190 related articles for article (PubMed ID: 24859120)
1. [Effects of open or closed suctioning on lung dynamics and hypoxemia in mechanically ventilated patients].
Lee EY; Kim SH
J Korean Acad Nurs; 2014 Apr; 44(2):149-58. PubMed ID: 24859120
[TBL] [Abstract][Full Text] [Related]
2. Comparing the Effects of Two Different Levels of Hyperoxygenation on Gas Exchange During Open Endotracheal Suctioning: A Randomized Crossover Study.
Vianna JR; Pires Di Lorenzo VA; Simões MM; Jamami M
Respir Care; 2017 Jan; 62(1):92-101. PubMed ID: 28003557
[TBL] [Abstract][Full Text] [Related]
3. Changes in lung volume with three systems of endotracheal suctioning with and without pre-oxygenation in patients with mild-to-moderate lung failure.
Fernández MD; Piacentini E; Blanch L; Fernández R
Intensive Care Med; 2004 Dec; 30(12):2210-5. PubMed ID: 15480564
[TBL] [Abstract][Full Text] [Related]
4. Effects of endotracheal suctioning on mixed venous oxygen saturation and heart rate in critically ill adults.
Clark AP; Winslow EH; Tyler DO; White KM
Heart Lung; 1990 Sep; 19(5 Pt 2):552-7. PubMed ID: 2211166
[TBL] [Abstract][Full Text] [Related]
5. [Indications for the use of closed endotracheal suction. Artificial respiration with high positive end-expiratory pressure].
Weitl J; Bettstetter H
Anaesthesist; 1994 Jun; 43(6):359-63. PubMed ID: 8048770
[TBL] [Abstract][Full Text] [Related]
6. Effect of endotracheal suction on lung dynamics in mechanically-ventilated paediatric patients.
Morrow B; Futter M; Argent A
Aust J Physiother; 2006; 52(2):121-6. PubMed ID: 16764549
[TBL] [Abstract][Full Text] [Related]
7. Endotracheal suctioning: ventilator vs manual delivery of hyperoxygenation breaths.
Grap MJ; Glass C; Corley M; Parks T
Am J Crit Care; 1996 May; 5(3):192-7. PubMed ID: 8722922
[TBL] [Abstract][Full Text] [Related]
8. Closed system endotracheal suctioning maintains lung volume during volume-controlled mechanical ventilation.
Cereda M; Villa F; Colombo E; Greco G; Nacoti M; Pesenti A
Intensive Care Med; 2001 Apr; 27(4):648-54. PubMed ID: 11398690
[TBL] [Abstract][Full Text] [Related]
9. Physiologic impact of closed-system endotracheal suctioning in spontaneously breathing patients receiving mechanical ventilation.
Seymour CW; Cross BJ; Cooke CR; Gallop RL; Fuchs BD
Respir Care; 2009 Mar; 54(3):367-74. PubMed ID: 19245731
[TBL] [Abstract][Full Text] [Related]
10. Comparison of loss in lung volume with open versus in-line catheter endotracheal suctioning.
Choong K; Chatrkaw P; Frndova H; Cox PN
Pediatr Crit Care Med; 2003 Jan; 4(1):69-73. PubMed ID: 12656547
[TBL] [Abstract][Full Text] [Related]
11. Effect of different endotracheal suctioning systems on cardiorespiratory parameters of ventilated patients.
Lee CK; Ng KS; Tan SG; Ang R
Ann Acad Med Singap; 2001 May; 30(3):239-44. PubMed ID: 11455735
[TBL] [Abstract][Full Text] [Related]
12. The impact of closed endotracheal suctioning systems on mechanical ventilator performance.
El Masry A; Williams PF; Chipman DW; Kratohvil JP; Kacmarek RM
Respir Care; 2005 Mar; 50(3):345-53. PubMed ID: 15737244
[TBL] [Abstract][Full Text] [Related]
13. Can ventilator settings reduce the negative effects of endotracheal suctioning? Investigations in a mechanical lung model.
Nakstad ER; Opdahl H; Heyerdahl F; Borchsenius F; Skjønsberg OH
BMC Anesthesiol; 2016 Jun; 16(1):30. PubMed ID: 27350249
[TBL] [Abstract][Full Text] [Related]
14. End-expiratory lung volume recovers more slowly after closed endotracheal suctioning than after open suctioning: a randomized crossover study.
Corley A; Spooner AJ; Barnett AG; Caruana LR; Hammond NE; Fraser JF
J Crit Care; 2012 Dec; 27(6):742.e1-7. PubMed ID: 23102530
[TBL] [Abstract][Full Text] [Related]
15. AARC Clinical Practice Guidelines. Endotracheal suctioning of mechanically ventilated patients with artificial airways 2010.
American Association for Respiratory Care
Respir Care; 2010 Jun; 55(6):758-64. PubMed ID: 20507660
[TBL] [Abstract][Full Text] [Related]
16. Effect of oxygen insufflation during endotracheal suctioning on arterial pressure and oxygenation in coronary artery bypass graft patients.
Dam V; Wild MC; Baun MM
Am J Crit Care; 1994 May; 3(3):191-7. PubMed ID: 8038847
[TBL] [Abstract][Full Text] [Related]
17. Effects of open and closed suction systems on the haemodynamic parameters in cardiac surgery patients.
Özden D; Görgülü RS
Nurs Crit Care; 2015 May; 20(3):118-25. PubMed ID: 24991700
[TBL] [Abstract][Full Text] [Related]
18. Effect of lung hyperinflation and endotracheal suctioning on heart rate and rhythm in patients after coronary artery bypass graft surgery.
Stone KS; Talaganis SA; Preusser B; Gonyon DS
Heart Lung; 1991 Sep; 20(5 Pt 1):443-50. PubMed ID: 1894523
[TBL] [Abstract][Full Text] [Related]
19. A recruitment manoeuvre performed after endotracheal suction does not increase dynamic compliance in ventilated paediatric patients: a randomised controlled trial.
Morrow B; Futter M; Argent A
Aust J Physiother; 2007; 53(3):163-9. PubMed ID: 17725473
[TBL] [Abstract][Full Text] [Related]
20. Effects of Zero PEEP and < 1.0 FIO2 on SpO2 and PETCO2 During Open Endotracheal Suctioning.
de Freitas Vianna JR; Pires Di Lorenzo VA; Lourenço da S Simões MM; Guerra JL; Jamami M
Respir Care; 2020 Dec; 65(12):1805-1814. PubMed ID: 32636279
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]