These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 2490523)

  • 1. Extracorporeal determination of glucose, lactate and potassium with electrochemical biosensors.
    Mascini M; Palleschi G; Moscone D; Bernardi L
    J Pharm Biomed Anal; 1989; 7(12):1377-83. PubMed ID: 2490523
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lactate and glucose electrochemical biosensors for the evaluation of the aerobic and anaerobic threshold in runners.
    Palleschi G; Mascini M; Bernardi L; Zeppilli P
    Med Biol Eng Comput; 1990 May; 28(3):B25-8. PubMed ID: 2376999
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lactate and pyruvate electrochemical biosensors for whole blood in extracorporeal experiments with an endocrine artificial pancreas.
    Mascini M; Mazzei F; Moscone D; Calabrese G; Benedetti MM
    Clin Chem; 1987 Apr; 33(4):591-3. PubMed ID: 3829396
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of miniaturized sensors in clinical and laboratory setting for measuring blood analytes including glucose and lactate.
    Mansouri S
    Ann Biol Clin (Paris); 2003; 61(2):193-8. PubMed ID: 12702474
    [No Abstract]   [Full Text] [Related]  

  • 5. Minimal-Fouling enzyme electrode for continuous flow measurement of whole blood lactate.
    Kyröläinen M; Håkanson H; Mattiasson B; Vadgama P
    Biosens Bioelectron; 1997; 12(11):1073-81. PubMed ID: 9451796
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Long-functioning beta-D-glucose and L-lactate biosensors for continuous flow-through measurements for "fouling"-resistant and selectivity-optimized serum- and hemoanalysis].
    Schindler JG; Schindler MM; Herna K; Pohl M; Guntermann H; Burk B; Reisinger E
    Eur J Clin Chem Clin Biochem; 1994 Aug; 32(8):599-608. PubMed ID: 7819432
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous and simultaneous electrochemical measurements of glucose, lactate, and ascorbate in rat brain following brain ischemia.
    Lin Y; Yu P; Hao J; Wang Y; Ohsaka T; Mao L
    Anal Chem; 2014 Apr; 86(8):3895-901. PubMed ID: 24621127
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Needle enzyme electrodes for biological studies.
    Churchouse SJ; Battersby CM; Mullen WH; Vadgama PM
    Biosensors; 1986; 2(6):325-42. PubMed ID: 3632730
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Novel planar glucose biosensors for continuous monitoring use.
    Ricci F; Moscone D; Tuta CS; Palleschi G; Amine A; Poscia A; Valgimigli F; Messeri D
    Biosens Bioelectron; 2005 Apr; 20(10):1993-2000. PubMed ID: 15741068
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electrochemical assay system with single-use electrode strip for measuring lactate in whole blood.
    Shimojo N; Naka K; Uenoyama H; Hamamoto K; Yoshioka K; Okuda K
    Clin Chem; 1993 Nov; 39(11 Pt 1):2312-4. PubMed ID: 8222226
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lactate biosensors for continuous monitoring.
    Mo JW; Smart W
    Front Biosci; 2004 Sep; 9():3384-91. PubMed ID: 15353365
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metabolic responses to a 90 km running race.
    McKechnie JK; Leary WP; Noakes TD
    S Afr Med J; 1982 Mar; 61(13):482-4. PubMed ID: 7038921
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Enzyme electrodes as practical biosensors.
    Vadgama P
    J Med Eng Technol; 1981 Nov; 5(6):293-8. PubMed ID: 7035672
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of electrochemical sensors for on-line monitoring of ionized calcium, potassium, and glucose in whole blood of living dogs.
    Fogt EJ; Eddy AR; Clemens AH; Fox J; Heath H
    Clin Chem; 1980 Sep; 26(10):1425-9. PubMed ID: 7408171
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Thin-film microbiosensors for glucose-lactate monitoring.
    Jobst G; Moser I; Varahram M; Svasek P; Aschauer E; Trajanoski Z; Wach P; Kotanko P; Skrabal F; Urban G
    Anal Chem; 1996 Sep; 68(18):3173-9. PubMed ID: 8797377
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Flow-through and catheter biosensors with an extended concentration range.
    Laurinavicius VA; Kulys JJ; Gureviciene VV; Simonavicius KJ
    Biomed Biochim Acta; 1989; 48(11-12):905-9. PubMed ID: 2636835
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lactate production and anaerobic work capacity after prolonged exercise.
    Asmussen E; Klausen K; Nielsen LE; Techow OS; Tonder PJ
    Acta Physiol Scand; 1974 Apr; 90(4):731-42. PubMed ID: 4832089
    [No Abstract]   [Full Text] [Related]  

  • 18. Electrochemical-enzymatic analysis of blood glucose and lactate.
    Williams DL; Doig AR; Korosi A
    Anal Chem; 1970 Jan; 42(1):118-21. PubMed ID: 5409504
    [No Abstract]   [Full Text] [Related]  

  • 19. Electrochemical biosensors for medicine and ecology.
    Bogdanovskaya VA; Tarasevich MR
    Biosens Bioelectron; 1996; 11(9):853-61. PubMed ID: 8688163
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vivo biosensors.
    Vadgama P; Desai MA
    Bioprocess Technol; 1991; 15():303-38. PubMed ID: 1367607
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.