BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

695 related articles for article (PubMed ID: 24954252)

  • 1. Accuracy of pedicle screw placement in the thoracic and lumbosacral spine using a conventional intraoperative fluoroscopy-guided technique: a national neurosurgical education and training center analysis of 1236 consecutive screws.
    Nevzati E; Marbacher S; Soleman J; Perrig WN; Diepers M; Khamis A; Fandino J
    World Neurosurg; 2014 Nov; 82(5):866-71.e1-2. PubMed ID: 24954252
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of fluoroscopically-assisted pedicle screw placement: analysis of 1,218 screws in 198 patients.
    Koktekir E; Ceylan D; Tatarli N; Karabagli H; Recber F; Akdemir G
    Spine J; 2014 Aug; 14(8):1702-8. PubMed ID: 24704680
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Percutaneous "K-wireless" pedicle screw fixation technique: an evaluation of the initial experience of 100 screws with assessment of accuracy, radiation exposure, and procedure time.
    Spitz SM; Sandhu FA; Voyadzis JM
    J Neurosurg Spine; 2015 Apr; 22(4):422-31. PubMed ID: 25658468
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Does Navigation Improve Pedicle Screw Placement Accuracy? Comparison Between Navigated and Non-navigated Percutaneous and Open Fixations.
    Innocenzi G; Bistazzoni S; D'Ercole M; Cardarelli G; Ricciardi F
    Acta Neurochir Suppl; 2017; 124():289-295. PubMed ID: 28120086
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine: accuracy and complication rates.
    Raley DA; Mobbs RJ
    Spine (Phila Pa 1976); 2012 May; 37(12):1092-100. PubMed ID: 22037528
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Lumbosacral pedicle screw placement using a fluoroscopic pedicle axis view and a cannulated tapping device.
    Yoshii T; Hirai T; Yamada T; Sumiya S; Mastumoto R; Kato T; Enomoto M; Inose H; Kawabata S; Shinomiya K; Okawa A
    J Orthop Surg Res; 2015 May; 10():79. PubMed ID: 26016564
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Robotic versus fluoroscopy-guided pedicle screw insertion for metastatic spinal disease: a matched-cohort comparison.
    Solomiichuk V; Fleischhammer J; Molliqaj G; Warda J; Alaid A; von Eckardstein K; Schaller K; Tessitore E; Rohde V; Schatlo B
    Neurosurg Focus; 2017 May; 42(5):E13. PubMed ID: 28463620
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients.
    Amato V; Giannachi L; Irace C; Corona C
    J Neurosurg Spine; 2010 Mar; 12(3):306-13. PubMed ID: 20192632
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Incidence and clinical significance of vascular encroachment resulting from freehand placement of pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws.
    Parker SL; Amin AG; Santiago-Dieppa D; Liauw JA; Bydon A; Sciubba DM; Wolinsky JP; Gokaslan ZL; Witham TF
    Spine (Phila Pa 1976); 2014 Apr; 39(8):683-7. PubMed ID: 24480963
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accurate pedicle screw placement--a perspective statement.
    Gerard CS; Fessler RG
    World Neurosurg; 2015 May; 83(5):747-9. PubMed ID: 25238678
    [No Abstract]   [Full Text] [Related]  

  • 11. Are pedicle screws dangerous?
    Fogelson JL; Krauss WE
    World Neurosurg; 2015 May; 83(5):744-6. PubMed ID: 25238680
    [No Abstract]   [Full Text] [Related]  

  • 12. Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery.
    Nakashima H; Sato K; Ando T; Inoh H; Nakamura H
    J Spinal Disord Tech; 2009 Oct; 22(7):468-72. PubMed ID: 20075808
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery.
    Tormenti MJ; Kostov DB; Gardner PA; Kanter AS; Spiro RM; Okonkwo DO
    Neurosurg Focus; 2010 Mar; 28(3):E11. PubMed ID: 20192656
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of pedicle screw placement in thoracolumbar spine with conventional open technique.
    Borcek AO; Suner HI; Emmez H; Kaymaz M; Aykol S; Pasaoglu A
    Turk Neurosurg; 2014; 24(3):398-402. PubMed ID: 24848181
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Inserting pedicle screws in the upper thoracic spine without the use of fluoroscopy or image guidance. Is it safe?
    Schizas C; Theumann N; Kosmopoulos V
    Eur Spine J; 2007 May; 16(5):625-9. PubMed ID: 17106663
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Percutaneous pedicle screw placement under single dimensional fluoroscopy with a designed pedicle finder-a technical note and case series.
    Tsuang FY; Chen CH; Kuo YJ; Tseng WL; Chen YS; Lin CJ; Liao CJ; Lin FH; Chiang CJ
    Spine J; 2017 Sep; 17(9):1373-1380. PubMed ID: 28645672
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications.
    Carbone JJ; Tortolani PJ; Quartararo LG
    Spine (Phila Pa 1976); 2003 Jan; 28(1):91-7. PubMed ID: 12544964
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Learning curve of 3D fluoroscopy image-guided pedicle screw placement in the thoracolumbar spine.
    Ryang YM; Villard J; Obermüller T; Friedrich B; Wolf P; Gempt J; Ringel F; Meyer B
    Spine J; 2015 Mar; 15(3):467-76. PubMed ID: 25315133
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prospective Comparison Study Between the Fluoroscopy-guided and Navigation Coupled With O-arm-guided Pedicle Screw Placement in the Thoracic and Lumbosacral Spines.
    Shin MH; Hur JW; Ryu KS; Park CK
    J Spinal Disord Tech; 2015 Jul; 28(6):E347-51. PubMed ID: 23563342
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique.
    Modi HN; Suh SW; Fernandez H; Yang JH; Song HR
    Eur Spine J; 2008 Dec; 17(12):1686-96. PubMed ID: 18830636
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 35.