These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 24890996)

  • 1. Can post-cam function be replaced by addition of a third condyle in PS TKA?
    Nakamura S; Sharma A; Nakamura K; Ikeda N; Zingde SM; Komistek RD
    J Arthroplasty; 2014 Sep; 29(9):1871-6. PubMed ID: 24890996
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo kinematic effects of ball and socket third condyle as a post-cam mechanism in tri-condylar knee implants.
    Nakamura S; Sharma A; Nakamura K; Ikeda N; Kawai J; Zingde SM; Komistek RD
    Knee; 2015 Jun; 22(3):237-42. PubMed ID: 25835265
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bicruciate-stabilised total knee arthroplasty provides good functional stability during high-flexion weight-bearing activities.
    Kono K; Inui H; Tomita T; Yamazaki T; Taketomi S; Sugamoto K; Tanaka S
    Knee Surg Sports Traumatol Arthrosc; 2019 Jul; 27(7):2096-2103. PubMed ID: 30972466
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo determination of cam-post engagement in fixed and mobile-bearing TKA.
    Zingde SM; Leszko F; Sharma A; Mahfouz MR; Komistek RD; Dennis DA
    Clin Orthop Relat Res; 2014 Jan; 472(1):254-62. PubMed ID: 23990448
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs.
    Arnout N; Vanlommel L; Vanlommel J; Luyckx JP; Labey L; Innocenti B; Victor J; Bellemans J
    Knee Surg Sports Traumatol Arthrosc; 2015 Nov; 23(11):3343-53. PubMed ID: 25047792
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In Vivo Kinematic Comparison of a Bicruciate Stabilized Total Knee Arthroplasty and the Normal Knee Using Fluoroscopy.
    Grieco TF; Sharma A; Dessinger GM; Cates HE; Komistek RD
    J Arthroplasty; 2018 Feb; 33(2):565-571. PubMed ID: 29066105
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 3D in vivo femoro-tibial kinematics of tri-condylar total knee arthroplasty during kneeling activities.
    Nakamura S; Sharma A; Kobayashi M; Ito H; Nakamura K; Zingde SM; Nakamura T; Komistek RD
    Knee; 2014 Jan; 21(1):162-7. PubMed ID: 24055271
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis.
    Dennis DA; Komistek RD; Colwell CE; Ranawat CS; Scott RD; Thornhill TS; Lapp MA
    Clin Orthop Relat Res; 1998 Nov; (356):47-57. PubMed ID: 9917667
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Semi-constrained posterior stabilized total knee arthroplasty reproduces natural deep knee bending kinematics.
    Sumino T; Tomita T; Sugamoto K; Yamazaki T; Okazaki K
    BMC Musculoskelet Disord; 2020 Feb; 21(1):107. PubMed ID: 32066423
    [TBL] [Abstract][Full Text] [Related]  

  • 10. No difference in range of motion between ultracongruent and posterior stabilized design in total knee arthroplasty: a randomized controlled trial.
    Lützner J; Beyer F; Dexel J; Fritzsche H; Lützner C; Kirschner S
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3515-3521. PubMed ID: 27659044
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Post-Cam Design and Contact Stress on Tibial Posts in Posterior-Stabilized Total Knee Prostheses: Comparison Between a Rounded and a Squared Design.
    Watanabe T; Koga H; Horie M; Katagiri H; Sekiya I; Muneta T
    J Arthroplasty; 2017 Dec; 32(12):3757-3762. PubMed ID: 28780225
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Joint distraction force changes the three-dimensional articulation of the femur and tibia in total knee arthroplasty: a cadaveric study.
    Wada K; Hamada D; Takasago T; Nitta A; Goto T; Tonogai I; Tsuruo Y; Sairyo K
    Knee Surg Sports Traumatol Arthrosc; 2020 May; 28(5):1488-1496. PubMed ID: 31165182
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Customized versus Patient-Sized Cruciate-Retaining Total Knee Arthroplasty: An In Vivo Kinematics Study Using Mobile Fluoroscopy.
    Zeller IM; Sharma A; Kurtz WB; Anderle MR; Komistek RD
    J Arthroplasty; 2017 Apr; 32(4):1344-1350. PubMed ID: 27814916
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanics of post-cam engagement during simulated dynamic activity.
    Fitzpatrick CK; Clary CW; Cyr AJ; Maletsky LP; Rullkoetter PJ
    J Orthop Res; 2013 Sep; 31(9):1438-46. PubMed ID: 23606458
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty.
    Uvehammer J
    Acta Orthop Scand Suppl; 2001 Feb; 72(299):1-52. PubMed ID: 11381581
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Anteroposterior translation and range of motion after total knee arthroplasty using posterior cruciate ligament-retaining versus posterior cruciate ligament-substituting prostheses.
    Ishii Y; Noguchi H; Sato J; Sakurai T; Toyabe SI
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3536-3542. PubMed ID: 27485124
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does a third condyle TKA restore normal gait kinematics in varus knees? In vivo knee kinematic analysis.
    Bytyqi D; Shabani B; Cheze L; Neyret P; Lustig S
    Arch Orthop Trauma Surg; 2017 Mar; 137(3):409-416. PubMed ID: 28160060
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Is the posterior cruciate ligament necessary for medial pivot knee prostheses with regard to postoperative kinematics?
    Fang CH; Chang CM; Lai YS; Chen WC; Song DY; McClean CJ; Kao HY; Qu TB; Cheng CK
    Knee Surg Sports Traumatol Arthrosc; 2015 Nov; 23(11):3375-82. PubMed ID: 25155052
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new spacer-guided, PCL balancing technique for cruciate-retaining total knee replacement.
    Heesterbeek PJ; Labey L; Wong P; Innocenti B; Wymenga AB
    Knee Surg Sports Traumatol Arthrosc; 2014 Mar; 22(3):650-9. PubMed ID: 24013461
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Femorotibial kinematics and load patterns after total knee arthroplasty: An in vitro comparison of posterior-stabilized versus medial-stabilized design.
    Steinbrück A; Schröder C; Woiczinski M; Fottner A; Pinskerova V; Müller PE; Jansson V
    Clin Biomech (Bristol); 2016 Mar; 33():42-48. PubMed ID: 26945720
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.