These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

63 related articles for article (PubMed ID: 24907129)

  • 1. In vivo application of an optical segment tracking approach for bone loading regimes recording in humans: a reliability study.
    Yang PF; Sanno M; Ganse B; Koy T; Brüggemann GP; Müller LP; Rittweger J
    Med Eng Phys; 2014 Aug; 36(8):1041-6. PubMed ID: 24907129
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo measurements of human bone deformation using optical segment tracking: surgical approach and validation in a three-point bending test.
    Ganse B; Yang PF; Brüggemann GP; Müller LP; Rittweger J; Koy T
    J Musculoskelet Neuronal Interact; 2014 Mar; 14(1):95-103. PubMed ID: 24583544
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tibia segment deformation in response to simulated muscle forces: a cadaveric study with a novel optical segment tracking (OST) approach.
    Yang PF; Engel K; Sanno M; Dargel J; Wegmann K; Brüggemann GP; Rittweger J
    J Musculoskelet Neuronal Interact; 2014 Sep; 14(3):267-75. PubMed ID: 25198221
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On the relationship between tibia torsional deformation and regional muscle contractions in habitual human exercises in vivo.
    Yang PF; Kriechbaumer A; Albracht K; Sanno M; Ganse B; Koy T; Shang P; Brüggemann GP; Müller LP; Rittweger J
    J Biomech; 2015 Feb; 48(3):456-64. PubMed ID: 25543279
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Torsion and antero-posterior bending in the in vivo human tibia loading regimes during walking and running.
    Yang PF; Sanno M; Ganse B; Koy T; Brüggemann GP; Müller LP; Rittweger J
    PLoS One; 2014; 9(4):e94525. PubMed ID: 24732724
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Motion of the fibula relative to the tibia and its alterations with syndesmosis screws: A cadaver study.
    Huber T; Schmoelz W; Bölderl A
    Foot Ankle Surg; 2012 Sep; 18(3):203-9. PubMed ID: 22857964
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Syndesmosis fixation using dual 3.5 mm and 4.5 mm screws with tricortical and quadricortical purchase: a biomechanical study.
    Markolf KL; Jackson SR; McAllister DR
    Foot Ankle Int; 2013 May; 34(5):734-9. PubMed ID: 23405026
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study.
    Gueorguiev B; Ockert B; Schwieger K; Wähnert D; Lawson-Smith M; Windolf M; Stoffel K
    J Orthop Trauma; 2011 Jun; 25(6):340-6. PubMed ID: 21577069
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.
    Weninger P; Schueller M; Jamek M; Stanzl-Tschegg S; Redl H; Tschegg EK
    Clin Biomech (Bristol, Avon); 2009 May; 24(4):379-84. PubMed ID: 19231049
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comment on: ''In vivo measurements of human bone deformation using optical segment tracking: surgical approach and validation in a three-point bending test''.
    Liu Y; Li H
    J Musculoskelet Neuronal Interact; 2014 Jun; 14(2):244. PubMed ID: 24879029
    [No Abstract]   [Full Text] [Related]  

  • 11. [Testing System for Biomechanical Properties of Bone].
    Guo Z; Guo Z; Liang X
    Zhongguo Yi Liao Qi Xie Za Zhi; 2018 Feb; 42(2):84-87. PubMed ID: 29845804
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An MRI-based method to align the compressive loading axis for human cadaveric knees.
    Martin KJ; Neu CP; Hull ML
    J Biomech Eng; 2007 Dec; 129(6):855-62. PubMed ID: 18067389
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reduction of pullout strength caused by reinsertion of 3.5-mm cortical screws.
    Matityahu A; Hurschler C; Badenhop M; Stukenborg-Colsman C; Waizy H; Wentz B; Marmor M; Krettek C
    J Orthop Trauma; 2013 Mar; 27(3):170-6. PubMed ID: 22534691
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Experimental deformation in a bone fixation plate: measurement using holographic interferometry].
    Kojima A
    Nihon Seikeigeka Gakkai Zasshi; 1995 Sep; 69(9):685-98. PubMed ID: 8530884
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical analysis of pedicle screws in osteoporotic bone with bioactive cement augmentation using simulated in vivo multicomponent loading.
    Choma TJ; Frevert WF; Carson WL; Waters NP; Pfeiffer FM
    Spine (Phila Pa 1976); 2011 Mar; 36(6):454-62. PubMed ID: 20881517
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The biomechanical study of craniovertebral junction fixation with posterior transarticular screw].
    Yan WJ; Cai B; Chen Y; Yuan W; Li JS; Jia LS; Yang GB; Zeng WM
    Zhonghua Yi Xue Za Zhi; 2006 Apr; 86(13):872-5. PubMed ID: 16759510
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the performance of a motion capture system for small displacement recording and a discussion for its application potential in bone deformation in vivo measurements.
    Yang PF; Sanno M; Brüggemann GP; Rittweger J
    Proc Inst Mech Eng H; 2012 Nov; 226(11):838-47. PubMed ID: 23185954
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does a tensioning device pinned to the tibia improve knee anterior-posterior load-displacement compared to manual tensioning of the graft following anterior cruciate ligament reconstruction? A cadaveric study of two tibial fixation devices.
    Thompson DM; Hull ML; Howell SM
    J Orthop Res; 2006 Sep; 24(9):1832-41. PubMed ID: 16865723
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Proximal half angle of the screw thread is a critical design variable affecting the pull-out strength of cancellous bone screws.
    Wang Y; Mori R; Ozoe N; Nakai T; Uchio Y
    Clin Biomech (Bristol, Avon); 2009 Nov; 24(9):781-5. PubMed ID: 19699567
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Micromotion at the fracture site after tibial nailing with four unreamed small-diameter nails--a biomechanical study using a distal tibia fracture model.
    Schüller M; Weninger P; Tschegg E; Jamek M; Redl H; Stanzl-Tschegg S
    J Trauma; 2009 May; 66(5):1391-7. PubMed ID: 19430244
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.