These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 24861607)

  • 1. Sampling reliability, spatial resolution, spatial precision, and extraction efficiency in droplet-based liquid microjunction surface sampling.
    Kertesz V; Van Berkel GJ
    Rapid Commun Mass Spectrom; 2014 Jul; 28(13):1553-60. PubMed ID: 24861607
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An enhanced droplet-based liquid microjunction surface sampling system coupled with HPLC-ESI-MS/MS for spatially resolved analysis.
    Kertesz V; Weiskittel TM; Van Berkel GJ
    Anal Bioanal Chem; 2015 Mar; 407(8):2117-25. PubMed ID: 25377777
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Extraction efficiency and implications for absolute quantitation of propranolol in mouse brain, liver and kidney tissue sections using droplet-based liquid microjunction surface sampling high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.
    Kertesz V; Weiskittel TM; Vavrek M; Freddo C; Van Berkel GJ
    Rapid Commun Mass Spectrom; 2016 Jul; 30(14):1705-1712. PubMed ID: 28328034
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automated liquid microjunction surface sampling-HPLC-MS/MS analysis of drugs and metabolites in whole-body thin tissue sections.
    Kertesz V; Van Berkel GJ
    Bioanalysis; 2013 Apr; 5(7):819-26. PubMed ID: 23534426
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous-flow liquid microjunction surface sampling probe connected on-line with high-performance liquid chromatography/mass spectrometry for spatially resolved analysis of small molecules and proteins.
    Van Berkel GJ; Kertesz V
    Rapid Commun Mass Spectrom; 2013 Jun; 27(12):1329-34. PubMed ID: 23681810
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Liquid microjunction surface sampling coupled with high-pressure liquid chromatography-electrospray ionization-mass spectrometry for analysis of drugs and metabolites in whole-body thin tissue sections.
    Kertesz V; Van Berkel GJ
    Anal Chem; 2010 Jul; 82(14):5917-21. PubMed ID: 20560529
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dispersive liquid-liquid microextraction based on solidification of floating organic droplet followed by high-performance liquid chromatography with ultraviolet detection and liquid chromatography-tandem mass spectrometry for the determination of triclosan and 2,4-dichlorophenol in water samples.
    Zheng C; Zhao J; Bao P; Gao J; He J
    J Chromatogr A; 2011 Jun; 1218(25):3830-6. PubMed ID: 21601213
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Combining laser ablation/liquid phase collection surface sampling and high-performance liquid chromatography-electrospray ionization-mass spectrometry.
    Ovchinnikova OS; Kertesz V; Van Berkel GJ
    Anal Chem; 2011 Mar; 83(6):1874-8. PubMed ID: 21329336
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fully automated laser ablation liquid capture surface analysis using nanoelectrospray ionization mass spectrometry.
    Lorenz M; Ovchinnikova OS; Van Berkel GJ
    Rapid Commun Mass Spectrom; 2014 Jun; 28(11):1312-20. PubMed ID: 24760572
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-throughput mode liquid microjunction surface sampling probe.
    Van Berkel GJ; Kertesz V; King RC
    Anal Chem; 2009 Aug; 81(16):7096-101. PubMed ID: 19606841
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Laser ablation sampling of materials directly into the formed liquid microjunction of a continuous flow surface sampling probe/electrospray ionization emitter for mass spectral analysis and imaging.
    Ovchinnikova OS; Lorenz M; Kertesz V; Van Berkel GJ
    Anal Chem; 2013 Nov; 85(21):10211-7. PubMed ID: 24147556
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry.
    Chen W; Wang L; Van Berkel GJ; Kertesz V; Gan J
    J Chromatogr A; 2016 Mar; 1439():137-143. PubMed ID: 26589943
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Absolute quantitative imaging of sphingolipids in brain tissue by exhaustive liquid microjunction surface sampling-liquid chromatography-mass spectrometry.
    Wu Q; Huang Z; Wang Y; Zhang Z; Lu H
    J Chromatogr A; 2020 Jan; 1609():460436. PubMed ID: 31409489
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of dual solvent-stir bars microextraction and U-shaped hollow fiber-liquid phase microextraction for the analysis of Sudan dyes in food samples by high-performance liquid chromatography-ultraviolet/mass spectrometry.
    Yu C; Liu Q; Lan L; Hu B
    J Chromatogr A; 2008 Apr; 1188(2):124-31. PubMed ID: 18339396
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hydrophobic treatment enabling analysis of wettable surfaces using a liquid microjunction surface sampling probe/electrospray ionization-mass spectrometry system.
    Walworth MJ; Stankovich JJ; Van Berkel GJ; Schulz M; Minarik S; Nichols J; Reich E
    Anal Chem; 2011 Jan; 83(2):591-7. PubMed ID: 21158402
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Green aspects, developments and perspectives of liquid phase microextraction techniques.
    Spietelun A; Marcinkowski Ł; de la Guardia M; Namieśnik J
    Talanta; 2014 Feb; 119():34-45. PubMed ID: 24401382
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Systematic evaluation of supported liquid extraction in reducing matrix effect and improving extraction efficiency in LC-MS/MS based bioanalysis for 10 model pharmaceutical compounds.
    Jiang H; Cao H; Zhang Y; Fast DM
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Apr; 891-892():71-80. PubMed ID: 22410088
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Application of a liquid extraction based sealing surface sampling probe for mass spectrometric analysis of dried blood spots and mouse whole-body thin tissue sections.
    Van Berkel GJ; Kertesz V
    Anal Chem; 2009 Nov; 81(21):9146-52. PubMed ID: 19817477
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High performance liquid chromatography-tandem mass spectrometry for the analysis of 10 pesticides in water: a comparison between membrane-assisted solvent extraction and solid phase extraction.
    van Pinxteren M; Bauer C; Popp P
    J Chromatogr A; 2009 Jul; 1216(31):5800-6. PubMed ID: 19570541
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A high-throughput platform for low-volume high-temperature/pressure sealed vessel solvent extractions.
    Damm M; Kappe CO
    Anal Chim Acta; 2011 Nov; 707(1-2):76-83. PubMed ID: 22027122
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.