These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
1390 related articles for article (PubMed ID: 24912033)
21. An electrochemical immunosensor for brain natriuretic peptide prepared with screen-printed carbon electrodes nanostructured with gold nanoparticles grafted through aryl diazonium salt chemistry. Serafín V; Torrente-Rodríguez RM; González-Cortés A; García de Frutos P; Sabaté M; Campuzano S; Yáñez-Sedeño P; Pingarrón JM Talanta; 2018 Mar; 179():131-138. PubMed ID: 29310212 [TBL] [Abstract][Full Text] [Related]
22. A microfluidic device based on a screen-printed carbon electrode with electrodeposited gold nanoparticles for the detection of IgG anti-Trypanosoma cruzi antibodies. Pereira SV; Bertolino FA; Fernández-Baldo MA; Messina GA; Salinas E; Sanz MI; Raba J Analyst; 2011 Nov; 136(22):4745-51. PubMed ID: 21984978 [TBL] [Abstract][Full Text] [Related]
23. Aptamer-based highly sensitive electrochemical detection of thrombin via the amplification of graphene. Jiang L; Yuan R; Chai Y; Yuan Y; Bai L; Wang Y Analyst; 2012 May; 137(10):2415-20. PubMed ID: 22489284 [TBL] [Abstract][Full Text] [Related]
24. Aptamer/thrombin/aptamer-AuNPs sandwich enhanced surface plasmon resonance sensor for the detection of subnanomolar thrombin. Bai Y; Feng F; Zhao L; Wang C; Wang H; Tian M; Qin J; Duan Y; He X Biosens Bioelectron; 2013 Sep; 47():265-70. PubMed ID: 23584389 [TBL] [Abstract][Full Text] [Related]
25. A disposable electrochemical immunosensor based on carbon screen-printed electrodes for the detection of prostate specific antigen. Yan M; Zang D; Ge S; Ge L; Yu J Biosens Bioelectron; 2012; 38(1):355-61. PubMed ID: 22770827 [TBL] [Abstract][Full Text] [Related]
26. Label-free electrochemical detection of human α-thrombin in blood serum using ferrocene-coated gold nanoparticles. Kwon D; Jeong H; Chung BH Biosens Bioelectron; 2011 Oct; 28(1):454-8. PubMed ID: 21802275 [TBL] [Abstract][Full Text] [Related]
27. Au-nanoparticles as an electrochemical sensing platform for aptamer-thrombin interaction. Suprun E; Shumyantseva V; Bulko T; Rachmetova S; Rad'ko S; Bodoev N; Archakov A Biosens Bioelectron; 2008 Dec; 24(4):831-6. PubMed ID: 18755579 [TBL] [Abstract][Full Text] [Related]
28. Ultrasensitive electrochemical immunosensor for PSA biomarker detection in prostate cancer cells using gold nanoparticles/PAMAM dendrimer loaded with enzyme linked aptamer as integrated triple signal amplification strategy. Kavosi B; Salimi A; Hallaj R; Moradi F Biosens Bioelectron; 2015 Dec; 74():915-23. PubMed ID: 26257183 [TBL] [Abstract][Full Text] [Related]
29. Sensitive Impedimetric Immunoassay of Japanese Encephalitis Virus Based on Enzyme Biocatalyzed Precipitation on a Gold Nanoparticle-modified Screen-printed Carbon Electrode. Geng X; Zhang F; Gao Q; Lei Y Anal Sci; 2016; 32(10):1105-1109. PubMed ID: 27725612 [TBL] [Abstract][Full Text] [Related]
30. Visual detection of thrombin using a strip biosensor through aptamer-cleavage reaction with enzyme catalytic amplification. Qin C; Wen W; Zhang X; Gu H; Wang S Analyst; 2015 Nov; 140(22):7710-7. PubMed ID: 26451394 [TBL] [Abstract][Full Text] [Related]
31. Impedimetric aptasensor with femtomolar sensitivity based on the enlargement of surface-charged gold nanoparticles. Deng C; Chen J; Nie Z; Wang M; Chu X; Chen X; Xiao X; Lei C; Yao S Anal Chem; 2009 Jan; 81(2):739-45. PubMed ID: 19072036 [TBL] [Abstract][Full Text] [Related]
32. A novel sandwich-type electrochemical aptasensor based on GR-3D Au and aptamer-AuNPs-HRP for sensitive detection of oxytetracycline. Liu S; Wang Y; Xu W; Leng X; Wang H; Guo Y; Huang J Biosens Bioelectron; 2017 Feb; 88():181-187. PubMed ID: 27544787 [TBL] [Abstract][Full Text] [Related]
33. Label-free electrochemical aptasensor for sensitive thrombin detection using layer-by-layer self-assembled multilayers with toluidine blue-graphene composites and gold nanoparticles. Xie S; Yuan R; Chai Y; Bai L; Yuan Y; Wang Y Talanta; 2012 Aug; 98():7-13. PubMed ID: 22939121 [TBL] [Abstract][Full Text] [Related]
34. An off-on-off electrochemiluminescence approach for ultrasensitive detection of thrombin. Deng L; Du Y; Xu JJ; Chen HY Biosens Bioelectron; 2014 Sep; 59():58-63. PubMed ID: 24699694 [TBL] [Abstract][Full Text] [Related]
35. A sensitive gold nanoparticles sensing platform based on resonance energy transfer for chemiluminescence light on detection of biomolecules. Qin G; Zhao S; Huang Y; Jiang J; Liu YM Biosens Bioelectron; 2013 Aug; 46():119-23. PubMed ID: 23524140 [TBL] [Abstract][Full Text] [Related]
36. A simple and sensitive impedimetric aptasensor for the detection of tumor markers based on gold nanoparticles signal amplification. Liu X; Qin Y; Deng C; Xiang J; Li Y Talanta; 2015 Jan; 132():150-4. PubMed ID: 25476292 [TBL] [Abstract][Full Text] [Related]
37. Simple and sensitive aptasensor based on quantum dot-coated silica nanospheres and the gold screen-printed electrode. Li Y; Deng L; Deng C; Nie Z; Yang M; Si S Talanta; 2012 Sep; 99():637-42. PubMed ID: 22967605 [TBL] [Abstract][Full Text] [Related]
38. A chronocoulometric aptasensor based on gold nanoparticles as a signal amplification strategy for detection of thrombin. Jiao XX; Chen JR; Zhang XY; Luo HQ; Li NB Anal Biochem; 2013 Oct; 441(2):95-100. PubMed ID: 23896460 [TBL] [Abstract][Full Text] [Related]
39. Novel electrochemical aptamer biosensor based on an enzyme-gold nanoparticle dual label for the ultrasensitive detection of epithelial tumour marker MUC1. Hu R; Wen W; Wang Q; Xiong H; Zhang X; Gu H; Wang S Biosens Bioelectron; 2014 Mar; 53():384-9. PubMed ID: 24189297 [TBL] [Abstract][Full Text] [Related]
40. Label-free aptamer biosensor for thrombin detection based on functionalized graphene nanocomposites. Wang Q; Zhou Z; Zhai Y; Zhang L; Hong W; Zhang Z; Dong S Talanta; 2015 Aug; 141():247-52. PubMed ID: 25966410 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]