  • 1. Clinical validation of pulse contour and pulse wave transit time-based continuous cardiac output analyses in Thai patients undergoing cardiac surgery.
    Wacharasint P; Kunakorn P; Pankongsap P; Preechanukul R
    J Med Assoc Thai; 2014 Jan; 97 Suppl 1():S55-60. PubMed ID: 24855843
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output.
    Yamada T; Tsutsui M; Sugo Y; Sato T; Akazawa T; Sato N; Yamashita K; Ishihara H; Takeda J
    Anesth Analg; 2012 Jul; 115(1):82-7. PubMed ID: 22467885
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method.
    Thonnerieux M; Alexander B; Binet C; Obadia JF; Bastien O; Desebbe O
    Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cardiac Output Measurements Based on the Pulse Wave Transit Time and Thoracic Impedance Exhibit Limited Agreement With Thermodilution Method During Orthotopic Liver Transplantation.
    Magliocca A; Rezoagli E; Anderson TA; Burns SM; Ichinose F; Chitilian HV
    Anesth Analg; 2018 Jan; 126(1):85-92. PubMed ID: 28598912
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Estimated continuous cardiac output based on pulse wave transit time in off-pump coronary artery bypass grafting: a comparison with transpulmonary thermodilution.
    Smetkin AA; Hussain A; Fot EV; Zakharov VI; Izotova NN; Yudina AS; Dityateva ZA; Gromova YV; Kuzkov VV; Bjertnæs LJ; Kirov MY
    J Clin Monit Comput; 2017 Apr; 31(2):361-370. PubMed ID: 26951494
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration.
    Manecke GR; Auger WR
    J Cardiothorac Vasc Anesth; 2007 Feb; 21(1):3-7. PubMed ID: 17289472
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of the ability of two continuous cardiac output monitors to measure trends in cardiac output: estimated continuous cardiac output measured by modified pulse wave transit time and an arterial pulse contour-based cardiac output device.
    Terada T; Oiwa A; Maemura Y; Robert S; Kessoku S; Ochiai R
    J Clin Monit Comput; 2016 Oct; 30(5):621-7. PubMed ID: 26370094
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of noninvasive estimated continuous cardiac output (esCCO) compared to thermodilution cardiac output: a pilot study in cardiac patients.
    Ball TR; Tricinella AP; Kimbrough BA; Luna S; Gloyna DF; Villamaria FJ; Culp WC
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1128-32. PubMed ID: 23992653
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions.
    Della Rocca G; Costa MG; Chiarandini P; Bertossi G; Lugano M; Pompei L; Coccia C; Sainz-Barriga M; Pietropaoli P
    J Cardiothorac Vasc Anesth; 2008 Oct; 22(5):681-7. PubMed ID: 18922423
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison between continuous non-invasive estimated cardiac output by pulse wave transit time and thermodilution method.
    Sinha AC; Singh PM; Grewal N; Aman M; Dubowitz G
    Ann Card Anaesth; 2014; 17(4):273-7. PubMed ID: 25281622
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform.
    Lorsomradee S; Lorsomradee S; Cromheecke S; De Hert SG
    J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):636-43. PubMed ID: 17905266
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac output and stroke volume variation measured by the pulse wave transit time method: a comparison with an arterial pressure-based cardiac output system.
    Suzuki T; Suzuki Y; Okuda J; Minoshima R; Misonoo Y; Ueda T; Kato J; Nagata H; Yamada T; Morisaki H
    J Clin Monit Comput; 2019 Jun; 33(3):385-392. PubMed ID: 29948667
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial.
    McGee WT; Horswell JL; Calderon J; Janvier G; Van Severen T; Van den Berghe G; Kozikowski L
    Crit Care; 2007; 11(5):R105. PubMed ID: 17880692
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pulse wave transit time measurements of cardiac output in patients undergoing partial hepatectomy: a comparison of the esCCO system with thermodilution.
    Tsutsui M; Araki Y; Masui K; Kazama T; Sugo Y; Archer TL; Manecke GR
    Anesth Analg; 2013 Dec; 117(6):1307-12. PubMed ID: 24257379
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage.
    Junttila EK; Koskenkari JK; Ohtonen PP; Ala-Kokko TI
    Br J Anaesth; 2011 Oct; 107(4):581-6. PubMed ID: 21693470
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery.
    Lu JK; Zhu C; Jing H; Wang YJ; Qing EM
    Chin Med J (Engl); 2012 Jun; 125(12):2099-103. PubMed ID: 22884136
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.
    Missant C; Rex S; Wouters PF
    Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of a new arterial pulse contour-based cardiac output device.
    de Waal EE; Kalkman CJ; Rex S; Buhre WF
    Crit Care Med; 2007 Aug; 35(8):1904-9. PubMed ID: 17581493
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy of Estimated Continuous Cardiac Output Monitoring (esCCO) Using Pulse Wave Transit Time (PWTT) Compared to Arterial Pressure-based CO (APCO) Measurement during Major Surgeries.
    Joshi M; Rathod R; Bhosale SJ; Kulkarni AP
    Indian J Crit Care Med; 2022; 26(4):496-500. PubMed ID: 35656042
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the Pulse Wave Transit Time Method and an Arterial Pressure-Based Cardiac Output System for Measuring Cardiac Output Trends During Laparotomy Without Postural Change.
    Terada T; Kessoku S; Suzuki A; Kurosawa A; Nakagomi S; Oiwa A; Arai M; Sakamoto N; Idemitsu W; Ochiai R
    Asian J Anesthesiol; 2019 Sep; 57(3):85-92. PubMed ID: 31722470
    [TBL] [Abstract][Full Text] [Related]  