BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

262 related articles for article (PubMed ID: 24915801)

  • 21. Multicenter evaluation of the cobas m 511 integrated hematology analyzer.
    Bruegel M; George TI; Feng B; Allen TR; Bracco D; Zahniser DJ; Russcher H
    Int J Lab Hematol; 2018 Dec; 40(6):672-682. PubMed ID: 30030894
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Utility of microsemi LC-667CRP in point of care testing system for acute inflammatory disease].
    Inaba T; Yuasa S; Taniguchi H; Nakashima K; Nagaoka H; Fujita N
    Rinsho Byori; 2010 Jul; 58(7):664-9. PubMed ID: 20715509
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of hematological values obtained with reference automated hematology analyzers of six manufacturers.
    Takubo T; Tatsumi N; Satoh N; Matsuno K; Fujimoto K; Soga M; Yamagami Y; Akiba S; Sudoh T; Miyazaki M
    Southeast Asian J Trop Med Public Health; 2002; 33 Suppl 2():62-7. PubMed ID: 12755270
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Current status and proposal of a guideline for manual slide review of automated complete blood cell count and white blood cell differential].
    Woo HY; Shin SY; Park H; Kim YJ; Kim HJ; Lee YK; Chae SL; Chang YH; Choi JR; Han K; Cho SR; Kwon KC
    Korean J Lab Med; 2010 Dec; 30(6):559-66. PubMed ID: 21157139
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Performance evaluation of the Sysmex pocH-100i automated hematology analyzer.
    Whisler S; Dahlgren C
    Lab Hematol; 2005; 11(2):107-17. PubMed ID: 16024334
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Performance Evaluation of the Mindray BC 6800 Hematology Analyzer and Flag Comparison with the XE-2100 and Manual Microscopy.
    Xiang D; Yue J; Sha C; Ren S; Li M; Wang C
    Clin Lab; 2019 Apr; 65(4):. PubMed ID: 30969092
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Performance Evaluation of a New Generation of Automated Analyzer for Pleural and Peritoneal Fluids Cytology.
    Bottini PV; Garlipp CR; Nogueira BF; Pompeo DB; Souza MI
    Clin Lab; 2018 Oct; 64(10):1783-1786. PubMed ID: 30336515
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Analytic performance of the PENTRA 80 automated blood cell analyzer for the evaluation of normal and pathologic WBCs.
    Arroyo ME; Tabernero MD; García-Marcos MA; Orfao A
    Am J Clin Pathol; 2005 Feb; 123(2):206-14. PubMed ID: 15842044
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation of the impedance analyzer PocH-100iV Diff for analysis of canine and feline blood.
    Bauer NB; Nakagawa J; Dunker C; Failing K; Moritz A
    Vet Clin Pathol; 2012 Jun; 41(2):194-206. PubMed ID: 22324888
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Performance evaluation of Sysmex XN hematology analyzer in umbilical cord blood: a comparison study with Sysmex XE-2100.
    Kim H; Hur M; Choi SG; Moon HW; Yun YM; Hwang HS; Kwon HS; Sohn IS
    Clin Chem Lab Med; 2014 Dec; 52(12):1771-9. PubMed ID: 24978899
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Performance evaluation of Abbott CELL-DYN Ruby for routine use.
    Lehto T; Hedberg P
    Int J Lab Hematol; 2008 Oct; 30(5):400-7. PubMed ID: 19046315
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Laboratory evaluation of the Sysmex SE-9500 automated haematology analyser.
    Peng L; Gao X; Jiang H; Peng Z; Su J
    Clin Lab Haematol; 2001 Aug; 23(4):237-42. PubMed ID: 11683784
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Abnormal neutrophil scattergram obtained using Pentra MS CRP in the patients with myelodysplastic syndrome showing dysgranulopoiesis.
    Inaba T; Ishizuka K; Yuasa S; Mishima N; Ogura K; Saito K; Kohno T; Fujitomo Y; Nakanishi M; Fujita N
    Int J Lab Hematol; 2016 Feb; 38(1):27-33. PubMed ID: 26333345
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Validation of the Celltac alpha automated hematology analyzer for canine and feline blood samples.
    McDaniel BJ; Hirschberger J; Weber K
    Vet Clin Pathol; 2013 Mar; 42(1):11-8. PubMed ID: 23278503
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Performance evaluation of the digital cell imaging analyzer DI-60 integrated into the fully automated Sysmex XN hematology analyzer system.
    Tabe Y; Yamamoto T; Maenou I; Nakai R; Idei M; Horii T; Miida T; Ohsaka A
    Clin Chem Lab Med; 2015 Feb; 53(2):281-9. PubMed ID: 25153399
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The international consensus group for hematology review: suggested criteria for action following automated CBC and WBC differential analysis.
    Barnes PW; McFadden SL; Machin SJ; Simson E;
    Lab Hematol; 2005; 11(2):83-90. PubMed ID: 16024331
    [TBL] [Abstract][Full Text] [Related]  

  • 37. HemoScreen hematology analyzer compared to Sysmex XN for complete blood count, white blood cell differential, and detection of leukocyte abnormalities.
    Linko-Parvinen AM; Keränen K; Kurvinen K; Tienhaara A
    EJHaem; 2022 Nov; 3(4):1126-1134. PubMed ID: 36467845
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A Comparison of Mindray BC-6800, Sysmex XN-2000, and Beckman Coulter LH750 Automated Hematology Analyzers: A Pediatric Study.
    Ciepiela O; Kotuła I; Kierat S; Sieczkowska S; Podsiadłowska A; Jenczelewska A; Księżarczyk K; Demkow U
    J Clin Lab Anal; 2016 Nov; 30(6):1128-1134. PubMed ID: 27184780
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Optimization of laboratory workflow in clinical hematology laboratory with reduced manual slide review: comparison between Sysmex XE-2100 and ABX Pentra DX120.
    Hur M; Cho JH; Kim H; Hong MH; Moon HW; Yun YM; Kim JQ
    Int J Lab Hematol; 2011 Aug; 33(4):434-40. PubMed ID: 21418541
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Multicenter performance evaluation of the Abbott Alinity hq hematology analyzer.
    Slim CL; Wevers BA; Demmers MWHJ; Lakos G; Hoffmann JJML; Adriaansen HJ; Kooren JA; Storm H
    Clin Chem Lab Med; 2019 Nov; 57(12):1988-1998. PubMed ID: 31339851
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.