These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 24922220)

  • 1. Design of resonant cavity structure for efficient high-temperature operation of single-photon avalanche photodiodes.
    Zavvari M; Abedi K; Karimi M
    Appl Opt; 2014 May; 53(15):3311-7. PubMed ID: 24922220
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantum dot infrared photodetector with gated-mode design for mid-IR single photon detection.
    Zavvari M; Ahmadi V
    Appl Opt; 2013 Nov; 52(32):7675-81. PubMed ID: 24216724
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 1550 nm InGaAs/InAlAs single photon avalanche diode at room temperature.
    Meng X; Tan CH; Dimler S; David JP; Ng JS
    Opt Express; 2014 Sep; 22(19):22608-15. PubMed ID: 25321730
    [TBL] [Abstract][Full Text] [Related]  

  • 4. InGaAs/InAlAs single photon avalanche diode for 1550 nm photons.
    Meng X; Xie S; Zhou X; Calandri N; Sanzaro M; Tosi A; Tan CH; Ng JS
    R Soc Open Sci; 2016 Mar; 3(3):150584. PubMed ID: 27069647
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radiometric temperature measurement with Si and InGaAs single-photon avalanche photodiode.
    Wu JY; Lu PK; Hsiao YJ; Lin SD
    Opt Lett; 2014 Oct; 39(19):5515-8. PubMed ID: 25360916
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-performance InGaAs/InAlAs single-photon avalanche diode with a triple-mesa structure for near-infrared photon detection.
    Zhang J; Wang H; Zhang G; Hua Tan K; Wicaksono S; Xu H; Wang C; Chen Y; Liang Y; Lim CCW; Yoon SF; Gong X
    Opt Lett; 2021 Jun; 46(11):2670-2673. PubMed ID: 34061084
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A CdSe quantum dot based resonant cavity light-emitting diode showing single line emission up to 90 K.
    Gust A; Kruse C; Otte K; Kalden J; Meeser T; Sebald K; Gutowski J; Hommel D
    Nanotechnology; 2009 Jan; 20(1):015401. PubMed ID: 19417251
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of single photon detection in avalanche photodetectors with multi-gain-stage multiplication region.
    Hosseinzadeh A; Zavvari M
    Appl Opt; 2017 Feb; 56(6):1631-1636. PubMed ID: 28234369
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design of wafer-bonded structures for near room temperature Geiger-mode operation of germanium on silicon single-photon avalanche photodiode.
    Ke S; Lin S; Mao D; Ye Y; Ji X; Huang W; Li C; Chen S
    Appl Opt; 2017 Jun; 56(16):4646-4653. PubMed ID: 29047596
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Selecting detection wavelength of resonant cavity-enhanced photodetectors by guided-mode resonance reflectors.
    Lai KW; Lee YS; Fu YJ; Lin SD
    Opt Express; 2012 Feb; 20(4):3572-9. PubMed ID: 22418117
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design considerations of high-performance InGaAs/InP single-photon avalanche diodes for quantum key distribution.
    Ma J; Bai B; Wang LJ; Tong CZ; Jin G; Zhang J; Pan JW
    Appl Opt; 2016 Sep; 55(27):7497-502. PubMed ID: 27661574
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance of InGaAs/InP Avalanche Photodiodes as Gated-Mode Photon Counters.
    Ribordy G; Gautier JD; Zbinden H; Gisin N
    Appl Opt; 1998 Apr; 37(12):2272-7. PubMed ID: 18273153
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Single-Photon Avalanche Diode with Enhanced NIR-Sensitivity for Automotive LIDAR Systems.
    Takai I; Matsubara H; Soga M; Ohta M; Ogawa M; Yamashita T
    Sensors (Basel); 2016 Mar; 16(4):459. PubMed ID: 27043569
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Photon-Trapping Microstructure for InGaAs/Si Avalanche Photodiodes Operating at 1.31 μm.
    Zhang H; Tian Y; Li Q; Ding W; Yu X; Lin Z; Feng X; Zhao Y
    Sensors (Basel); 2022 Oct; 22(20):. PubMed ID: 36298075
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Theoretical Analysis of InGaAs/InAlAs Single-Photon Avalanche Photodiodes.
    Cao S; Zhao Y; Feng S; Zuo Y; Zhang L; Cheng B; Li C
    Nanoscale Res Lett; 2019 Jan; 14(1):3. PubMed ID: 30607636
    [TBL] [Abstract][Full Text] [Related]  

  • 16. InGaAs-GaAs Nanowire Avalanche Photodiodes Toward Single-Photon Detection in Free-Running Mode.
    Farrell AC; Meng X; Ren D; Kim H; Senanayake P; Hsieh NY; Rong Z; Chang TY; Azizur-Rahman KM; Huffaker DL
    Nano Lett; 2019 Jan; 19(1):582-590. PubMed ID: 30517782
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of a novel avalanche photodiode for single photon detection in VIS-NIR range.
    Stipcević M; Skenderović H; Gracin D
    Opt Express; 2010 Aug; 18(16):17448-59. PubMed ID: 20721130
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Weak avalanche discrimination for gated-mode single-photon avalanche photodiodes.
    Cho SB; Kang SK
    Opt Express; 2011 Sep; 19(19):18510-5. PubMed ID: 21935220
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Gaussian pulse gated InGaAs/InP avalanche photodiode for single photon detection.
    Zhang Y; Zhang X; Wang S
    Opt Lett; 2013 Mar; 38(5):606-8. PubMed ID: 23455238
    [TBL] [Abstract][Full Text] [Related]  

  • 20. InGaAs/InP Avalanche Photodiode for Single Photon Detection with Zinc Diffusion Process Using Metal Organic Chemical Vapor Deposition.
    Lee IJ; Lee MS; Kim MS; Jun DH; Jeong HY; Kim S; Han SW; Moon S
    J Nanosci Nanotechnol; 2016 May; 16(5):5155-8. PubMed ID: 27483891
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.