These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
280 related articles for article (PubMed ID: 24915540)
1. A multidisciplinary, multifaceted improvement initiative to eliminate mislabelled laboratory specimens at a large tertiary care hospital. Seferian EG; Jamal S; Clark K; Cirricione M; Burnes-Bolton L; Amin M; Romanoff N; Klapper E BMJ Qual Saf; 2014 Aug; 23(8):690-7. PubMed ID: 24915540 [TBL] [Abstract][Full Text] [Related]
2. Surgical specimen identification errors: a new measure of quality in surgical care. Makary MA; Epstein J; Pronovost PJ; Millman EA; Hartmann EC; Freischlag JA Surgery; 2007 Apr; 141(4):450-5. PubMed ID: 17383521 [TBL] [Abstract][Full Text] [Related]
3. A quality initiative to decrease pathology specimen-labeling errors using radiofrequency identification in a high-volume endoscopy center. Francis DL; Prabhakar S; Sanderson SO Am J Gastroenterol; 2009 Apr; 104(4):972-5. PubMed ID: 19259073 [TBL] [Abstract][Full Text] [Related]
4. Reducing specimen identification errors. Rees S; Stevens L; Mikelsons D; Quam E; Darcy T J Nurs Care Qual; 2012; 27(3):253-7. PubMed ID: 22446504 [TBL] [Abstract][Full Text] [Related]
5. Specimen rejection in laboratory medicine: Necessary for patient safety? Dikmen ZG; Pinar A; Akbiyik F Biochem Med (Zagreb); 2015; 25(3):377-85. PubMed ID: 26527231 [TBL] [Abstract][Full Text] [Related]
6. Patient safety in the clinical laboratory: a longitudinal analysis of specimen identification errors. Wagar EA; Tamashiro L; Yasin B; Hilborne L; Bruckner DA Arch Pathol Lab Med; 2006 Nov; 130(11):1662-8. PubMed ID: 17076528 [TBL] [Abstract][Full Text] [Related]
7. [Patient identification errors and biological samples in the analytical process: Is it possible to improve patient safety?]. Cuadrado-Cenzual MA; García Briñón M; de Gracia Hills Y; González Estecha M; Collado Yurrita L; de Pedro Moro JA; Fernández Pérez C; Arroyo Fernández M Rev Calid Asist; 2015; 30(6):310-8. PubMed ID: 26542791 [TBL] [Abstract][Full Text] [Related]
9. Clinical consequences of specimen rejection: a College of American Pathologists Q-Probes analysis of 78 clinical laboratories. Karcher DS; Lehman CM Arch Pathol Lab Med; 2014 Aug; 138(8):1003-8. PubMed ID: 25076290 [TBL] [Abstract][Full Text] [Related]
10. Reduction in Hospital-Wide Clinical Laboratory Specimen Identification Errors following Process Interventions: A 10-Year Retrospective Observational Study. Ning HC; Lin CN; Chiu DT; Chang YT; Wen CN; Peng SY; Chu TL; Yu HM; Wu TL PLoS One; 2016; 11(8):e0160821. PubMed ID: 27494020 [TBL] [Abstract][Full Text] [Related]
11. Reducing Surgical Specimen Errors Through Multidisciplinary Quality Improvement. Holstine JB; Samora JB Jt Comm J Qual Patient Saf; 2021 Sep; 47(9):563-571. PubMed ID: 34045158 [TBL] [Abstract][Full Text] [Related]
12. Preanalytical error occurrence rate in clinical chemistry laboratory of a public hospital in India. Singla P; Parkash AA; Bhattacharjee J Clin Lab; 2011; 57(9-10):749-52. PubMed ID: 22029191 [TBL] [Abstract][Full Text] [Related]
13. Standardized patient identification and specimen labeling: a retrospective analysis on improving patient safety. Kim JK; Dotson B; Thomas S; Nelson KC J Am Acad Dermatol; 2013 Jan; 68(1):53-6. PubMed ID: 22841126 [TBL] [Abstract][Full Text] [Related]
14. Decreasing mislabeled laboratory specimens using barcode technology and bedside printers. Brown JE; Smith N; Sherfy BR J Nurs Care Qual; 2011; 26(1):13-21. PubMed ID: 20512048 [TBL] [Abstract][Full Text] [Related]
15. Identification errors in pathology and laboratory medicine. Valenstein PN; Sirota RL Clin Lab Med; 2004 Dec; 24(4):979-96, vii. PubMed ID: 15555752 [TBL] [Abstract][Full Text] [Related]
16. Reducing preanalytical laboratory sample errors through educational and technological interventions. Lillo R; Salinas M; Lopez-Garrigos M; Naranjo-Santana Y; Gutiérrez M; Marín MD; Miralles M; Uris J Clin Lab; 2012; 58(9-10):911-7. PubMed ID: 23163106 [TBL] [Abstract][Full Text] [Related]
17. Specimen labeling errors in surgical pathology: an 18-month experience. Layfield LJ; Anderson GM Am J Clin Pathol; 2010 Sep; 134(3):466-70. PubMed ID: 20716804 [TBL] [Abstract][Full Text] [Related]
18. Getting It Right for Patient Safety: Specimen Collection Process Improvement From Operating Room to Pathology. D'Angelo R; Mejabi O Am J Clin Pathol; 2016 Jul; 146(1):8-17. PubMed ID: 27402606 [TBL] [Abstract][Full Text] [Related]
19. Mislabeling of cases, specimens, blocks, and slides: a college of american pathologists study of 136 institutions. Nakhleh RE; Idowu MO; Souers RJ; Meier FA; Bekeris LG Arch Pathol Lab Med; 2011 Aug; 135(8):969-74. PubMed ID: 21809987 [TBL] [Abstract][Full Text] [Related]