These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 2495812)

  • 21. Early detection of "rebreathing" in afferent and efferent reservoir breathing systems using capnography.
    Miller DM
    Br J Anaesth; 1990 Feb; 64(2):251-5. PubMed ID: 2107865
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Carbon dioxide elimination during spontaneous ventilation with a modified Mapleson D system: studies in a lung model.
    Rose DK; Byrick RJ; Froese AB
    Can Anaesth Soc J; 1978 Sep; 25(5):353-65. PubMed ID: 279390
    [No Abstract]   [Full Text] [Related]  

  • 23. Critical evaluation of emergency stockpile ventilators in an in vitro model of pediatric lung injury.
    Custer JW; Watson CM; Dwyer J; Kaczka DW; Simon BA; Easley RB
    Pediatr Crit Care Med; 2011 Nov; 12(6):e357-61. PubMed ID: 21317679
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator].
    Schirmer U; Villwock J; Fösel T; Schreiber M; Goertz A; Georgieff M
    Anaesthesist; 1992 Dec; 41(12):785-9. PubMed ID: 1489078
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The importance of the expiratory pause. Comparison of the Mapleson A, C and D breathing systems using a lung model.
    Cook LB
    Anaesthesia; 1996 May; 51(5):453-60. PubMed ID: 8694159
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of inspiratory flow rate on the efficiency of carbon dioxide removal at tidal volumes below instrumental dead space.
    Hurley EH; Keszler M
    Arch Dis Child Fetal Neonatal Ed; 2017 Mar; 102(2):F126-F130. PubMed ID: 27515984
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measuring rebreathing in spontaneous ventilation. A new lung model.
    Cook LB; Watt S; Peachey G; Chakrabarti MK
    Anaesthesia; 1996 Mar; 51(3):241-6. PubMed ID: 8712324
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Efficiency of breathing systems A and D in the Carden Ventmasta ventilator.
    Tham EJ; Davies R; Slade JM; Mapleson WW
    Br J Anaesth; 1993 Nov; 71(5):741-6. PubMed ID: 8251292
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The MultiCircuit System. 2. A study during spontaneous ventilation in awake volunteers using the Mapleson A mode.
    Bradley JP; Marsland AR; Massang JR
    Anaesth Intensive Care; 1985 May; 13(2):158-62. PubMed ID: 3860022
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Lung aeration during ventilation after recruitment guided by tidal elimination of carbon dioxide and dynamic compliance was better than after end-tidal carbon dioxide targeted ventilation: a computed tomography study in surfactant-depleted piglets.
    Hanson A; Göthberg S; Nilsson K; Hedenstierna G
    Pediatr Crit Care Med; 2011 Nov; 12(6):e362-8. PubMed ID: 21263364
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Enclosed afferent reservoir breathing systems. Description and clinical evaluation.
    Miller DM; Miller JC
    Br J Anaesth; 1988 Mar; 60(4):469-75. PubMed ID: 3128319
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Universal coaxial anesthetic system].
    Ungerer MJ; le Roux FP
    S Afr Med J; 1978 Feb; 53(8):287-9. PubMed ID: 653532
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Effect of Pressure-Controlled Ventilation and Volume-Controlled Ventilation in Prone Position on Pulmonary Mechanics and Inflammatory Markers.
    Şenay H; Sıvacı R; Kokulu S; Koca B; Bakı ED; Ela Y
    Inflammation; 2016 Aug; 39(4):1469-74. PubMed ID: 27221140
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Regulation of respiration in assisted ventilation].
    Waurick S; König F
    Anaesthesist; 1984 Feb; 33(2):89-95. PubMed ID: 6424497
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An evaluation of the Samson and Magill (Mapleson A) circuits during anaesthesia.
    Moyes DG; Klein MT
    S Afr Med J; 1981 Oct; 60(16):621-3. PubMed ID: 6794158
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Respiratory pattern and rebreathing in the Mapleson A, C and D breathing systems with spontaneous ventilation. A theory.
    Cook LB
    Anaesthesia; 1996 Apr; 51(4):371-85. PubMed ID: 8686829
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Capnography and the Bain circuit I: A computer model.
    Beneken JE; Gravenstein N; Gravenstein JS; van der Aa JJ; Lampotang S
    J Clin Monit; 1985 Apr; 1(2):103-13. PubMed ID: 3938477
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Clinical comparison of the Bain and Magill anaesthetic systems during spontaneous respiration.
    Alexander JP
    Br J Anaesth; 1982 Oct; 54(10):1031-6. PubMed ID: 6812605
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A new active model lung.
    Damia G; Cigada M; Solca M; Pelizzola A
    Intensive Care Med; 1988; 14(1):60-3. PubMed ID: 3422659
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Pressure support and pressure assist/control: are there differences? An evaluation of the newest intensive care unit ventilators.
    Williams P; Kratohvil J; Ritz R; Hess DR; Kacmarek RM
    Respir Care; 2000 Oct; 45(10):1169-81. PubMed ID: 11054896
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.