751 related articles for article (PubMed ID: 24882594)
1. The effect of platform switching on stress distribution in implants and periimplant bone studied by nonlinear finite element analysis.
Liu S; Tang C; Yu J; Dai W; Bao Y; Hu D
J Prosthet Dent; 2014 Nov; 112(5):1111-8. PubMed ID: 24882594
[TBL] [Abstract][Full Text] [Related]
2. Effect of platform connection and abutment material on stress distribution in single anterior implant-supported restorations: a nonlinear 3-dimensional finite element analysis.
Carvalho MA; Sotto-Maior BS; Del Bel Cury AA; Pessanha Henriques GE
J Prosthet Dent; 2014 Nov; 112(5):1096-102. PubMed ID: 24831744
[TBL] [Abstract][Full Text] [Related]
3. Effects of the implant design on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis of original computer-aided design models.
Yamanishi Y; Yamaguchi S; Imazato S; Nakano T; Yatani H
J Periodontol; 2014 Sep; 85(9):e333-8. PubMed ID: 24835549
[TBL] [Abstract][Full Text] [Related]
4. The effect of placement depth of platform-switched implants on periimplant cortical bone stress: a 3-dimensional finite element analysis.
Rismanchian M; Askari N; Shafiei S
Implant Dent; 2013 Apr; 22(2):165-9. PubMed ID: 23416848
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical effect of platform switching in implant dentistry: a three-dimensional finite element analysis.
Chang CL; Chen CS; Hsu ML
Int J Oral Maxillofac Implants; 2010; 25(2):295-304. PubMed ID: 20369087
[TBL] [Abstract][Full Text] [Related]
6. Comparison of strain generated in bone by "platform-switched" and "non-platform-switched" implants with straight and angulated abutments under vertical and angulated load: a finite element analysis study.
Paul S; Padmanabhan TV; Swarup S
Indian J Dent Res; 2013; 24(1):8-13. PubMed ID: 23852226
[TBL] [Abstract][Full Text] [Related]
7. Analyzing the effects of the platform-switching procedure on stresses in the bone and implant-abutment complex by 3-dimensional fem analysis.
Cimen H; Yengin E
J Oral Implantol; 2012 Feb; 38(1):21-6. PubMed ID: 20662671
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.
Merıç G; Erkmen E; Kurt A; Eser A; özden AU
Acta Odontol Scand; 2011 Nov; 69(6):374-84. PubMed ID: 21449688
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of Platform Switching on Crestal Bone Stress in Tapered and Cylindrical Implants: A Finite Element Analysis.
Rasouli-Ghahroudi AA; Geramy A; Yaghobee S; Khorsand A; Yousefifakhr H; Rokn A; Soolari A
J Int Acad Periodontol; 2015 Jan; 17(1):2-13. PubMed ID: 26233968
[TBL] [Abstract][Full Text] [Related]
10. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants.
Ding X; Liao SH; Zhu XH; Zhang XH; Zhang L
Clin Implant Dent Relat Res; 2009 Dec; 11(4):279-87. PubMed ID: 18783411
[TBL] [Abstract][Full Text] [Related]
11. Study and characterization of the crest module design: A 3D finite element analysis.
Costa C; Peixinho N; Silva JP; Carvalho S
J Prosthet Dent; 2015 Jun; 113(6):541-7. PubMed ID: 25794909
[TBL] [Abstract][Full Text] [Related]
12. Influence of different abutment diameter of implants on the peri-implant stress in the crestal bone: A three-dimensional finite element analysis--In vitro study.
Aradya A; Kumar UK; Chowdhary R
Indian J Dent Res; 2016; 27(1):78-85. PubMed ID: 27054866
[TBL] [Abstract][Full Text] [Related]
13. Platform switching: biomechanical evaluation using three-dimensional finite element analysis.
Tabata LF; Rocha EP; Barão VA; Assunção WG
Int J Oral Maxillofac Implants; 2011; 26(3):482-91. PubMed ID: 21691594
[TBL] [Abstract][Full Text] [Related]
14. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis.
Bulaqi HA; Mousavi Mashhadi M; Safari H; Samandari MM; Geramipanah F
J Prosthet Dent; 2015 Jun; 113(6):548-57. PubMed ID: 25794917
[TBL] [Abstract][Full Text] [Related]
15. Three-Dimensional Finite Element Analysis of the Biomechanical Behaviors of Implants with Different Connections, Lengths, and Diameters Placed in the Maxillary Anterior Region.
Borie E; Orsi IA; Noritomi PY; Kemmoku DT
Int J Oral Maxillofac Implants; 2016; 31(1):101-10. PubMed ID: 26478969
[TBL] [Abstract][Full Text] [Related]
16. Effect of crown to implant ratio and implant dimensions on periimplant stress of splinted implant-supported crowns: a finite element analysis.
Bayraktar M; Gultekin BA; Yalcin S; Mijiritsky E
Implant Dent; 2013 Aug; 22(4):406-13. PubMed ID: 23823738
[TBL] [Abstract][Full Text] [Related]
17. Should oral implants be splinted in a mandibular implant-supported fixed complete denture? A 3-dimensional-model finite element analysis.
Alvarez-Arenal A; Brizuela-Velasco A; DeLlanos-Lanchares H; Gonzalez-Gonzalez I
J Prosthet Dent; 2014 Sep; 112(3):508-14. PubMed ID: 24560983
[TBL] [Abstract][Full Text] [Related]
18. Regular and platform switching: bone stress analysis varying implant type.
Gurgel-Juarez NC; de Almeida EO; Rocha EP; Freitas AC; Anchieta RB; de Vargas LC; Kina S; França FM
J Prosthodont; 2012 Apr; 21(3):160-6. PubMed ID: 22372756
[TBL] [Abstract][Full Text] [Related]
19. Finite element analysis of an implant-assisted removable partial denture during bilateral loading: occlusal rests position.
Shahmiri R; Das R; Aarts JM; Bennani V
J Prosthet Dent; 2014 Nov; 112(5):1126-33. PubMed ID: 24951387
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical aspects of bone-level diameter shifting at implant-abutment interface.
Canay S; Akça K
Implant Dent; 2009 Jun; 18(3):239-48. PubMed ID: 19509534
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]