BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

269 related articles for article (PubMed ID: 24924271)

  • 21. Clinical comparison of the Welch Allyn SureSight handheld autorefractor versus cycloplegic autorefraction and retinoscopic refraction.
    Iuorno JD; Grant WD; Noël LP
    J AAPOS; 2004 Apr; 8(2):123-7. PubMed ID: 15088044
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Accomodative tone in children under general anesthesia.
    Salchow DJ; Marcus I; Golembeski TJ; Wang X; Li F
    Am J Ophthalmol; 2013 Nov; 156(5):1034-1039.e2. PubMed ID: 23972304
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of the new self-contained darkroom refractive screener versus table-top autorefractor and cycloplegia retinoscopy in detecting refractive error.
    Wei X; Li L; Jiang L; Lu H; Huang H; Zhong D; Pan L; Wei D; Han Y; Lin H; Chen Q
    BMC Ophthalmol; 2023 Nov; 23(1):487. PubMed ID: 38012552
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Clinical evaluation of refraction using a handheld wavefront autorefractor in young and adult patients.
    Schimitzek T; Wesemann W
    J Cataract Refract Surg; 2002 Sep; 28(9):1655-66. PubMed ID: 12231328
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of cycloplegic refraction between Grand Seiko autorefractor and Retinomax autorefractor in the Vision in Preschoolers-Hyperopia in Preschoolers (VIP-HIP) Study.
    Ying GS; Maguire MG; Kulp MT; Ciner E; Moore B; Pistilli M; Candy R;
    J AAPOS; 2017 Jun; 21(3):219-223.e3. PubMed ID: 28528993
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of the SVOne Handheld Autorefractor in a Pediatric Population.
    Rosenfield M; Ciuffreda KJ
    Optom Vis Sci; 2017 Feb; 94(2):159-165. PubMed ID: 27668640
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of retinoscopy results with and without 1% cyclopentolate in school-aged children.
    Doherty SE; Doyle LA; McCullough SJ; Saunders KJ
    Ophthalmic Physiol Opt; 2019 Jul; 39(4):272-281. PubMed ID: 31236978
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of the SVOne: A Handheld, Smartphone-Based Autorefractor.
    Ciuffreda KJ; Rosenfield M
    Optom Vis Sci; 2015 Dec; 92(12):1133-9. PubMed ID: 26540478
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Accuracy and accommodation capability of a handheld autorefractor.
    Wesemann W; Dick B
    J Cataract Refract Surg; 2000 Jan; 26(1):62-70. PubMed ID: 10646148
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Screening for refractive errors in children: the plusoptiX S08 and the Retinomax K-plus2 performed by a lay screener compared to cycloplegic retinoscopy.
    Paff T; Oudesluys-Murphy AM; Wolterbeek R; Swart-van den Berg M; de Nie JM; Tijssen E; Schalij-Delfos NE
    J AAPOS; 2010 Dec; 14(6):478-83. PubMed ID: 21168070
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Reproducibility and accuracy of measurements with a hand held autorefractor in children.
    Harvey EM; Miller JM; Wagner LK; Dobson V
    Br J Ophthalmol; 1997 Nov; 81(11):941-8. PubMed ID: 9505815
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of the Plusoptix A09 and Retinomax K-Plus 3 with retinoscopy in children.
    Yilmaz I; Ozkaya A; Alkin Z; Ozbengi S; Yazici AT; Demirok A
    J Pediatr Ophthalmol Strabismus; 2015; 52(1):37-42. PubMed ID: 25643369
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Cycloplegic refraction in preschool children: comparisons between the hand-held autorefractor, table-mounted autorefractor and retinoscopy.
    Prabakaran S; Dirani M; Chia A; Gazzard G; Fan Q; Leo SW; Ling Y; Au Eong KG; Wong TY; Saw SM
    Ophthalmic Physiol Opt; 2009 Jul; 29(4):422-6. PubMed ID: 19523087
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Intra- and inter- examiner repeatability of cycloplegic retinoscopy among young children.
    McCullough SJ; Doyle L; Saunders KJ
    Ophthalmic Physiol Opt; 2017 Jan; 37(1):16-23. PubMed ID: 28030881
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A comparison of cycloplegic autorefraction and retinoscopy in Indian children.
    Guha S; Shah S; Shah K; Hurakadli P; Majee D; Gandhi S
    Clin Exp Optom; 2017 Jan; 100(1):73-78. PubMed ID: 27426488
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Accuracy of noncycloplegic autorefraction in school-age children in China.
    Zhao J; Mao J; Luo R; Li F; Pokharel GP; Ellwein LB
    Optom Vis Sci; 2004 Jan; 81(1):49-55. PubMed ID: 14747761
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Cycloplegic Autorefraction as a Substitute for Cycloplegic Retinoscopy in the Pediatric Population.
    Schott B; Seery C; Wagner RS; Guo S
    J Pediatr Ophthalmol Strabismus; 2022; 59(6):422-427. PubMed ID: 35446196
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of aberrometer and autorefractor measures of refractive error in children.
    Martinez AA; Pandian A; Sankaridurg P; Rose K; Huynh SC; Mitchell P
    Optom Vis Sci; 2006 Nov; 83(11):811-7. PubMed ID: 17106401
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A comparison of a traditional and wavefront autorefraction.
    Lebow KA; Campbell CE
    Optom Vis Sci; 2014 Oct; 91(10):1191-8. PubMed ID: 25198541
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Accuracy of a new photo-refractometer in young and adult patients.
    Schimitzek T; Lagrèze WA
    Graefes Arch Clin Exp Ophthalmol; 2005 Jul; 243(7):637-45. PubMed ID: 15650858
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.