These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 24863015)

  • 21. Getting to the (aortic) root of the problem.
    DeAnda A; Balsam LB
    J Thorac Cardiovasc Surg; 2015 Jul; 150(1):77-8. PubMed ID: 25896464
    [No Abstract]   [Full Text] [Related]  

  • 22. Myocardial function and structure in aortic valve disease before and after surgery.
    Krayenbuehl HP; Schneider J; Turina M; Senning A
    Eur Heart J; 1982 Apr; 3 Suppl A():149-53. PubMed ID: 7075617
    [No Abstract]   [Full Text] [Related]  

  • 23. Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis.
    Jilaihawi H; Chin D; Spyt T; Jeilan M; Vasa-Nicotera M; Bence J; Logtens E; Kovac J
    Eur Heart J; 2010 Apr; 31(7):857-64. PubMed ID: 20037145
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Early postoperative outcome and hemodynamic performance of the sorin pericarbon stentless aortic valve.
    Bonacchi M; Giunti G; Prifti E; Rostagno C; Bini M; Frati G; Sani G
    J Heart Valve Dis; 2002 Sep; 11(5):703-9. PubMed ID: 12358408
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Hemodynamic assessment of patients with aortic or mitral valve replacement during exercise (author's transl)].
    Kraus F; Rudolph W
    Herz; 1981 Jun; 6(3):138-47. PubMed ID: 7250886
    [No Abstract]   [Full Text] [Related]  

  • 26. Hemodynamic performance of Trifecta: single-center experience of 400 patients.
    Modi A; Budra M; Miskolczi S; Velissaris T; Kaarne M; Barlow CW; Livesey SA; Ohri SK; Tsang GM
    Asian Cardiovasc Thorac Ann; 2015 Feb; 23(2):140-5. PubMed ID: 24823382
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Aortic valve replacement with bioprostheses in liver transplant recipients.
    Segura I; Herrero JI; Martín A; Saénz de Buruaga JD; Quiroga J; Latorre G; Fernandez E; López-Coronado JL; Sangro B
    J Heart Valve Dis; 2000 May; 9(3):370-3. PubMed ID: 10888093
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of the Carpentier-Edwards Perimount and St. Jude Medical Epic bioprostheses for aortic valve replacement--a retrospective echocardiographic short-term study.
    Goetzenich A; Langebartels G; Christiansen S; Hatam N; Autschbach R; Dohmen G
    J Card Surg; 2009; 24(3):260-4. PubMed ID: 19438778
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Early stenosis of Medtronic Mosaic bioprosthesis in the aortic position.
    Peeceeyen S; Cao C; Fermanis G; Manganas C
    J Thorac Cardiovasc Surg; 2012 Feb; 143(2):e13-4. PubMed ID: 22104666
    [No Abstract]   [Full Text] [Related]  

  • 30. Short-term follow up with the 3f Enable aortic bioprosthesis: clinical and echocardiographic results.
    Concistrè G; Miceli A; Marchi F; Farneti P; Chiaramonti F; Solinas M; Glauber AG
    J Heart Valve Dis; 2013 Nov; 22(6):817-23. PubMed ID: 24597403
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Hemodynamic properties of the glutaraldehyde preserved porcine xenograft valve (author's transl)].
    Maeta H; Sato M; Ohshima N; Matsumoto M; Hiratsuka H; Hori M
    Nihon Kyobu Geka Gakkai Zasshi; 1981 Jan; 29(1):56-62. PubMed ID: 7217738
    [No Abstract]   [Full Text] [Related]  

  • 32. Initial experience with the freestyle stentless aortic bioprosthesis.
    Wong SP; Legget ME; Raudkivi PJ
    N Z Med J; 2000 Jul; 113(1113):266-8. PubMed ID: 10935563
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Of SOLOs and ensembles.
    Blackstone EH
    J Thorac Cardiovasc Surg; 2015 Jul; 150(1):10-1. PubMed ID: 26126454
    [No Abstract]   [Full Text] [Related]  

  • 34. Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses.
    Seiffert M; Conradi L; Baldus S; Knap M; Schirmer J; Franzen O; Koschyk D; Meinertz T; Reichenspurner H; Treede H
    J Thorac Cardiovasc Surg; 2012 Mar; 143(3):617-24. PubMed ID: 22169448
    [TBL] [Abstract][Full Text] [Related]  

  • 35. On explaining the cause with the effect.
    Stanger O; Tevaearai H
    J Thorac Cardiovasc Surg; 2015 Aug; 150(2):432-4. PubMed ID: 26204873
    [No Abstract]   [Full Text] [Related]  

  • 36. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.
    Wagner IM; Eichinger WB; Bleiziffer S; Botzenhardt F; Gebauer I; Guenzinger R; Bauernschmitt R; Lange R
    J Thorac Cardiovasc Surg; 2007 May; 133(5):1234-41. PubMed ID: 17467435
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of the effects of aortic valve replacement using 19-mm Carpentier-Edwards Perimount bioprosthesis and 19-mm Medtronic Mosaic bioprosthesis.
    Tanigawa K; Eishi K; Yamachika S; Hashizume K; Tada S; Yamane K; Izumi K; Takai H; Miura T; Nakaji S
    Ann Thorac Cardiovasc Surg; 2008 Apr; 14(2):81-7. PubMed ID: 18414344
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Transapical valve-in-valve implantation for regurgitant stented aortic bioprostheses.
    Wenaweser P; Pilgrim T; Windecker S; Stortecky S; Carrel T; Kadner A
    J Heart Valve Dis; 2012 May; 21(3):344-9. PubMed ID: 22808836
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The Mosaic porcine bioprosthesis: role of age on clinical performance in aortic position.
    Riess FC; Bader R; Cramer E; Hansen L; Schiffelers S; Wallrath J; Wahl G
    J Thorac Cardiovasc Surg; 2011 Jun; 141(6):1440-8.e1. PubMed ID: 20850804
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Early Antithrombotic Therapy after Bioprosthetic Aortic Valve Replacement in Elderly Patients: A Single-Center Experience.
    Lee SI; Lee KS; Kim JB; Choo SJ; Chung CH; Lee JW; Jung SH
    Ann Thorac Cardiovasc Surg; 2017 Jun; 23(3):128-134. PubMed ID: 28367855
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.