BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

211 related articles for article (PubMed ID: 24880678)

  • 1. Analysis of the EBT3 Gafchromic film irradiated with 6 MV photons and 6 MeV electrons using reflective mode scanners.
    Farah N; Francis Z; Abboud M
    Phys Med; 2014 Sep; 30(6):708-12. PubMed ID: 24880678
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of Gafchromic® EBT3 films characteristics in therapy photon, electron and proton beams.
    Sorriaux J; Kacperek A; Rossomme S; Lee JA; Bertrand D; Vynckier S; Sterpin E
    Phys Med; 2013 Nov; 29(6):599-606. PubMed ID: 23107430
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Gafchromic EBT3 film dosimetry in electron beams - energy dependence and improved film read-out.
    Sipilä P; Ojala J; Kaijaluoto S; Jokelainen I; Kosunen A
    J Appl Clin Med Phys; 2016 Jan; 17(1):360-373. PubMed ID: 26894368
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry.
    Lewis D; Chan MF
    Med Phys; 2015 Jan; 42(1):416-29. PubMed ID: 25563282
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.
    Jaccard M; Petersson K; Buchillier T; Germond JF; Durán MT; Vozenin MC; Bourhis J; Bochud FO; Bailat C
    Med Phys; 2017 Feb; 44(2):725-735. PubMed ID: 28019660
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and (60)Co γ-rays.
    Vadrucci M; Esposito G; Ronsivalle C; Cherubini R; Marracino F; Montereali RM; Picardi L; Piccinini M; Pimpinella M; Vincenti MA; De Angelis C
    Med Phys; 2015 Aug; 42(8):4678-84. PubMed ID: 26233195
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Technical Note: On GAFChromic EBT-XD film and the lateral response artifact.
    Lewis DF; Chan MF
    Med Phys; 2016 Feb; 43(2):643-9. PubMed ID: 26843228
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
    Ferreira BC; Lopes MC; Capela M
    Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Magnetic fields are causing small, but significant changes of the radiochromic EBT3 film response to 6 MV photons.
    Delfs B; Schoenfeld AA; Poppinga D; Kapsch RP; Jiang P; Harder D; Poppe B; Looe HK
    Phys Med Biol; 2018 Jan; 63(3):035028. PubMed ID: 29155691
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams.
    Brown TA; Hogstrom KR; Alvarez D; Matthews KL; Ham K; Dugas JP
    Med Phys; 2012 Dec; 39(12):7412-7. PubMed ID: 23231291
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Variations in dose distribution and optical properties of Gafchromic(TM) EBT2 film according to scanning mode.
    Park S; Kang SK; Cheong KH; Hwang T; Kim H; Han T; Lee MY; Kim K; Bae H; Su Kim H; Han Kim J; Jae Oh S; Suh JS
    Med Phys; 2012 May; 39(5):2524-35. PubMed ID: 22559623
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radiochromic film dosimetry: considerations on precision and accuracy for EBT2 and EBT3 type films.
    Dreindl R; Georg D; Stock M
    Z Med Phys; 2014 May; 24(2):153-63. PubMed ID: 24055395
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Absolute dosimetric characterization of Gafchromic EBT3 and HDv2 films using commercial flat-bed scanners and evaluation of the scanner response function variability.
    Chen SN; Gauthier M; Bazalova-Carter M; Bolanos S; Glenzer S; Riquier R; Revet G; Antici P; Morabito A; Propp A; Starodubtsev M; Fuchs J
    Rev Sci Instrum; 2016 Jul; 87(7):073301. PubMed ID: 27475550
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A new correction method serving to eliminate the parabola effect of flatbed scanners used in radiochromic film dosimetry.
    Poppinga D; Schoenfeld AA; Doerner KJ; Blanck O; Harder D; Poppe B
    Med Phys; 2014 Feb; 41(2):021707. PubMed ID: 24506598
    [TBL] [Abstract][Full Text] [Related]  

  • 15. SU-E-T-128: Dosimetric Characteristics of Gafchromic EBT3 Films for Megavoltage Photon and Proton Beams.
    Hayashi N; Kato H; Yada R; Matsunaga T; Ehara I; Adachi Y
    Med Phys; 2012 Jun; 39(6Part11):3732. PubMed ID: 28517145
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Technical note: Energy dependence of the Gafchromic EBT4 film: Dose-response curves for 70 kV, 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV x-ray beams.
    Chan MF; Park J; Aydin R; Lim SB
    Med Phys; 2023 Jun; 50(6):3738-3745. PubMed ID: 36695666
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiochromic film calibration for low-energy seed brachytherapy dose measurement.
    Morrison H; Menon G; Sloboda RS
    Med Phys; 2014 Jul; 41(7):072101. PubMed ID: 24989396
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry.
    Moylan R; Aland T; Kairn T
    Australas Phys Eng Sci Med; 2013 Sep; 36(3):331-7. PubMed ID: 23801092
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spectral analysis of the EBT3 radiochromic films for clinical photon and electron beams.
    León-Marroquín EY; Mulrow DJ; Khan R; Darafsheh A
    Med Phys; 2019 Feb; 46(2):973-982. PubMed ID: 30536832
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams.
    Khachonkham S; Dreindl R; Heilemann G; Lechner W; Fuchs H; Palmans H; Georg D; Kuess P
    Phys Med Biol; 2018 Mar; 63(6):065007. PubMed ID: 29474189
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.