BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 24893494)

  • 1. [Beam quality conversion factor].
    Kawachi T; Katayose T
    Igaku Butsuri; 2013; 33(4):186-91. PubMed ID: 24893494
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Consistency in reference radiotherapy dosimetry: resolution of an apparent conundrum when (60)Co is the reference quality for charged-particle and photon beams.
    Andreo P; Wulff J; Burns DT; Palmans H
    Phys Med Biol; 2013 Oct; 58(19):6593-621. PubMed ID: 24018471
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electron beam quality k(Q,Q0) factors for various ionization chambers: a Monte Carlo investigation with PENELOPE.
    Erazo F; Brualla L; Lallena AM
    Phys Med Biol; 2014 Nov; 59(21):6673-91. PubMed ID: 25325343
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Uncertainty of cross calibration-applied beam quality conversion factor for the Japan Society of Medical Physics 12].
    Kinoshita N; Kita A; Takemura A; Nishimoto Y; Adachi T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2014 Sep; 70(9):877-82. PubMed ID: 25242596
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Chamber-quality factors in 60Co for three plane-parallel chambers for the dosimetry of electrons, protons and heavier charged particles: PENELOPE Monte Carlo simulations.
    Panettieri V; Sempau J; Andreo P
    Phys Med Biol; 2008 Nov; 53(21):5917-26. PubMed ID: 18836218
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Investigation of systematic uncertainties in Monte Carlo-calculated beam quality correction factors.
    Wulff J; Heverhagen JT; Zink K; Kawrakow I
    Phys Med Biol; 2010 Aug; 55(16):4481-93. PubMed ID: 20668340
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simplified TRS398 dosimetry protocol for dose determination in high-energy electrons beams.
    Behin-Ain S; Lanzon P
    Phys Med Biol; 2006 May; 51(9):2205-9. PubMed ID: 16625036
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Photon beam quality correction factors for the NE2571A and NE2581A thimble ionization chambers using PENELOPE.
    Erazo F; Lallena AM
    Phys Med; 2016 Jan; 32(1):232-6. PubMed ID: 26602965
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The determination of beam quality correction factors: Monte Carlo simulations and measurements.
    González-Castaño DM; Hartmann GH; Sánchez-Doblado F; Gómez F; Kapsch RP; Pena J; Capote R
    Phys Med Biol; 2009 Aug; 54(15):4723-41. PubMed ID: 19622853
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields.
    Czarnecki D; Zink K
    Phys Med Biol; 2013 Apr; 58(8):2431-44. PubMed ID: 23514734
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of consensus k
    Andreo P; Burns DT; Kapsch RP; McEwen M; Vatnitsky S; Andersen CE; Ballester F; Borbinha J; Delaunay F; Francescon P; Hanlon MD; Mirzakhanian L; Muir B; Ojala J; Oliver CP; Pimpinella M; Pinto M; de Prez LA; Seuntjens J; Sommier L; Teles P; Tikkanen J; Vijande J; Zink K
    Phys Med Biol; 2020 May; 65(9):095011. PubMed ID: 32182598
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Outline of standard dosimetry of absorbed dose to water in external beam radiotherapy].
    Saitoh H
    Igaku Butsuri; 2013; 33(4):171-8. PubMed ID: 24893492
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Experimental determination of beam quality factors, kQ, for two types of Farmer chamber in a 10 MV photon and a 175 MeV proton beam.
    Medin J; Ross CK; Klassen NV; Palmans H; Grusell E; Grindborg JE
    Phys Med Biol; 2006 Mar; 51(6):1503-21. PubMed ID: 16510959
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biological dose calculation with Monte Carlo physics simulation for heavy-ion radiotherapy.
    Kase Y; Kanematsu N; Kanai T; Matsufuji N
    Phys Med Biol; 2006 Dec; 51(24):N467-75. PubMed ID: 17148817
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo calculations of beam quality correction factors kQ for electron dosimetry with a parallel-plate Roos chamber.
    Zink K; Wulff J
    Phys Med Biol; 2008 Mar; 53(6):1595-607. PubMed ID: 18367790
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental investigation of the effect of air cavity size in cylindrical ionization chambers on the measurements in ⁶⁰Co radiotherapy beams.
    Swanpalmer J; Johansson KA
    Phys Med Biol; 2011 Nov; 56(22):7093-107. PubMed ID: 22016264
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Re-evaluation of correction factors of a primary standard graphite calorimeter in 60Co gamma ray beams as a basis for the appointment of the BEV absorbed dose rate to water reference value.
    Baumgartner A; Steurer A; Tiefenböck W; Gabris F; Maringer FJ; Kapsch RP; Stucki G
    Radiat Prot Dosimetry; 2011 Apr; 145(1):3-12. PubMed ID: 21112889
    [TBL] [Abstract][Full Text] [Related]  

  • 19. On the p(dis) correction factor for cylindrical chambers.
    Andreo P
    Phys Med Biol; 2010 Mar; 55(5):L9-16; author reply L17-9. PubMed ID: 20157227
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Non-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy.
    Chofor N; Harder D; Poppe B
    Z Med Phys; 2012 Sep; 22(3):181-96. PubMed ID: 22658451
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.