These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

65 related articles for article (PubMed ID: 24880376)

  • 21. Micro-computed tomography: a method for the non-destructive evaluation of the three-dimensional structure of biological specimens.
    Stauber M; Müller R
    Methods Mol Biol; 2008; 455():273-92. PubMed ID: 18463825
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Three-dimensional reconstruction using an adaptive simultaneous algebraic reconstruction technique in electron tomography.
    Wan X; Zhang F; Chu Q; Zhang K; Sun F; Yuan B; Liu Z
    J Struct Biol; 2011 Sep; 175(3):277-87. PubMed ID: 21699984
    [TBL] [Abstract][Full Text] [Related]  

  • 23. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.
    Kinahan PE; Hasegawa BH; Beyer T
    Semin Nucl Med; 2003 Jul; 33(3):166-79. PubMed ID: 12931319
    [TBL] [Abstract][Full Text] [Related]  

  • 24. EDART, a discrete algebraic reconstructing technique for experimental data obtained with high resolution computed tomography.
    Brabant L; Dierick M; Pauwels E; Boone MN; Van Hoorebeke L
    J Xray Sci Technol; 2014; 22(1):47-61. PubMed ID: 24463385
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Three-dimensional low-dose CT volume reconstruction based on non-local weights optimization and GPU acceleration].
    Zhang XL; Tian LL; Huang J; Ma JH; Zhang H; Feng QJ; Chen WF
    Nan Fang Yi Ke Da Xue Xue Bao; 2011 Dec; 31(12):1974-80. PubMed ID: 22200694
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An iterative maximum-likelihood polychromatic algorithm for CT.
    De Man B; Nuyts J; Dupont P; Marchal G; Suetens P
    IEEE Trans Med Imaging; 2001 Oct; 20(10):999-1008. PubMed ID: 11686446
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A local region of interest image reconstruction via filtered backprojection for fan-beam differential phase-contrast computed tomography.
    Qi Z; Chen GH
    Phys Med Biol; 2007 Sep; 52(18):N417-23. PubMed ID: 17804875
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A modified conjugate gradient method based on the Tikhonov system for computerized tomography (CT).
    Wang Q; Wang H
    ISA Trans; 2011 Apr; 50(2):256-61. PubMed ID: 21129739
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Statistical content-adapted sampling (SCAS) for 3D Computed Tomography.
    Cazasnoves A; Sevestre S; Buyens F; Peyrin F
    Comput Biol Med; 2018 Jan; 92():9-21. PubMed ID: 29132015
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Free isocentric 3d imaging and a novel approach for wobble trajectories using a modified standard c-arm.
    Tita R; Lueth TC
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():4418-21. PubMed ID: 18002984
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Myoanatomy of the velvet worm leg revealed by laboratory-based nanofocus X-ray source tomography.
    Müller M; de Sena Oliveira I; Allner S; Ferstl S; Bidola P; Mechlem K; Fehringer A; Hehn L; Dierolf M; Achterhold K; Gleich B; Hammel JU; Jahn H; Mayer G; Pfeiffer F
    Proc Natl Acad Sci U S A; 2017 Nov; 114(47):12378-12383. PubMed ID: 29109262
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Physico-mathematical considerations on x-ray computed tomography based on diffraction enhanced imaging.
    Yuasa T; Maksimenko A; Hashimoto E; Akatsuka T; Ando M
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():4441-4. PubMed ID: 18002990
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Fast minimum variance estimator for limited angle CT image reconstruction.
    Buonocore MH; Brody WR; Macovski A
    Med Phys; 1981; 8(5):695-702. PubMed ID: 7290021
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Computed tomography from ordinary radiographs for teleradiology.
    Rangayyan RM; Gordon R
    Med Phys; 1983; 10(5):687-90. PubMed ID: 6646077
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Quantitative imaging of Candida utilis and its organelles by soft X-ray Nano-CT.
    Liu J; Li F; Chen L; Guan Y; Tian L; Xiong Y; Liu G; Tian Y
    J Microsc; 2018 Apr; 270(1):64-70. PubMed ID: 28960304
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Introduction: a brief overview of iterative algorithms in X-ray computed tomography.
    Soleimani M; Pengpen T
    Philos Trans A Math Phys Eng Sci; 2015 Jun; 373(2043):. PubMed ID: 25939624
    [TBL] [Abstract][Full Text] [Related]  

  • 37. X-ray phase-contrast imaging with nanoradian angular resolution.
    Diemoz PC; Endrizzi M; Zapata CE; Pešić ZD; Rau C; Bravin A; Robinson IK; Olivo A
    Phys Rev Lett; 2013 Mar; 110(13):138105. PubMed ID: 23581380
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Perturbation Resilience and Superiorization of Iterative Algorithms.
    Censor Y; Davidi R; Herman GT
    Inverse Probl; 2010 Jun; 26(6):65008. PubMed ID: 20613969
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Line-source based x-ray tomography.
    Bharkhada D; Yu H; Liu H; Plemmons R; Wang G
    Int J Biomed Imaging; 2009; 2009():534516. PubMed ID: 19436708
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Computed tomography in various fields outside medicine.
    van Kaick G; Delorme S
    Eur Radiol; 2005 Nov; 15 Suppl 4():D74-81. PubMed ID: 16479652
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.