These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 24906917)

  • 1. An optimized method for estimating the tidal volume from intracardiac or body surface electrocardiographic signals: implications for estimating minute ventilation.
    Sayadi O; Weiss EH; Merchant FM; Puppala D; Armoundas AA
    Am J Physiol Heart Circ Physiol; 2014 Aug; 307(3):H426-36. PubMed ID: 24906917
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An optimized method for the estimation of the respiratory rate from electrocardiographic signals: implications for estimating minute ventilation.
    Weiss EH; Sayadi O; Ramaswamy P; Merchant FM; Sajja N; Foley L; Laferriere S; Armoundas AA
    Am J Physiol Heart Circ Physiol; 2014 Aug; 307(3):H437-47. PubMed ID: 24858847
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Utility of a smartphone based system (cvrphone) to accurately determine apneic events from electrocardiographic signals.
    Sohn K; Merchant FM; Abohashem S; Kulkarni K; Singh JP; Heist EK; Owen C; Roberts JD; Isselbacher EM; Sana F; Armoundas AA
    PLoS One; 2019; 14(6):e0217217. PubMed ID: 31206522
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel method to capture the onset of dynamic electrocardiographic ischemic changes and its implications to arrhythmia susceptibility.
    Sayadi O; Puppala D; Ishaque N; Doddamani R; Merchant FM; Barrett C; Singh JP; Heist EK; Mela T; Martínez JP; Laguna P; Armoundas AA
    J Am Heart Assoc; 2014 Sep; 3(5):e001055. PubMed ID: 25187521
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Utility of a Smartphone-Based System (cvrPhone) in Estimating Minute Ventilation from Electrocardiographic Signals.
    Kulkarni K; Awasthi N; Roberts JD; Armoundas AA
    Telemed J E Health; 2021 Dec; 27(12):1433-1439. PubMed ID: 33729001
    [No Abstract]   [Full Text] [Related]  

  • 6. Estimation of Tidal Volume Using Load Cells on a Hospital Bed.
    Jung H; Kimball JP; Receveur T; Gazi AH; Agdeppa ED; Inan OT
    IEEE J Biomed Health Inform; 2022 Jul; 26(7):3330-3341. PubMed ID: 34995200
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel lead configuration for optimal spatio-temporal detection of intracardiac repolarization alternans.
    Weiss EH; Merchant FM; d'Avila A; Foley L; Reddy VY; Singh JP; Mela T; Ruskin JN; Armoundas AA
    Circ Arrhythm Electrophysiol; 2011 Jun; 4(3):407-17. PubMed ID: 21430127
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous LV and RV volumes by conductance catheter: effects of lung insufflation on parallel conductance.
    Szwarc RS; Ball HA
    Am J Physiol; 1998 Aug; 275(2):H653-61. PubMed ID: 9683455
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intracardiac electrode detection of early or subendocardial ischemia.
    Siegel S; Brodman R; Fisher J; Matos J; Furman S
    Pacing Clin Electrophysiol; 1982 Nov; 5(6):892-902. PubMed ID: 6184692
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Non-Contact Respiratory Measurement Using a Depth Camera for Elderly People.
    Imano W; Kameyama K; Hollingdal M; Refsgaard J; Larsen K; Topp C; Kronborg SH; Gade JD; Dinesen B
    Sensors (Basel); 2020 Dec; 20(23):. PubMed ID: 33287154
    [TBL] [Abstract][Full Text] [Related]  

  • 11. How much lung ventilation is obtained with only chest-compression CPR?
    Geddes LA; Rundell A; Otlewski M; Pargett M
    Cardiovasc Eng; 2008 Sep; 8(3):145-8. PubMed ID: 18581233
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel ECG-based algorithm to determine right ventricular lead placement in permanent pacemaker patients (RVpace study).
    Zajac D; Farkowski MM; Kowalik I; Jankowska A; Firek B; Szwed H; Pytkowski M
    J Cardiovasc Electrophysiol; 2019 Oct; 30(10):2034-2040. PubMed ID: 31402513
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of 7 Different Sensors for Detecting Low Respiratory Rates Using a Single Breath Detection Algorithm in Nonintubated, Sedated Volunteers.
    Ermer S; Brewer L; Orr J; Egan TD; Johnson K
    Anesth Analg; 2019 Aug; 129(2):399-408. PubMed ID: 30234539
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tailoring device settings in cardiac resynchronization therapy using electrograms from pacing electrodes.
    Engels EB; Mafi-Rad M; Hermans BJM; Aranda A; van Stipdonk AMW; Rienstra M; Scheerder COS; Maass AH; Prinzen FW; Vernooy K
    Europace; 2018 Jul; 20(7):1146-1153. PubMed ID: 29106563
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tidal volume and minute ventilation parameters derived from pacemaker impedance measurements can predict experimental heart failure development.
    Lefkov S; de Voir C; Müssig D; Tkebuchava T; Lian J; Orlov MV
    Pacing Clin Electrophysiol; 2014 Feb; 37(2):215-24. PubMed ID: 24033775
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Can body surface microvolt T-wave alternans distinguish concordant and discordant intracardiac alternans?
    Floré V; Claus P; Symons R; Smith GL; Sipido KR; Willems R
    Pacing Clin Electrophysiol; 2013 Aug; 36(8):1007-16. PubMed ID: 23614703
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electrocardiogram-Derived Tidal Volume During Treadmill Stress Test.
    Milagro J; Hernando D; Lazaro J; Casajus JA; Garatachea N; Gil E; Bailon R
    IEEE Trans Biomed Eng; 2020 Jan; 67(1):193-202. PubMed ID: 30990416
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Evaluation of a Noninvasive Respiratory Volume Monitor in Pediatric Patients Undergoing General Anesthesia.
    Gomez-Morad AD; Cravero JP; Harvey BC; Bernier R; Halpin E; Walsh B; Nasr VG
    Anesth Analg; 2017 Dec; 125(6):1913-1919. PubMed ID: 28759491
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Construction of intracardiac vectorcardiogram from implantable cardioverter-defibrillator intracardiac electrograms.
    Ghafoori E; Kabir MM; Cao J; Shvilkin A; Tereshchenko LG
    J Electrocardiol; 2015; 48(4):669-71. PubMed ID: 25987408
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative investigations of algorithms for the detection of breaths in newborns with disturbed respiratory signals.
    Schmidt M; Foitzik B; Wauer RR; Winkler F; Schmalisch G
    Comput Biomed Res; 1998 Dec; 31(6):413-25. PubMed ID: 9843627
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.