190 related articles for article (PubMed ID: 24949407)
1. Basic technique in endoscopic ultrasound-guided fine needle aspiration for solid lesions: How many passes?
Petrone MC; Arcidiacono PG
Endosc Ultrasound; 2014 Jan; 3(1):22-7. PubMed ID: 24949407
[TBL] [Abstract][Full Text] [Related]
2. Endoscopic ultrasound-guided tissue acquisition with or without rapid on-site evaluation for solid pancreatic lesions: five years of experience from a single center.
Liu Y; Xiong D; Zhao Y; Meng Z; Wu X; Jiang Q; Wang Q; Wu D; Zhang S; Feng Y; Yang A
Scand J Gastroenterol; 2023; 58(10):1185-1193. PubMed ID: 37114616
[TBL] [Abstract][Full Text] [Related]
3. Endoscopic ultrasound (EUS)-guided fine needle biopsy alone vs. EUS-guided fine needle aspiration with rapid onsite evaluation in pancreatic lesions: a multicenter randomized trial.
Chen YI; Chatterjee A; Berger R; Kanber Y; Wyse J; Lam E; Gan I; Auger M; Kenshil S; Telford J; Donnellan F; Quinlan J; Lutzak G; Alshamsi F; Parent J; Waschke K; Alghamdi A; Barkun J; Metrakos P; Chaudhury P; Martel M; Dorreen A; Candido K; Miller C; Adam V; Barkun A; Zogopoulos G; Wong C
Endoscopy; 2022 Jan; 54(1):4-12. PubMed ID: 33506455
[TBL] [Abstract][Full Text] [Related]
4. Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study.
Wong T; Pattarapuntakul T; Netinatsunton N; Ovartlarnporn B; Sottisuporn J; Chamroonkul N; Sripongpun P; Jandee S; Kaewdech A; Attasaranya S; Piratvisuth T
World J Surg Oncol; 2022 Jun; 20(1):215. PubMed ID: 35751053
[TBL] [Abstract][Full Text] [Related]
5. Increasing Number of Passes Beyond 4 Does Not Increase Sensitivity of Detection of Pancreatic Malignancy by Endoscopic Ultrasound-Guided Fine-Needle Aspiration.
Mohamadnejad M; Mullady D; Early DS; Collins B; Marshall C; Sams S; Yen R; Rizeq M; Romanas M; Nawaz S; Ulusarac O; Hollander T; Wilson RH; Simon VC; Kushnir V; Amateau SK; Brauer BC; Gaddam S; Azar RR; Komanduri S; Shah R; Das A; Edmundowicz S; Muthusamy VR; Rastogi A; Wani S
Clin Gastroenterol Hepatol; 2017 Jul; 15(7):1071-1078.e2. PubMed ID: 28025154
[TBL] [Abstract][Full Text] [Related]
6. Randomized Noninferiority Trial Comparing Diagnostic Yield of Cytopathologist-guided versus 7 passes for EUS-FNA of Pancreatic Masses.
Lee LS; Nieto J; Watson RR; Hwang AL; Muthusamy VR; Walter L; Jajoo K; Ryou MK; Saltzman JR; Saunders MD; Suleiman S; Kadiyala V
Dig Endosc; 2016 May; 28(4):469-475. PubMed ID: 26694852
[TBL] [Abstract][Full Text] [Related]
7. Touch imprint cytology on endoscopic ultrasound fine-needle biopsy provides comparable sample quality and diagnostic yield to standard endoscopic ultrasound fine-needle aspiration specimens in the evaluation of solid pancreatic lesions.
Crinò SF; Larghi A; Bernardoni L; Parisi A; Frulloni L; Gabbrielli A; Parcesepe P; Scarpa A; Manfrin E
Cytopathology; 2019 Mar; 30(2):179-186. PubMed ID: 30484917
[TBL] [Abstract][Full Text] [Related]
8. Endoscopic ultrasound guided fine-needle aspiration of lymph nodes and solid masses: factors influencing the cellularity and adequacy of the aspirate.
Wee E; Lakhtakia S; Gupta R; Sekaran A; Kalapala R; Monga A; Arjunan S; Reddy DN
J Clin Gastroenterol; 2012 Jul; 46(6):487-93. PubMed ID: 22688144
[TBL] [Abstract][Full Text] [Related]
9. Rapid On-Site Evaluation by Endosonographers during Endoscopic Ultrasonography-Guided Fine-Needle Aspiration for Diagnosis of Gastrointestinal Stromal Tumors.
Tamura T; Yamashita Y; Ueda K; Kawaji Y; Itonaga M; Murata SI; Yamamoto K; Yoshida T; Maeda H; Maekita T; Iguchi M; Tamai H; Ichinose M; Kato J
Clin Endosc; 2017 Jul; 50(4):372-378. PubMed ID: 28103654
[TBL] [Abstract][Full Text] [Related]
10. Factors Influencing the Diagnostic Performance of Repeat Endoscopic Ultrasound-Guided Fine-Needle Aspiration/Biopsy after the First Inconclusive Diagnosis of Pancreatic Solid Lesions.
Cho JH; Kim J; Lee HS; Ryu SJ; Jang SI; Kim EJ; Kang H; Lee SS; Song TJ; Bang S
Gut Liver; 2024 Jan; 18(1):184-191. PubMed ID: 37317559
[TBL] [Abstract][Full Text] [Related]
11. Endoscopic ultrasonography-fine needle aspiration of solid pancreatic masses: Do we need the fourth pass? A prospective study.
Teodorescu C; Gheorghiu M; Zaharie T; Rusu I; Pojoga C; Bolboacă SD; Seicean R; Petrusel L; Seicean A
Diagn Cytopathol; 2021 Mar; 49(3):395-403. PubMed ID: 33220130
[TBL] [Abstract][Full Text] [Related]
12. Diagnostic value of endoscopic ultrasound-guided fine needle aspiration with rapid on-site evaluation performed by endoscopists in solid pancreatic lesions: A prospective, randomized controlled trial.
Zhang S; Ni M; Wang P; Zheng J; Sun Q; Xu G; Peng C; Shen S; Zhang W; Huang S; Wang L; Zou X; Lv Y
J Gastroenterol Hepatol; 2022 Oct; 37(10):1975-1982. PubMed ID: 35614028
[TBL] [Abstract][Full Text] [Related]
13. High-resolution endoscopic ultrasound imaging and the number of needle passages are significant factors predicting high yield of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid masses without an on-site cytopathologist.
Jeong SH; Yoon HH; Kim EJ; Kim YJ; Kim YS; Cho JH
Medicine (Baltimore); 2017 Jan; 96(2):e5782. PubMed ID: 28079803
[TBL] [Abstract][Full Text] [Related]
14. A Comparative Study of the Diagnostic Utility of Endoscopic Ultrasound-Guided Fine Needle Aspiration Cytology (EUS-FNA) versus Endoscopic Ultrasound-Guided Fine Needle Biopsy (EUS-FNB) in Pancreatic and Non-Pancreatic Lesions.
Yousri M; Abusinna E; Tahoun N; Okasha HH; El-Habashi AH
Asian Pac J Cancer Prev; 2022 Jun; 23(6):2151-2158. PubMed ID: 35763660
[TBL] [Abstract][Full Text] [Related]
15. Relationship of pancreatic mass size and diagnostic yield of endoscopic ultrasound-guided fine needle aspiration.
Siddiqui AA; Brown LJ; Hong SK; Draganova-Tacheva RA; Korenblit J; Loren DE; Kowalski TE; Solomides C
Dig Dis Sci; 2011 Nov; 56(11):3370-5. PubMed ID: 21688127
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of endoscopic ultrasound fine-needle aspiration versus fine-needle biopsy and impact of rapid on-site evaluation for pancreatic masses.
de Moura DTH; McCarty TR; Jirapinyo P; Ribeiro IB; Hathorn KE; Madruga-Neto AC; Lee LS; Thompson CC
Endosc Int Open; 2020 Jun; 8(6):E738-E747. PubMed ID: 32490158
[No Abstract] [Full Text] [Related]
17. EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study.
Kandel P; Tranesh G; Nassar A; Bingham R; Raimondo M; Woodward TA; Gomez V; Wallace MB
Gastrointest Endosc; 2016 Dec; 84(6):1034-1039. PubMed ID: 27018087
[TBL] [Abstract][Full Text] [Related]
18. Endoscopic ultrasound with combined fine needle aspiration plus biopsy improves diagnostic yield in solid pancreatic masses.
Gonzalez A; Wadhwa V; Singh H; Khan S; Gupta K; Liang H; Hussain I; Vargo J; Jang S; Chahal P; Bhatt A; Siddiki H; Erim T; Sanaka MR
Scand J Gastroenterol; 2022 May; 57(5):610-617. PubMed ID: 34991430
[TBL] [Abstract][Full Text] [Related]
19. Endoscopic ultrasonography-guided fine needle aspiration: Relatively low sensitivity in the endosonographer population.
Dumonceau JM; Koessler T; van Hooft JE; Fockens P
World J Gastroenterol; 2012 May; 18(19):2357-63. PubMed ID: 22654426
[TBL] [Abstract][Full Text] [Related]
20. Comparison of tissue and molecular yield between fine-needle biopsy (FNB) and fine-needle aspiration (FNA): a randomized study.
Asokkumar R; Yung Ka C; Loh T; Kah Ling L; Gek San T; Ying H; Tan D; Khor C; Lim T; Soetikno R
Endosc Int Open; 2019 Aug; 7(8):E955-E963. PubMed ID: 31367675
[No Abstract] [Full Text] [Related]
[Next] [New Search]