These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 24890298)

  • 1. Staged treatment of proximal tibial fracture using external locking compression plate.
    Ebraheim NA; Carroll T; Hanna M; Zhang J; Liu J
    Orthop Surg; 2014 May; 6(2):154-7. PubMed ID: 24890298
    [TBL] [Abstract][Full Text] [Related]  

  • 2. External fixation using femoral less invasive stabilization system plate in tibial proximal metaphyseal fracture.
    Zhang J; Ebraheim N; Li M; He X; Liu J; Zhu L; Yu Y
    Clin Orthop Surg; 2015 Mar; 7(1):8-14. PubMed ID: 25729513
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.
    Kim JW; Oh CW; Oh JK; Kyung HS; Park KH; Kim HJ; Jung JW; Jung YS
    Injury; 2017 Jun; 48(6):1190-1193. PubMed ID: 28320508
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study.
    Liu W; Yang L; Kong X; An L; Hong G; Guo Z; Zang L
    BMC Musculoskelet Disord; 2017 Jan; 18(1):26. PubMed ID: 28103852
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Distal tibial nonunion using a contralateral anterior L-shaped locking compression plate through a posterior-lateral approach: A retrospective case series.
    Lin C; Lin L; Vinesh L; Shao X; Lu X; Hong J
    Injury; 2017 Jun; 48(6):1224-1228. PubMed ID: 28342545
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative biomechanical analysis of three implants used in bicondylar tibial fractures.
    Faur CI; Niculescu B
    Wien Med Wochenschr; 2018 Jun; 168(9-10):254-260. PubMed ID: 28299551
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis.
    Blažević D; Kodvanj J; Adamović P; Vidović D; Trobonjača Z; Sabalić S
    J Orthop Surg Res; 2022 Jan; 17(1):16. PubMed ID: 35016716
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Metaphyseal locking plate as an external fixator for open tibial fracture: Clinical outcomes and biomechanical assessment.
    Ma CH; Wu CH; Jiang JR; Tu YK; Lin TS
    Injury; 2017 Feb; 48(2):501-505. PubMed ID: 27919511
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.
    Gupta RK; Rohilla RK; Sangwan K; Singh V; Walia S
    Int Orthop; 2010 Dec; 34(8):1285-90. PubMed ID: 19820935
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Locking plate external fixation combined with membrane induction technology for the treatment of open and comminuted tibial fractures with bone defects].
    Zhou SQ; Zhang Q; Ding XD; Qin YY; Cai S
    Zhongguo Gu Shang; 2021 May; 34(5):400-5. PubMed ID: 34032040
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].
    Zeman P; Zeman J; Matejka J; Koudela K
    Acta Chir Orthop Traumatol Cech; 2008 Dec; 75(6):457-64. PubMed ID: 19150004
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Early results with the new internal fixator systems LCP and LISS: a prospective study.
    Hernanz González Y; Díaz Martín A; Jara Sánchez F; Resines Erasun C
    Acta Orthop Belg; 2007 Feb; 73(1):60-9. PubMed ID: 17441660
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Percutaneous bridge plating of extra-articular distal fibular fracture for the management of distal tibia type III open fracture.
    Jung GH; Chung H; Baek SH; Sohn HS
    Asian J Surg; 2021 Jan; 44(1):363-368. PubMed ID: 33092962
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop.
    Qiu XS; Yuan H; Zheng X; Wang JF; Xiong J; Chen YX
    Arch Orthop Trauma Surg; 2014 Mar; 134(3):383-8. PubMed ID: 24362495
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Irreducible tibial pilon fracture caused by incarceration of the fibula in the tibial medullary canal.
    Ellanti P; Hammad Y; Kosutic D; Grieve PP
    J Foot Ankle Surg; 2012; 51(3):362-4. PubMed ID: 22153657
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures--clinical outcome and a finite element study.
    Ma CH; Wu CH; Tu YK; Lin TS
    Injury; 2013 Aug; 44(8):1097-101. PubMed ID: 23706173
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Locking compression plate as an external fixator in the treatment of closed distal tibial fractures.
    Zhou Y; Wang Y; Liu L; Zhou Z; Cao X
    Int Orthop; 2015 Nov; 39(11):2227-37. PubMed ID: 26183145
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Plating of the fibula. Its potential value as an adjunct to external fixation of the tibia.
    Morrison KM; Ebraheim NA; Southworth SR; Sabin JJ; Jackson WT
    Clin Orthop Relat Res; 1991 May; (266):209-13. PubMed ID: 2019053
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Combination of plate and external fixator for biological osteosynthesis of comminuted fractures].
    Pippow A; Krähenbühl L; Michel MC; Witschger P
    Swiss Surg; 2002; 8(5):230-6. PubMed ID: 12422770
    [TBL] [Abstract][Full Text] [Related]  

  • 20. External fixation of tibial plafond fractures: is routine plating of the fibula necessary?
    Williams TM; Marsh JL; Nepola JV; DeCoster TA; Hurwitz SR; Bonar SB
    J Orthop Trauma; 1998 Jan; 12(1):16-20. PubMed ID: 9447514
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.