213 related articles for article (PubMed ID: 24869453)
1. Does cochleostomy location influence electrode trajectory and intracochlear trauma?
Zhou L; Friedmann DR; Treaba C; Peng R; Roland JT
Cochlear Implants Int; 2014 May; 15 Suppl 1():S8-S10. PubMed ID: 24869453
[No Abstract] [Full Text] [Related]
2. Does cochleostomy location influence electrode trajectory and intracochlear trauma?
Zhou L; Friedmann DR; Treaba C; Peng R; Roland JT
Laryngoscope; 2015 Apr; 125(4):966-71. PubMed ID: 25345671
[TBL] [Abstract][Full Text] [Related]
3. Cochlear implant electrode insertion: in defence of cochleostomy and factors against the round window membrane approach.
Addams-Williams J; Munaweera L; Coleman B; Shepherd R; Backhouse S
Cochlear Implants Int; 2011 Aug; 12 Suppl 2():S36-9. PubMed ID: 21917217
[TBL] [Abstract][Full Text] [Related]
4. Comparison of round window and cochleostomy approaches with a prototype hearing preservation electrode.
Briggs RJ; Tykocinski M; Xu J; Risi F; Svehla M; Cowan R; Stover T; Erfurt P; Lenarz T
Audiol Neurootol; 2006; 11 Suppl 1():42-8. PubMed ID: 17063010
[TBL] [Abstract][Full Text] [Related]
5. Insertion site and sealing technique affect residual hearing and tissue formation after cochlear implantation.
Burghard A; Lenarz T; Kral A; Paasche G
Hear Res; 2014 Jun; 312():21-7. PubMed ID: 24566091
[TBL] [Abstract][Full Text] [Related]
6. Atraumatic Scala Tympani Cochleostomy; Resolution of the Dilemma.
Badr A; Shabana Y; Mokbel K; Elsharabasy A; Ghonim M; Sanna M
J Int Adv Otol; 2018 Aug; 14(2):190-196. PubMed ID: 30100542
[TBL] [Abstract][Full Text] [Related]
7. Effects of Different Insertion Techniques of a Cochlear Implant Electrode on the Intracochlear Pressure.
Todt I; Ernst A; Mittmann P
Audiol Neurootol; 2016; 21(1):30-7. PubMed ID: 26794906
[TBL] [Abstract][Full Text] [Related]
8. Delayed low frequency hearing loss caused by cochlear implantation interventions via the round window but not cochleostomy.
Rowe D; Chambers S; Hampson A; Eastwood H; Campbell L; O'Leary S
Hear Res; 2016 Mar; 333():49-57. PubMed ID: 26739790
[TBL] [Abstract][Full Text] [Related]
9. Radiologic Results and Hearing Preservation With a Straight Narrow Electrode via Round Window Versus Cochleostomy Approach at Initial Activation.
Hassepass F; Aschendorff A; Bulla S; Arndt S; Maier W; Laszig R; Beck R
Otol Neurotol; 2015 Jul; 36(6):993-1000. PubMed ID: 25675315
[TBL] [Abstract][Full Text] [Related]
10. Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study.
Adunka O; Unkelbach MH; Mack M; Hambek M; Gstoettner W; Kiefer J
Acta Otolaryngol; 2004 Sep; 124(7):807-12. PubMed ID: 15370564
[TBL] [Abstract][Full Text] [Related]
11. Round window insertion of precurved electrodes is traumatic.
Jeyakumar A; Peña SF; Brickman TM
Otol Neurotol; 2014 Jan; 35(1):52-7. PubMed ID: 24270713
[TBL] [Abstract][Full Text] [Related]
12. Round window insertion of precurved perimodiolar electrode arrays: how successful is it?
Souter MA; Briggs RJ; Wright CG; Roland PS
Otol Neurotol; 2011 Jan; 32(1):58-63. PubMed ID: 21131883
[TBL] [Abstract][Full Text] [Related]
13. Cochleostomy site: implications for electrode placement and hearing preservation.
Briggs RJ; Tykocinski M; Stidham K; Roberson JB
Acta Otolaryngol; 2005 Aug; 125(8):870-6. PubMed ID: 16158535
[TBL] [Abstract][Full Text] [Related]
14. Combining perimodiolar electrode placement and atraumatic insertion properties in cochlear implantation -- fact or fantasy?
Adunka OF; Pillsbury HC; Kiefer J
Acta Otolaryngol; 2006 May; 126(5):475-82. PubMed ID: 16698696
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of the hybrid-L24 electrode using microcomputed tomography.
Driscoll CL; Carlson ML; Fama AF; Lane JI
Laryngoscope; 2011 Jul; 121(7):1508-16. PubMed ID: 21541948
[TBL] [Abstract][Full Text] [Related]
16. Benefit of Preoperative Temporal Bone CT for Atraumatic Cochlear Implantation.
Karkas A; Champfleur NM; Uziel A; Mondain M; Puel JL; Venail F
Otol Neurotol; 2018 Mar; 39(3):e186-e194. PubMed ID: 29342055
[TBL] [Abstract][Full Text] [Related]
17. Preservation of basal inner ear structures in cochlear implantation.
Adunka O; Gstoettner W; Hambek M; Unkelbach MH; Radeloff A; Kiefer J
ORL J Otorhinolaryngol Relat Spec; 2004; 66(6):306-12. PubMed ID: 15668529
[TBL] [Abstract][Full Text] [Related]
18. A New Slim Modiolar Electrode Array for Cochlear Implantation: A Radiological and Histological Study.
Iso-Mustajärvi M; Matikka H; Risi F; Sipari S; Koski T; Willberg T; Lehtimäki A; Tervaniemi J; Löppönen H; Dietz A
Otol Neurotol; 2017 Oct; 38(9):e327-e334. PubMed ID: 28796083
[TBL] [Abstract][Full Text] [Related]
19. Lamb Temporal Bone as a Surgical Training Model of Round Window Cochlear Implant Electrode Insertion.
Mantokoudis G; Huth ME; Weisstanner C; Friedrich HM; Nauer C; Candreia C; Caversaccio MD; Senn P
Otol Neurotol; 2016 Jan; 37(1):52-6. PubMed ID: 26649606
[TBL] [Abstract][Full Text] [Related]
20. The new mid-scala electrode array: a radiologic and histologic study in human temporal bones.
Hassepass F; Bulla S; Maier W; Laszig R; Arndt S; Beck R; Traser L; Aschendorff A
Otol Neurotol; 2014 Sep; 35(8):1415-20. PubMed ID: 24836594
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]