anesthesiol; 2019 Sep; 57(3):85-92. PubMed ID: 31722470
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.