These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 24935662)

  • 1. Comparison of outside-in and inside-out technique for tibial fixation of a soft-tissue graft in ACL reconstruction using the Shim technique.
    Lenschow S; Schliemann B; Schulze M; Raschke M; Kösters C
    Arch Orthop Trauma Surg; 2014 Sep; 134(9):1293-9. PubMed ID: 24935662
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Structural properties of a new fixation strategy in double bundle ACL reconstruction: the MiniShim.
    Lenschow S; Schliemann B; Dressler K; Zampogna B; Vasta S; Raschke M; Zantop T
    Arch Orthop Trauma Surg; 2011 Aug; 131(8):1159-65. PubMed ID: 21667178
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique.
    Lenschow S; Herbort M; Strässer A; Strobel M; Raschke M; Petersen W; Zantop T
    Arch Orthop Trauma Surg; 2011 Aug; 131(8):1067-72. PubMed ID: 21331547
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of 2 anterior cruciate ligament graft preparation techniques for tibial fixation: adjustable-length loop cortical button or interference screw.
    Mayr R; Heinrichs CH; Eichinger M; Coppola C; Schmoelz W; Attal R
    Am J Sports Med; 2015 Jun; 43(6):1380-5. PubMed ID: 25767269
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of interference screws and combination screw and sheath devices for soft tissue anterior cruciate ligament reconstruction on the tibial side.
    Aga C; Rasmussen MT; Smith SD; Jansson KS; LaPrade RF; Engebretsen L; Wijdicks CA
    Am J Sports Med; 2013 Apr; 41(4):841-8. PubMed ID: 23404085
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical Testing of Three Alternative Quadrupled Tendon Graft Constructs With Adjustable Loop Suspensory Fixation for Anterior Cruciate Ligament Reconstruction Compared With Four-Strand Grafts Fixed With Screws and Femoral Fixed Loop Devices.
    Vertullo CJ; Piepenbrink M; Smith PA; Wilson AJ; Wijdicks CA
    Am J Sports Med; 2019 Mar; 47(4):828-836. PubMed ID: 30789779
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interference screw fixation of doubled flexor tendon graft in anterior cruciate ligament reconstruction - biomechanical evaluation with cyclic elongation.
    Nakano H; Yasuda K; Tohyama H; Yamanaka M; Wada T; Kaneda K
    Clin Biomech (Bristol, Avon); 2000 Mar; 15(3):188-95. PubMed ID: 10656980
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Screw oversizing for anterior cruciate ligament graft fixation in primary and enlarged tibial tunnels: A biomechanical study in a porcine model.
    Eichinger M; Schmoelz W; Attal R; Moroder A; Heinrichs CH; Smekal V; Mayr R
    Knee; 2018 Oct; 25(5):774-781. PubMed ID: 29887246
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of tunnel dilation and interference screw position on the biomechanical properties of tendon graft fixation for anterior cruciate ligament reconstruction.
    Higano M; Tachibana Y; Sakaguchi K; Goto T; Oda H
    Arthroscopy; 2013 Nov; 29(11):1804-10. PubMed ID: 24011556
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anterior Cruciate Ligament Soft Tissue Graft Fixation in the Elderly: Is There a Reason to Use Interference Screws? A Human Cadaver Study.
    Domnick C; Herbort M; Raschke MJ; Habermann S; Schliemann B; Petersen W; Weimann A
    Arthroscopy; 2017 Sep; 33(9):1694-1700. PubMed ID: 28499921
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Femoral interference screw fixation of hamstring and quadriceps tendons for ACL reconstruction.
    Ettinger M; Werner-Lebeda T; Calliess T; Omar M; Becher C; Ezechieli M; Klintschar M; Petri M
    Knee Surg Sports Traumatol Arthrosc; 2017 Apr; 25(4):1241-1248. PubMed ID: 26818555
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In situ comparison of varying composite tibial tunnel interference screws used for ACL soft tissue graft fixation.
    Nyland J; Krupp R; Greene J; Bowles R; Burden R; Caborn DN
    Knee; 2015 Dec; 22(6):554-8. PubMed ID: 26092113
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accidental perforation of the lateral femoral cortex in ACL reconstruction: an investigation of mechanical properties of different fixation techniques.
    Herbort M; Heletta S; Raschke MJ; Schliemann B; Osada N; Petersen W; Zantop T
    Arthroscopy; 2012 Mar; 28(3):382-9. PubMed ID: 22305326
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evolgate fixation of doubled flexor graft in anterior cruciate ligament reconstruction: biomechanical evaluation with cyclic loading.
    Ferretti A; Conteduca F; Labianca L; Monaco E; De Carli A
    Am J Sports Med; 2005 Apr; 33(4):574-82. PubMed ID: 15788732
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of interference screw fixation on ACL graft tensile strength.
    Sawyer GA; Anderson BC; Paller D; Heard WM; Fadale PD
    J Knee Surg; 2013 Jun; 26(3):155-9. PubMed ID: 23288751
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tibial Fixation Properties of a Continuous-Loop ACL Hamstring Graft Construct with Suspensory Fixation in Porcine Bone.
    Smith PA; DeBerardino TM
    J Knee Surg; 2015 Dec; 28(6):506-12. PubMed ID: 25347056
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction: a biomechanical study in a porcine model.
    Walsh MP; Wijdicks CA; Parker JB; Hapa O; LaPrade RF
    Am J Sports Med; 2009 Jan; 37(1):160-7. PubMed ID: 18832342
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical comparison of hamstring tendon fixation devices for anterior cruciate ligament reconstruction: Part 2. Four tibial devices.
    Scannell BP; Loeffler BJ; Hoenig M; Peindl RD; D'Alessandro DF; Connor PM; Fleischli JE
    Am J Orthop (Belle Mead NJ); 2015 Feb; 44(2):82-5. PubMed ID: 25658077
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pullout strength of a novel hybrid fixation technique (Tape Locking Screw™) in soft-tissue ACL reconstruction: A biomechanical study in human and porcine bone.
    Ayzenberg M; Arango D; Gershkovich GE; Samuel PS; Saing M
    Orthop Traumatol Surg Res; 2017 Jun; 103(4):591-595. PubMed ID: 28238964
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of Different Tibial Fixation Techniques on Initial Stability in Single-Stage Anterior Cruciate Ligament Revision With Confluent Tibial Tunnels: A Biomechanical Laboratory Study.
    Schliemann B; Treder M; Schulze M; Müller V; Vasta S; Zampogna B; Herbort M; Kösters C; Raschke MJ; Lenschow S
    Arthroscopy; 2016 Jan; 32(1):78-89. PubMed ID: 26372523
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.