These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 24949416)

  • 21. Arterial spin-labeled perfusion combined with segmentation techniques to evaluate cerebral blood flow in white and gray matter of children with sickle cell anemia.
    Helton KJ; Paydar A; Glass J; Weirich EM; Hankins J; Li CS; Smeltzer MP; Wang WC; Ware RE; Ogg RJ
    Pediatr Blood Cancer; 2009 Jan; 52(1):85-91. PubMed ID: 18937311
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Arterial spin labeling magnetic resonance perfusion study to evaluate the effects of age and gender on normal cerebral blood flow.
    Soni N; Jain A; Kumar S; Pandey CM; Awasthi A
    Neurol India; 2016; 64 Suppl():S32-8. PubMed ID: 26954965
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of long-labeled pseudo-continuous arterial spin labeling (ASL) features between young and elderly adults: special reference to parameter selection.
    Fujiwara Y; Matsuda T; Kanamoto M; Tsuchida T; Tsuji K; Kosaka N; Adachi T; Kimura H
    Acta Radiol; 2017 Jan; 58(1):84-90. PubMed ID: 26893213
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effects of systematic partial volume errors on the estimation of gray matter cerebral blood flow with arterial spin labeling MRI.
    Petr J; Mutsaerts HJMM; De Vita E; Steketee RME; Smits M; Nederveen AJ; Hofheinz F; van den Hoff J; Asllani I
    MAGMA; 2018 Dec; 31(6):725-734. PubMed ID: 29916058
    [TBL] [Abstract][Full Text] [Related]  

  • 25. In vivo visualization of the PICA perfusion territory with super-selective pseudo-continuous arterial spin labeling MRI.
    Hartkamp NS; De Cocker LJ; Helle M; van Osch MJ; Kappelle LJ; Bokkers RP; Hendrikse J
    Neuroimage; 2013 Dec; 83():58-65. PubMed ID: 23820436
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Test-retest reproducibility of quantitative CBF measurements using FAIR perfusion MRI and acetazolamide challenge.
    Yen YF; Field AS; Martin EM; Ari N; Burdette JH; Moody DM; Takahashi AM
    Magn Reson Med; 2002 May; 47(5):921-8. PubMed ID: 11979571
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Characterizing the white matter hyperintensity penumbra with cerebral blood flow measures.
    Promjunyakul N; Lahna D; Kaye JA; Dodge HH; Erten-Lyons D; Rooney WD; Silbert LC
    Neuroimage Clin; 2015; 8():224-9. PubMed ID: 26106546
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Robust method for 3D arterial spin labeling in mice.
    Chugh BP; Bishop J; Zhou YQ; Wu J; Henkelman RM; Sled JG
    Magn Reson Med; 2012 Jul; 68(1):98-106. PubMed ID: 22102489
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Pseudo-continuous arterial spin labeling quantifies cerebral blood flow in patients with acute ischemic stroke and chronic lacunar stroke.
    Guo L; Zhang Q; Ding L; Liu K; Ding K; Jiang C; Liu C; Li K; Cui L
    Clin Neurol Neurosurg; 2014 Oct; 125():229-36. PubMed ID: 25203634
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Increased resting cerebral blood flow in adult Fabry disease: MRI arterial spin labeling study.
    Phyu P; Merwick A; Davagnanam I; Bolsover F; Jichi F; Wheeler-Kingshott C; Golay X; Hughes D; Cipolotti L; Murphy E; Lachmann RH; Werring DJ
    Neurology; 2018 Apr; 90(16):e1379-e1385. PubMed ID: 29661900
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Cerebral blood flow measured by arterial-spin labeling MRI: a useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis.
    Zheng G; Zhang LJ; Zhong J; Wang Z; Qi R; Shi D; Lu GM
    Eur J Radiol; 2013 Nov; 82(11):1981-8. PubMed ID: 23849331
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Quantitative cerebral perfusion imaging in children and young adults with Moyamoya disease: comparison of arterial spin-labeling-MRI and H(2)[(15)O]-PET.
    Goetti R; Warnock G; Kuhn FP; Guggenberger R; O'Gorman R; Buck A; Khan N; Scheer I
    AJNR Am J Neuroradiol; 2014 May; 35(5):1022-8. PubMed ID: 24335546
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Absolute quantification of perfusion by dynamic susceptibility contrast MRI using Bookend and VASO steady-state CBV calibration: a comparison with pseudo-continuous ASL.
    Lindgren E; Wirestam R; Markenroth Bloch K; Ahlgren A; van Osch MJ; van Westen D; Surova Y; Ståhlberg F; Knutsson L
    MAGMA; 2014 Dec; 27(6):487-99. PubMed ID: 24570336
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Validation study of a pulsed arterial spin labeling technique by comparison to perfusion computed tomography.
    Koziak AM; Winter J; Lee TY; Thompson RT; St Lawrence KS
    Magn Reson Imaging; 2008 May; 26(4):543-53. PubMed ID: 18063336
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Measurement of brain perfusion in newborns: pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL).
    Boudes E; Gilbert G; Leppert IR; Tan X; Pike GB; Saint-Martin C; Wintermark P
    Neuroimage Clin; 2014; 6():126-33. PubMed ID: 25379424
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Unilateral fetal-type circle of Willis anatomy causes right-left asymmetry in cerebral blood flow with pseudo-continuous arterial spin labeling: A limitation of arterial spin labeling-based cerebral blood flow measurements?
    Barkeij Wolf JJH; Foster-Dingley JC; Moonen JEF; van Osch MJP; de Craen AJM; de Ruijter W; van der Mast RC; van der Grond J
    J Cereb Blood Flow Metab; 2016 Sep; 36(9):1570-8. PubMed ID: 26755444
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Different patterns of cerebral perfusion in SLE patients with and without neuropsychiatric manifestations.
    Zhuo Z; Su L; Duan Y; Huang J; Qiu X; Haller S; Li H; Zeng X; Liu Y
    Hum Brain Mapp; 2020 Feb; 41(3):755-766. PubMed ID: 31650651
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of velocity- and acceleration-selective arterial spin labeling with [15O]H2O positron emission tomography.
    Schmid S; Heijtel DF; Mutsaerts HJ; Boellaard R; Lammertsma AA; Nederveen AJ; van Osch MJ
    J Cereb Blood Flow Metab; 2015 Aug; 35(8):1296-303. PubMed ID: 25785831
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Hemilaterally masked arterial spin labeling by intentional magnetic field changes in the labeling area due to placement of material with high susceptibility.
    Hagiwara H; Nakajima Y; Ikegami T; Kinno Y; Kumada M
    PLoS One; 2018; 13(7):e0200648. PubMed ID: 30001396
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Cerebral vascular response to hypercapnia: determination with perfusion MRI at 1.5 and 3.0 Tesla using a pulsed arterial spin labeling technique.
    Nöth U; Meadows GE; Kotajima F; Deichmann R; Corfield DR; Turner R
    J Magn Reson Imaging; 2006 Dec; 24(6):1229-35. PubMed ID: 17094105
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.