These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. A comparison of two semi-quantitative surgical keratometers: the modified Hyde ruler and the Barrett keratoscope with "astigmatic dial". Morlet N; Lindsay P; Cooke P Ophthalmic Surg; 1994 Mar; 25(3):144-9. PubMed ID: 8196916 [TBL] [Abstract][Full Text] [Related]
3. Intraoperative semiquantitative keratometry using the keratoscopic astigmatic ruler. Morlet N; Lindsay PA J Cataract Refract Surg; 1995 Nov; 21(6):616-9. PubMed ID: 8551436 [TBL] [Abstract][Full Text] [Related]
4. Experimental modification of the corneal curvature by means of scleral surgery. Arciniegas A; Amaya LE Ann Ophthalmol; 1984 Dec; 16(12):1155-66. PubMed ID: 6532291 [TBL] [Abstract][Full Text] [Related]
5. Clinical utility of the Barrett keratoscope with astigmatic dial. Morlet N Ophthalmic Surg; 1994 Mar; 25(3):150-3. PubMed ID: 8196917 [TBL] [Abstract][Full Text] [Related]
7. [Semitrepanation of the cornea in severe postoperative astigmatism. A new surgical instrument]. Alberth B; Süveges I Klin Monbl Augenheilkd; 1982 Dec; 181(6):499-500. PubMed ID: 7169778 [No Abstract] [Full Text] [Related]
8. [Our initial experience with the surgical correction of astigmatism by sectorial keratorrhaphy]. Krasnov MM; Avetisov SE; Nazarova NN; Nikol'skaia GM Vestn Oftalmol; 1989; 105(5):3-8. PubMed ID: 2688264 [TBL] [Abstract][Full Text] [Related]
9. A computerized corneal topographer for use in refractive surgery. el Hage SG Refract Corneal Surg; 1989; 5(6):418-24. PubMed ID: 2488841 [No Abstract] [Full Text] [Related]
10. Surgically induced astigmatism after phacoemulsification in eyes with mild to moderate corneal astigmatism: temporal versus on-axis clear corneal incisions. Borasio E; Mehta JS; Maurino V J Cataract Refract Surg; 2006 Apr; 32(4):565-72. PubMed ID: 16698473 [TBL] [Abstract][Full Text] [Related]
11. Pellucid marginal corneal degeneration 12 years after penetrating keratoplasty for keratoconus. Chesnutt DA; Cohen KL Cornea; 1998 Mar; 17(2):236-8. PubMed ID: 9520207 [TBL] [Abstract][Full Text] [Related]
12. An instrument for corneal polishing. McPherson SD Trans Am Ophthalmol Soc; 1971; 69():353-4. PubMed ID: 5154268 [No Abstract] [Full Text] [Related]
13. [Two new types of keratoscope and their clinical application]. Shi MG Zhonghua Yan Ke Za Zhi; 1993 Mar; 29(2):117-9. PubMed ID: 8404355 [TBL] [Abstract][Full Text] [Related]
14. Surgical keratometer in the management of astigmatism in keratoplasty. Troutman RC Ann Ophthalmol; 1987 Dec; 19(12):473-4. PubMed ID: 3426050 [No Abstract] [Full Text] [Related]
15. Computer-assisted corneal topography. High-resolution graphic presentation and analysis of keratoscopy. Klyce SD Invest Ophthalmol Vis Sci; 1984 Dec; 25(12):1426-35. PubMed ID: 6511226 [TBL] [Abstract][Full Text] [Related]
16. Inverse arcuate incision: a new approach to the correction of astigmatism. Thornton SP J Refract Corneal Surg; 1994; 10(1):27-30. PubMed ID: 7517776 [TBL] [Abstract][Full Text] [Related]
17. Reliable keratometry with a new hand held surgical keratometer: calibration of the keratoscopic astigmatic ruler. Morlet N; Maloof A; Wingate N; Lindsay P Br J Ophthalmol; 1998 Jan; 82(1):35-8. PubMed ID: 9536877 [TBL] [Abstract][Full Text] [Related]
18. Comparison of surgically induced astigmatism of temporal versus superior clear corneal incisions. Marek R; Kluś A; Pawlik R Klin Oczna; 2006; 108(10-12):392-6. PubMed ID: 17455711 [TBL] [Abstract][Full Text] [Related]
19. LASIK for hyperopia, hyperopic astigmatism, and mixed astigmatism: a report by the American Academy of Ophthalmology. Varley GA; Huang D; Rapuano CJ; Schallhorn S; Boxer Wachler BS; Sugar A; Ophthalmology; 2004 Aug; 111(8):1604-17. PubMed ID: 15288995 [TBL] [Abstract][Full Text] [Related]