These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: a single-center prospective pilot study (MOSE study). Iwashita T; Yasuda I; Mukai T; Doi S; Nakashima M; Uemura S; Mabuchi M; Shimizu M; Hatano Y; Hara A; Moriwaki H Gastrointest Endosc; 2015 Jan; 81(1):177-85. PubMed ID: 25440688 [TBL] [Abstract][Full Text] [Related]
6. The 25-gauge EUS-FNA needle: Good for on-site but poor for off-site evaluation? Results of a randomized trial. Varadarajulu S; Bang JY; Holt BA; Hasan MK; Logue A; Hawes RH; Hebert-Magee S Gastrointest Endosc; 2014 Dec; 80(6):1056-63. PubMed ID: 24973173 [TBL] [Abstract][Full Text] [Related]
7. "Wet suction technique (WEST)": a novel way to enhance the quality of EUS-FNA aspirate. Results of a prospective, single-blind, randomized, controlled trial using a 22-gauge needle for EUS-FNA of solid lesions. Attam R; Arain MA; Bloechl SJ; Trikudanathan G; Munigala S; Bakman Y; Singh M; Wallace T; Henderson JB; Catalano MF; Guda NM Gastrointest Endosc; 2015; 81(6):1401-7. PubMed ID: 25733127 [TBL] [Abstract][Full Text] [Related]
8. High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions. Iwashita T; Nakai Y; Samarasena JB; Park DH; Zhang Z; Gu M; Lee JG; Chang KJ Gastrointest Endosc; 2013 Jun; 77(6):909-15. PubMed ID: 23433596 [TBL] [Abstract][Full Text] [Related]
9. Slow pull versus suction in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid masses. Nakai Y; Isayama H; Chang KJ; Yamamoto N; Hamada T; Uchino R; Mizuno S; Miyabayashi K; Yamamoto K; Kawakubo K; Kogure H; Sasaki T; Hirano K; Tanaka M; Tada M; Fukayama M; Koike K Dig Dis Sci; 2014 Jul; 59(7):1578-85. PubMed ID: 24429514 [TBL] [Abstract][Full Text] [Related]
10. Slow-pull and different conventional suction techniques in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid lesions using 22-gauge needles. Chen JY; Ding QY; Lv Y; Guo W; Zhi FC; Liu SD; Cheng TM World J Gastroenterol; 2016 Oct; 22(39):8790-8797. PubMed ID: 27818594 [TBL] [Abstract][Full Text] [Related]
11. Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles. Yang MJ; Yim H; Hwang JC; Lee D; Kim YB; Lim SG; Kim SS; Kang JK; Yoo BM; Kim JH BMC Gastroenterol; 2015 Sep; 15():122. PubMed ID: 26419845 [TBL] [Abstract][Full Text] [Related]
12. Diagnostic ability of EUS-FNA for pancreatic solid lesions with conventional 22-gauge needle using the slow pull technique: a prospective study. Kin T; Katanuma A; Yane K; Takahashi K; Osanai M; Takaki R; Matsumoto K; Gon K; Matsumori T; Tomonari A; Maguchi H; Shinohara T; Nojima M Scand J Gastroenterol; 2015 Jul; 50(7):900-7. PubMed ID: 25732902 [TBL] [Abstract][Full Text] [Related]
13. Stylet slow-pull versus standard suction for endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic lesions: a multicenter randomized trial. Saxena P; El Zein M; Stevens T; Abdelgelil A; Besharati S; Messallam A; Kumbhari V; Azola A; Brainard J; Shin EJ; Lennon AM; Canto MI; Singh VK; Khashab MA Endoscopy; 2018 May; 50(5):497-504. PubMed ID: 29272906 [TBL] [Abstract][Full Text] [Related]
14. Endoscopic ultrasound-guided fine needle aspiration and biopsy using a 22-gauge needle with side fenestration in pancreatic cystic lesions. Barresi L; Tarantino I; Traina M; Granata A; Curcio G; Azzopardi N; Baccarini P; Liotta R; Fornelli A; Maimone A; Jovine E; Cennamo V; Fabbri C Dig Liver Dis; 2014 Jan; 46(1):45-50. PubMed ID: 23916241 [TBL] [Abstract][Full Text] [Related]
15. EUS-guided reverse bevel fine-needle biopsy sampling and open tip fine-needle aspiration in solid pancreatic lesions - a prospective, comparative study. Hedenström P; Demir A; Khodakaram K; Nilsson O; Sadik R Scand J Gastroenterol; 2018 Feb; 53(2):231-237. PubMed ID: 29301477 [TBL] [Abstract][Full Text] [Related]
16. Endoscopic ultrasound-guided tissue sampling by combined fine needle aspiration and trucut needle biopsy: a prospective study. Wittmann J; Kocjan G; Sgouros SN; Deheragoda M; Pereira SP Cytopathology; 2006 Feb; 17(1):27-33. PubMed ID: 16417562 [TBL] [Abstract][Full Text] [Related]
17. Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience. Yusuf TE; Ho S; Pavey DA; Michael H; Gress FG Endoscopy; 2009 May; 41(5):445-8. PubMed ID: 19418399 [TBL] [Abstract][Full Text] [Related]
18. Comparison of the diagnostic performance of 2 core biopsy needles for EUS-guided tissue acquisition from solid pancreatic lesions. Nayar MK; Paranandi B; Dawwas MF; Leeds JS; Darne A; Haugk B; Majumdar D; Ahmed MM; Oppong KW Gastrointest Endosc; 2017 May; 85(5):1017-1024. PubMed ID: 27633157 [TBL] [Abstract][Full Text] [Related]
19. A pilot study of EUS-guided through-the-needle forceps biopsy (with video). Nakai Y; Isayama H; Chang KJ; Yamamoto N; Mizuno S; Mohri D; Kogure H; Matsubara S; Tada M; Koike K Gastrointest Endosc; 2016 Jul; 84(1):158-62. PubMed ID: 26772889 [TBL] [Abstract][Full Text] [Related]
20. EUS-guided fine needle tissue acquisition by using high negative pressure suction for the evaluation of solid masses: a pilot study. Larghi A; Noffsinger A; Dye CE; Hart J; Waxman I Gastrointest Endosc; 2005 Nov; 62(5):768-74. PubMed ID: 16246694 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]